Datalogic POWERSCAN HD Specifikace Strana 176

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 212
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 175
POWERSCAN
®
D8330/M8300
168
5.14.3 Copy BC-80X0
Procedure
:
c
Using the slave reader and its BC-80X0 cradle, read the Restore Default
barcode, set the radio address, and then read the RS-232 interface barcode
from chapter 4 of this manual or from the Quick Reference Guide.
d
Connect the master BC-80X0 and the slave BC-80X0 (cradle to be configured)
together through two RS-232 serial interface cables and external power supply.
Accessory cables and power supply are available from your Datalogic
distributor to provide this connection.
RS-232 Cables: CAB471 & CAB472
Power Supply: PG12
e
Read the Configuration Copy barcode below with a reader. Then place it onto
the master BC-80X0 cradle.
Copy Configuration
Ì$+ZZ3$-9Î
The configuration will be copied from the master BC-80X0 to the slave
BC-80X0. The reader signals the end of the procedure with a series of beeps.
f
Repeat the procedure above to configure other slave cradles.
Note: The master BC-80X0 can be configured for any interface.
Zobrazit stránku 175
1 2 ... 171 172 173 174 175 176 177 178 179 180 181 ... 211 212

Komentáře k této Příručce

Žádné komentáře