DX8200A REFERENCE MANUAL
14
2
2.2 MECHANICAL MOUNTING
2.2.1 Mounting the Scanner
DX8200A can be installed to operate in any position. There are 4 slots (dia. 8.5 mm) on the
sides of the scanner for mounting. The diagram below can be used for installation; refer to par.
9.4 for correct positioning of the scanner with respect to the reading zone and scanner
orient
ation. See par. "Scanner Direction" for scanner direction relative to the conveyor.
470
[18.50]
300
[11.81]
==
180
[7.09]
22
[0.87]
406
[15.98]
22
[0.87]
8.5
[0.33]
141
[5.55]
147
[5.79]
10
[0.39]
370
[14.57]
==
370
[14.57]
= =
==
60.5
[2.38]
70.5
[2.78]
N° 4
Figure 5- DX8200A Overall Dimensions