Strany 1 - PowerScan™ 9500 Family

PowerScan™ 9500 FamilyProduct Reference GuideIndustrial Corded Handheld Area Imager Bar Code ReaderPowerScan PD9530/PBT9500/PM9500

Strany 2 -

ContentsviiiPowerScan™ PD9530/PBT9500/PM9500Set Key Sequence Header ...

Strany 3 - Table of Contents

Enter/Exit Programming Mode90PowerScan™ PD9530/PBT9500/PM9500EAN 13 (JAN 13)The following options apply to the EAN 13 (Jan 13) symbology.EAN 13 Enable

Strany 4

Enter/Exit Programming ModeProduct Reference Guide 91EAN-13 Flag 1 CharacterEnables/disables transmission of an EAN/JAN13 F

Strany 5 - Product Reference Guide

Enter/Exit Programming Mode92PowerScan™ PD9530/PBT9500/PM9500EAN-13 2D ComponentThis feature enables/disables a requirement that a 2D label component

Strany 6

Enter/Exit Programming ModeProduct Reference Guide 93EAN 8 (JAN 8)The following options apply to the EAN 8 (Jan 8) symbolog

Strany 7

Enter/Exit Programming Mode94PowerScan™ PD9530/PBT9500/PM9500Expand EAN 8 to EAN 13Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13.DE

Strany 8

Enter/Exit Programming ModeProduct Reference Guide 95UPC/EAN GLOBAL SETTINGSThis section provides configuration settings fo

Strany 9

Enter/Exit Programming Mode96PowerScan™ PD9530/PBT9500/PM9500UPC/EAN Quiet ZonesThis feature specifies the number of quiet zones for UPC/EAN labels. Q

Strany 10 - Contents

Enter/Exit Programming ModeProduct Reference Guide 97ADD-ONSContact Customer Support for advanced programming of optional a

Strany 11 - Introduction

Enter/Exit Programming Mode98PowerScan™ PD9530/PBT9500/PM9500Optional Add-On TimerThis option sets the time the reader will look for an add-on when an

Strany 12 - Technical Support

$CADOT0C(CR)Optional Add-on Timer = 120ms$CADOT0E(CR)Optional Add-on Timer = 140ms$CADOT10(CR)Optional Add-on Timer = 160ms$CADOT12(CR)Optional Add-on

Strany 13 - About the Reader

Product Reference Guide 1Chapter 1IntroductionAbout this ManualThis Product Reference Guide (PRG) is provided for users see

Strany 14 - Table 1. LED Status

$CADOT1C(CR)Optional Add-on Timer = 280ms$CADOT1E(CR)Optional Add-on Timer = 300msEnter/Exit Programming Mode100PowerScan™ PD9530/PBT9500/PM9500Option

Strany 15 - Battery Safety

Enter/Exit Programming ModeProduct Reference Guide 101Optional GS1-128 Add-On Timer (continued)$CADUT04(CR)Optional GS1-128

Strany 16 - Programming the Reader

$CADUT12(CR)Optional GS1-128 Add-On Timer = 180ms$CADUT14(CR)Optional GS1-128 Add-On Timer = 200ms$CADUT16(CR)Optional GS1-128 Add-On Timer = 220ms$CA

Strany 17 - Chapter 2

Enter/Exit Programming ModeProduct Reference Guide 103CODE 39The following options apply to the Code 39 symbology.Code 39 E

Strany 18 - D. Connector Holder

Enter/Exit Programming Mode104PowerScan™ PD9530/PBT9500/PM9500Code 39 Check Character TransmissionEnable this option to transmit the check character a

Strany 19 - Mounting the BC9xx0 Cradle

Enter/Exit Programming ModeProduct Reference Guide 105Code 39 Start/Stop Character TransmissionEnable this option to enable

Strany 20 - Permanent Mounting

Enter/Exit Programming Mode106PowerScan™ PD9530/PBT9500/PM9500Code 39 Quiet ZonesThis feature specifies the number of quiet zones for Code 39 labels.

Strany 21 - Mounting for Portable Use

Enter/Exit Programming ModeProduct Reference Guide 107Code 39 Set Length 1This feature specifies one of the bar code length

Strany 22 - Base with Mount attached

Enter/Exit Programming Mode108PowerScan™ PD9530/PBT9500/PM9500Code 39 Set Length 2This feature specifies one of the bar code lengths for Code 39 Lengt

Strany 23 - 13

Enter/Exit Programming ModeProduct Reference Guide 109TRIOPTIC CODEThe following options apply to the Trioptic symbology.Tr

Strany 24 - Interface Selection

Introduction2PowerScan™ PD9530/PBT9500/PM9500Manual ConventionsThe following conventions are used in this document:The symbols listed below are used i

Strany 25 - Table 2. Available Interfaces

Enter/Exit Programming Mode110PowerScan™ PD9530/PBT9500/PM9500Code 32 Check Character TransmissionEnable this option to transmit the check character a

Strany 26 - KEYBOARD

Enter/Exit Programming ModeProduct Reference Guide 111CODE 39 CIP (FRENCH PHARMACEUTICAL)The following options apply to the

Strany 27 - Self Test and Statistics

Enter/Exit Programming Mode112PowerScan™ PD9530/PBT9500/PM9500CODE 39 LAPOSTEThe following options apply to the Code 39 LaPoste symbology.Code 39 LaPo

Strany 28 - Set Date and Time

Enter/Exit Programming ModeProduct Reference Guide 113CODE 128The following options apply to the Code 128 symbology.Code 12

Strany 29 - Linking the Reader

Enter/Exit Programming Mode114PowerScan™ PD9530/PBT9500/PM9500Code 128 Check Character TransmissionEnable this option to transmit the check character

Strany 30

Enter/Exit Programming ModeProduct Reference Guide 115Code 128 Sub-Code Exchange Transmission Enables/disables the transmis

Strany 31 - Configuration Using Bar Codes

Enter/Exit Programming Mode116PowerScan™ PD9530/PBT9500/PM9500Code 128 Length ControlThis feature specifies either variable length decoding or fixed l

Strany 32 - To program features:

Enter/Exit Programming ModeProduct Reference Guide 117Code 128 Set Length 1Specifies one of the bar code lengths for Code 1

Strany 33 - GLOBAL INTERFACE FEATURES

Enter/Exit Programming Mode118PowerScan™ PD9530/PBT9500/PM9500Code 128 Set Length 2This feature specifies one of the bar code lengths for Code 128 Len

Strany 34

Enter/Exit Programming ModeProduct Reference Guide 119GS1-128The following options apply to the GS1-128 symbology. (Also kn

Strany 35 - RS-232 ONLY INTERFACE

About the ReaderProduct Reference Guide 3About the ReaderThe PowerScan 2D is a family of feature-rich and rugged area image

Strany 36 - Baud Rate

Enter/Exit Programming Mode120PowerScan™ PD9530/PBT9500/PM9500CODE ISBT 128The following options apply to the ISBT 128 symbology.ISBT 128 Concatenatio

Strany 37 - Stop Bits

Enter/Exit Programming ModeProduct Reference Guide 121ISBT 128 Concatenation ModeSpecifies the concatenation mode between S

Strany 38

Enter/Exit Programming Mode122PowerScan™ PD9530/PBT9500/PM9500ISBT 128 Dynamic Concatenation TimeoutSpecifies the timeout used by the ISBT 128 Dynamic

Strany 39 - Handshaking Control

Enter/Exit Programming ModeProduct Reference Guide 123INTERLEAVED 2 OF 5 (I 2 OF 5)The following options apply to the I 2 o

Strany 40 - RS-232/USB-COM INTERFACES

Enter/Exit Programming Mode124PowerScan™ PD9530/PBT9500/PM9500I 2 of 5 Check Character CalculationThis option enables/disables calculation and verific

Strany 41 - Beep On ASCII BEL

Enter/Exit Programming ModeProduct Reference Guide 125I 2 of 5 Check Character TransmissionEnable this option to transmit t

Strany 42 - Beep On Not on File

Enter/Exit Programming Mode126PowerScan™ PD9530/PBT9500/PM9500I 2 of 5 Set Length 1This feature specifies one of the bar code lengths for I 2 of 5 Len

Strany 43

Enter/Exit Programming ModeProduct Reference Guide 127I 2 of 5 Set Length 2This feature specifies one of the bar code lengt

Strany 44

Enter/Exit Programming Mode128PowerScan™ PD9530/PBT9500/PM9500INTERLEAVED 2 OF 5 CIP HRThe following options apply to the Interleaved 2 of 5 CIP HR sy

Strany 45 - Indicate Transmission Failure

Enter/Exit Programming ModeProduct Reference Guide 129STANDARD 2 OF 5The following options apply to the Standard 2 of 5 sym

Strany 46

Introduction4PowerScan™ PD9530/PBT9500/PM9500The BC9xx0™ Base Station/ChargerThe BC9xx0 base station, when paired with one or more PowerScan™ 9500 rea

Strany 47 - KEYBOARD EMULATION SETTINGS

Enter/Exit Programming Mode130PowerScan™ PD9530/PBT9500/PM9500Standard 2 of 5 Check Character TransmissionThis feature enables/disables transmission o

Strany 48 - Country Mode

Enter/Exit Programming ModeProduct Reference Guide 131Standard 2 of 5 Set Length 1This feature specifies one of the bar cod

Strany 49 - Country Mode (continued)

Enter/Exit Programming Mode132PowerScan™ PD9530/PBT9500/PM9500Standard 2 of 5 Set Length 2This feature specifies one of the bar code lengths for Stand

Strany 50

Enter/Exit Programming ModeProduct Reference Guide 133INDUSTRIAL 2 OF 5The following options apply to the Industrial 2 of 5

Strany 51 - Send Control Characters

Enter/Exit Programming Mode134PowerScan™ PD9530/PBT9500/PM9500Industrial 2 of 5 Check Character TransmissionEnables/disables transmission of an Indust

Strany 52 - Wedge Quiet Interval

Enter/Exit Programming ModeProduct Reference Guide 135Industrial 2 of 5 Set Length 1This feature specifies one of the bar c

Strany 53 - Caps Lock State

Enter/Exit Programming Mode136PowerScan™ PD9530/PBT9500/PM9500Industrial 2 of 5 Set Length 2This feature specifies one of the bar code lengths for Ind

Strany 54 - USB Keyboard Speed

Enter/Exit Programming ModeProduct Reference Guide 137CODE IATAThe following options apply to the IATA symbology.IATA Enabl

Strany 55 - USB Keyboard Numeric Keypad

Enter/Exit Programming Mode138PowerScan™ PD9530/PBT9500/PM9500CODABARThe following options apply to the Codabar symbology.Codabar Enable/DisableWhen d

Strany 56

Enter/Exit Programming ModeProduct Reference Guide 139Codabar Check Character TransmissionEnable this option to transmit th

Strany 57 - USB-OEM INTERFACE

Battery SafetyProduct Reference Guide 5Battery SafetyTo reinstall, charge and/or perform any other action on the battery, f

Strany 58 - Interface Options

Enter/Exit Programming Mode140PowerScan™ PD9530/PBT9500/PM9500Codabar Start/Stop Character SetThis option specifies the format of transmitted Codabar

Strany 59 - DATA FORMAT

Enter/Exit Programming ModeProduct Reference Guide 141Codabar Quiet ZonesSpecifies the number of quiet zones for Codabar la

Strany 60

Enter/Exit Programming Mode142PowerScan™ PD9530/PBT9500/PM9500Codabar Set Length 1This feature specifies one of the bar code lengths for Codabar Lengt

Strany 61 - Global AIM ID

Enter/Exit Programming ModeProduct Reference Guide 143Codabar Set Length 2This feature specifies one of the bar code length

Strany 62 - AIM IDs (continued)

Enter/Exit Programming Mode144PowerScan™ PD9530/PBT9500/PM9500ABC CODABARThe following options apply to the ABC Codabar symbology.ABC Codabar Enable/D

Strany 63 - 53

Enter/Exit Programming ModeProduct Reference Guide 145ABC Codabar Dynamic Concatenation TimeoutSpecifies the timeout in 10-

Strany 64

Enter/Exit Programming Mode146PowerScan™ PD9530/PBT9500/PM9500ABC Codabar Force ConcatenationForces labels starting or ending with D to be concatenate

Strany 65

Enter/Exit Programming ModeProduct Reference Guide 147CODE 11The following options apply to the Code 11 symbology.Code 11 E

Strany 66 - Individually Set Label ID

Enter/Exit Programming Mode148PowerScan™ PD9530/PBT9500/PM9500Code 11 Check Character TransmissionThis feature enables/disables transmission of an opt

Strany 67 - − 1D Symbologies

Enter/Exit Programming ModeProduct Reference Guide 149Code 11 Set Length 1This feature specifies one of the bar code length

Strany 68

Introduction6PowerScan™ PD9530/PBT9500/PM9500charge / charge cycles before needing replacement. This number is higher if partial discharging / recharg

Strany 69 - 59

Enter/Exit Programming Mode150PowerScan™ PD9530/PBT9500/PM9500Code 11 Set Length 2This feature specifies one of the bar code lengths for Code 11 Lengt

Strany 70 - − 2D Symbologies

Enter/Exit Programming ModeProduct Reference Guide 151GS1 DATABAR™ OMNIDIRECTIONALThe following options apply to the GS1 Da

Strany 71 - Case Conversion

Enter/Exit Programming Mode152PowerScan™ PD9530/PBT9500/PM9500GS1 DataBar™ Omnidirectional 2D ComponentThis feature enables/disables a requirement tha

Strany 72

Enter/Exit Programming ModeProduct Reference Guide 153GS1 DataBar™ Expanded GS1-128 EmulationWhen enabled, GS1 DataBar™ Exp

Strany 73 - READING PARAMETERS

Enter/Exit Programming Mode154PowerScan™ PD9530/PBT9500/PM9500GS1 DataBar™ Expanded Length ControlThis feature specifies either variable length decodi

Strany 74 - Double Read Timeout

Enter/Exit Programming ModeProduct Reference Guide 155GS1 DataBar™ Expanded Set Length 1This feature specifies one of the b

Strany 75 - 65

Enter/Exit Programming Mode156PowerScan™ PD9530/PBT9500/PM9500GS1 DataBar™ Expanded Set Length 2This feature specifies one of the bar code lengths for

Strany 76 - LED AND BEEPER INDICATORS

Enter/Exit Programming ModeProduct Reference Guide 157GS1 DATABAR™ LIMITEDThe following options apply to the GS1 DataBar™ L

Strany 77 - Good Read Beep Frequency

Enter/Exit Programming Mode158PowerScan™ PD9530/PBT9500/PM9500GS1 DataBar™ Limited 2D ComponentThis feature enables/disables a requirement that a 2D l

Strany 78 - Good Read Beep Length

Enter/Exit Programming ModeProduct Reference Guide 159Code 93 Check Character CalculationEnables/disables calculation and v

Strany 79 - Good Read Beep Volume

Product Reference Guide 7Chapter 2SetupUnpackingCheck carefully to ensure the reader and any accessories ordered are pres-e

Strany 80 - Good Read LED Duration

Enter/Exit Programming Mode160PowerScan™ PD9530/PBT9500/PM9500Code 93 Length ControlThis feature specifies either variable length decoding or fixed le

Strany 81 - SCANNING FEATURES

Enter/Exit Programming ModeProduct Reference Guide 161Code 93 Set Length 1Specifies one of the bar code lengths for Code 93

Strany 82 - Pick Mode

Enter/Exit Programming Mode162PowerScan™ PD9530/PBT9500/PM9500Code 93 Set Length 2This feature specifies one of the bar code lengths for Code 93 Lengt

Strany 83 - Stand Mode Sensitivity

Enter/Exit Programming ModeProduct Reference Guide 163Code 93 Quiet ZonesEnables/disables quiet zones for Code 93.$CC9LO02(

Strany 84 - Stand Illumination Control

Enter/Exit Programming Mode164PowerScan™ PD9530/PBT9500/PM9500MSI Check Character CalculationEnables/Disables calculation and verification of an optio

Strany 85

Enter/Exit Programming ModeProduct Reference Guide 165MSI Length ControlThis feature specifies either variable length decod

Strany 86 - Aiming Duration Timer

Enter/Exit Programming Mode166PowerScan™ PD9530/PBT9500/PM9500MSI Set Length 1This feature specifies one of the bar code lengths for MSI Length Contro

Strany 87 - Partial Label Reading Control

Enter/Exit Programming ModeProduct Reference Guide 167MSI Set Length 2This feature specifies one of the bar code lengths fo

Strany 88 - Image Capture

Enter/Exit Programming Mode168PowerScan™ PD9530/PBT9500/PM9500PLESSEYThe following options apply to the Plessey symbology.Plessey Enable/DisableEnable

Strany 89 - MULTIPLE LABEL READING

Enter/Exit Programming ModeProduct Reference Guide 169Plessey Check Character TransmissionEnables/disables transmission of

Strany 90

Setup8PowerScan™ PD9530/PBT9500/PM9500Connecting the Cable (Corded versions)ABCDA. Rubber gasketB. Cable HolderC. CoverD. Connector Holder1. Slip the

Strany 91 - 1D SYMBOLOGIES

Enter/Exit Programming Mode170PowerScan™ PD9530/PBT9500/PM9500Plessey Set Length 1This feature specifies one of the bar code lengths for Plessey Lengt

Strany 92 - DISABLE ALL SYMBOLOGIES

Enter/Exit Programming ModeProduct Reference Guide 171Plessey Set Length 2This feature specifies one of the bar code length

Strany 93 - CODE EAN/UPC

172PowerScan™ PD9530/PBT9500/PM9500NOTES

Strany 94 - UPC-A Enable/Disable

Product Reference Guide 1732D SYMBOLOGIES 2D Global Features2D Maximum Decoding Time on page 1742D Normal/Inverse Symbol Co

Strany 95 - Expand UPC-A to EAN-13

Enter/Exit Programming Mode 2D Global Features174PowerScan™ PD9530/PBT9500/PM95002D Maximum Decoding TimeThis feature specifies the maximum amount of

Strany 96 - UPC-E Enable/Disable

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 1752D Structured AppendEnables/disables ability of re

Strany 97 - UPC-E 2D Component

Enter/Exit Programming Mode 2D Global Features176PowerScan™ PD9530/PBT9500/PM9500AZTEC CODEAztec Code Enable / Disable Enables/disables the ability of

Strany 98 - Expand UPC-E to UPC-A

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 177Aztec Code Set Length 1Specifies one of the bar co

Strany 99 - GTIN FORMATTING

Enter/Exit Programming Mode 2D Global Features178PowerScan™ PD9530/PBT9500/PM9500Aztec Code Set Length 2This feature specifies one of the bar code len

Strany 100 - EAN 13 (JAN 13)

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 179CHINA SENSIBLE CODEChina Sensible Code Enable / Di

Strany 101 - EAN-13 ISBN Conversion

Configuring the Base StationProduct Reference Guide 9Configuring the Base StationTo set up your BC9xx0 cradle you must:1. P

Strany 102 - ISSN Enable/Disable

Enter/Exit Programming Mode 2D Global Features180PowerScan™ PD9530/PBT9500/PM9500China Sensible Code Set Length 1Specifies one of the bar code lengths

Strany 103 - EAN 8 (JAN 8)

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 181China Sensible Code Set Length 2This feature speci

Strany 104 - Expand EAN 8 to EAN 13

Enter/Exit Programming Mode 2D Global Features182PowerScan™ PD9530/PBT9500/PM9500DATA MATRIXData Matrix Enable / Disable Enables/disables ability of r

Strany 105 - UPC/EAN GLOBAL SETTINGS

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 183Data Matrix DPM Decoding SafetyThis feature define

Strany 106 - UPC/EAN Quiet Zones

Enter/Exit Programming Mode 2D Global Features184PowerScan™ PD9530/PBT9500/PM9500Data Matrix Length ControlThis feature specifies either variable leng

Strany 107 - Optional Add-ons

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 185Data Matrix Set Length 2This feature specifies one

Strany 108 - Optional Add-On Timer

Enter/Exit Programming Mode 2D Global Features186PowerScan™ PD9530/PBT9500/PM9500MAXICODEMaxicode Enable / Disable Enables/disables ability of reader

Strany 109 - 99

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 187Maxicode Length ControlThis feature specifies eith

Strany 110 - Optional GS1-128 Add-On Timer

Enter/Exit Programming Mode 2D Global Features188PowerScan™ PD9530/PBT9500/PM9500Maxicode Set Length 2This feature specifies one of the bar code lengt

Strany 111 - 101

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 189PDF417PDF417 Enable / Disable Enables/disables the

Strany 112

Datalogic ADC, Inc.959 Terry Street | Eugene | OR 97402 | USATelephone: (1) 541-683-5700 | Fax: (1) 541-345-7140©2013-2014 Datalogic, Inc.An Unpublish

Strany 113 - Code 39 Enable/Disable

Setup10PowerScan™ PD9530/PBT9500/PM9500To change the Bracket:1. Remove the screw holding the Bracket in place. Retain the screw for re-use. 2. Careful

Strany 114

Enter/Exit Programming Mode 2D Global Features190PowerScan™ PD9530/PBT9500/PM9500PDF417 Set Length 1Specifies one of the bar code lengths for PDF417 L

Strany 115 - Code 39 Full ASCII

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 191PDF417 Set Length 2This feature specifies one of t

Strany 116 - Code 39 Length Control

Enter/Exit Programming Mode 2D Global Features192PowerScan™ PD9530/PBT9500/PM9500MICRO PDF417Micro PDF417 Enable / Disable Enables/disables the abilit

Strany 117 - Code 39 Set Length 1

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 193Micro PDF417 Length ControlThis feature specifies

Strany 118 - Code 39 Set Length 2

Enter/Exit Programming Mode 2D Global Features194PowerScan™ PD9530/PBT9500/PM9500Micro PDF417 Set Length 2This feature specifies one of the bar code l

Strany 119 - TRIOPTIC CODE

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 195QR CODEQR Code Enable / Disable Enables/disables t

Strany 120

Enter/Exit Programming Mode 2D Global Features196PowerScan™ PD9530/PBT9500/PM9500QR Code Set Length 1Specifies one of the bar code lengths for QR Code

Strany 121 - CODE 39 DANISH PPT

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 197QR Code Set Length 2This feature specifies one of

Strany 122 - CODE 39 PZN

Enter/Exit Programming Mode 2D Global Features198PowerScan™ PD9530/PBT9500/PM9500Micro QR Code Length ControlThis feature specifies either variable le

Strany 123 - CODE 128

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 199Micro QR Code Set Length 2This feature specifies o

Strany 124

Mounting the BC9xx0 CradleProduct Reference Guide 11Mounting for Portable UseIf portability of the cradle is required, the

Strany 125 - Code 128 Quiet Zones

Enter/Exit Programming Mode 2D Global Features200PowerScan™ PD9530/PBT9500/PM9500UCC COMPOSITEUCC Composite Enable / Disable Enables/disables the abil

Strany 126 - Code 128 Length Control

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 201UCC Optional Composite Timer Specifies the amount

Strany 127 - Code 128 Set Length 1

Enter/Exit Programming Mode 2D Global Features202PowerScan™ PD9530/PBT9500/PM9500POSTAL CODE SELECTIONEnables/disables the ability of the scanner to d

Strany 128 - Code 128 Set Length 2

2D Global Features Enter/Exit Programming ModeProduct Reference Guide 203Postal Code Selection (continued)$CPOEN06(CR)Posta

Strany 129 - GS1-128 2D Component

204PowerScan™ PD9530/PBT9500/PM9500NOTES

Strany 130 - CODE ISBT 128

Product Reference Guide 205 MOTION FEATURESMOTION AIMING CONTROL on page 205MOTION SENSITIVITY on page 206MOTIONLESS TIMEOU

Strany 131 - ISBT 128 Concatenation Mode

Enter/Exit Programming Mode206PowerScan™ PD9530/PBT9500/PM9500Motion SensitivityDefines discrete set of levels for scanner motion sensitivity when in

Strany 132

Product Reference Guide 207WIRELESS FEATURESThis section provides options and programming related to the reader’s wire-less

Strany 133 - INTERLEAVED 2 OF 5 (I 2 OF 5)

Enter/Exit Programming Mode208PowerScan™ PD9530/PBT9500/PM9500PBT9500-Only FeaturesBLUETOOTH SECURITY FEATURES starting on page 225•Bluetooth Security

Strany 134

Enter/Exit Programming ModeProduct Reference Guide 209Display and Keyboard Features•Display Operating Mode on page 247•Disp

Strany 135 - I 2 of 5 Length Control

Setup12PowerScan™ PD9530/PBT9500/PM9500Attaching the Metal Plate to BaseAlternatively, the mount can be attached first to the base, then both can be m

Strany 136 - I 2 of 5 Set Length 1

Enter/Exit Programming Mode210PowerScan™ PD9530/PBT9500/PM9500WIRELESS BEEPER FEATURESSeveral options are available to configure beeper behavior for R

Strany 137 - I 2 of 5 Set Length 2

Enter/Exit Programming ModeProduct Reference Guide 211Beep DurationThis feature controls the duration of radio-specific bee

Strany 138 - FOLLETT 2 OF 5

Enter/Exit Programming Mode212PowerScan™ PD9530/PBT9500/PM9500Beep VolumeSelects the beeper volume (loudness) of radio-specific beep indications. Ther

Strany 139 - STANDARD 2 OF 5

Enter/Exit Programming ModeProduct Reference Guide 213Docking BeepEnables/disables a beep indication when the handheld is p

Strany 140 - Fixed Length:

Enter/Exit Programming Mode214PowerScan™ PD9530/PBT9500/PM9500Leash Alarm (continued)$CBTLB03(CR)Leash Alarm = 3 Seconds$CBTLB04(CR)Leash Alarm = 4 Se

Strany 141 - Standard 2 of 5 Set Length 1

Enter/Exit Programming ModeProduct Reference Guide 215CONFIGURATION UPDATESSee page 304 in “References” for detailed inform

Strany 142 - Standard 2 of 5 Set Length 2

Enter/Exit Programming Mode216PowerScan™ PD9530/PBT9500/PM9500BATCH FEATURESBatch ModeThis option specifies whether to store labels in the handheld wh

Strany 143 - INDUSTRIAL 2 OF 5

Enter/Exit Programming ModeProduct Reference Guide 217Erase Batch MemoryWhen the scanner is configured in Manual Batch Mode

Strany 144

Enter/Exit Programming Mode218PowerScan™ PD9530/PBT9500/PM9500DIRECT RADIO AUTOLINK This feature enables/disables the ability to link a wireless handh

Strany 145 - 135

Enter/Exit Programming ModeProduct Reference Guide 219Source Radio Address Delimiter CharacterThis option specifies the del

Strany 146

Mounting the BC9xx0 CradleProduct Reference Guide 13Connecting and Disconnecting the Interface CableThe BC9xx0 can be conne

Strany 147 - CODE IATA

Enter/Exit Programming Mode220PowerScan™ PD9530/PBT9500/PM9500REAL TIME CLOCK (RTC) CONFIGURATIONCurrent DateSets the date of the internal Real Time C

Strany 148 - Codabar Enable/Disable

Enter/Exit Programming ModeProduct Reference Guide 221Date Tx FormatSets the format of the date.DEFAULT$CDTXF00\rYYYY-MM-DD

Strany 149 - 139

Enter/Exit Programming Mode222PowerScan™ PD9530/PBT9500/PM9500Date-Time SeparatorSets the character used to separate Date and Time from the next field

Strany 150

Enter/Exit Programming ModeProduct Reference Guide 223Date-Time Transmission OrderAllows the selection of the order of date

Strany 151 - Codabar Length Control

Enter/Exit Programming Mode224PowerScan™ PD9530/PBT9500/PM9500Power OffSee “Power Off” on page 20 for information about this feature.Powerdown Timeout

Strany 152 - Codabar Set Length 1

Enter/Exit Programming ModeProduct Reference Guide 225PBT9500-ONLY FEATURESThe features in this section are valid only for

Strany 153 - Codabar Set Length 2

Enter/Exit Programming Mode226PowerScan™ PD9530/PBT9500/PM9500Bluetooth Security ModeThis feature enables/disables authentication and encryption of th

Strany 154 - ABC CODABAR

Enter/Exit Programming ModeProduct Reference Guide 227Set PIN CodeDetermine the desired characters for the PIN code, then c

Strany 155 - 145

Enter/Exit Programming Mode228PowerScan™ PD9530/PBT9500/PM9500OTHER BLUETOOTH FEATURESReconnect Attempt IntervalThis feature specifies the interval ti

Strany 156

Enter/Exit Programming ModeProduct Reference Guide 229Bluetooth HID Variable PIN CodeSpecifies the selection available for

Strany 157 - Code 11 Enable/Disable

Setup14PowerScan™ PD9530/PBT9500/PM9500BC9xx0 ConfigurationThe BC9xx0 configuration can be performed in three ways: by using the Datalogic Aladdin™ so

Strany 158 - Code 11 Length Control

Enter/Exit Programming Mode230PowerScan™ PD9530/PBT9500/PM9500Bluetooth HID Alt ModeEnable/Disable the ability to correctly transmit a label to the ho

Strany 159 - Code 11 Set Length 1

Enter/Exit Programming ModeProduct Reference Guide 231Bluetooth Max Client Set the number of Readers that can connect to th

Strany 160 - Code 11 Set Length 2

Enter/Exit Programming Mode232PowerScan™ PD9530/PBT9500/PM9500Bluetooth Friendly Name You can set a meaningful name for PowerScan BT9500 that will app

Strany 161 - GS1 DATABAR™ OMNIDIRECTIONAL

Enter/Exit Programming ModeProduct Reference Guide 233Power ClassDEFAULT$CBTPP00(CR)

Strany 162 - GS1 DATABAR™ EXPANDED

Enter/Exit Programming Mode234PowerScan™ PD9530/PBT9500/PM9500HID Country Mode (continued)

Strany 163 - 153

Enter/Exit Programming ModeProduct Reference Guide 235HID Country Mode (continued)Country Mode = Norway

Strany 164

Enter/Exit Programming Mode236PowerScan™ PD9530/PBT9500/PM9500PM9500-ONLY FEATURESThe features in this section are valid only for the PowerScan PM9500

Strany 165 - 155

Enter/Exit Programming ModeProduct Reference Guide 237STAR Radio Transmit ModeSpecifies the transmission protocol for Star

Strany 166

Enter/Exit Programming Mode238PowerScan™ PD9530/PBT9500/PM9500Changing System Speed 1. Link the PM9500 with a BC9xxx Base. 2. With the PM9500, read a

Strany 167 - GS1 DATABAR™ LIMITED

it is possible to select a fixed channel with a frequency different from the default; please contact Datalogic Technical Support for information about

Strany 168 - Code 93 Enable/Disable

Interface SelectionProduct Reference Guide 15Table 2. Available InterfacesRS-232FEATURESRS-232 standard interface

Strany 169 - 159

Enter/Exit Programming Mode240PowerScan™ PD9530/PBT9500/PM9500COMPATIBILITY WITH PM8500Compatibility ModePowerscan PM9500 offers a limited set of feat

Strany 170 - Code 93 Length Control

Enter/Exit Programming ModeProduct Reference Guide 241BC9xxx BaseThe BC9xxx can be changed from Normal to Compatible mode u

Strany 171 - Code 93 Set Length 1

Enter/Exit Programming Mode242PowerScan™ PD9530/PBT9500/PM9500Base Address StampingEnables/disables the ability of base address information to be tran

Strany 172 - Code 93 Set Length 2

Enter/Exit Programming ModeProduct Reference Guide 243RS-485 Master Header/Terminator ( Prefix/Suffix) Specifies the Master

Strany 173 - MSI Enable/Disable

Enter/Exit Programming Mode244PowerScan™ PD9530/PBT9500/PM9500RS-485 Slave Minimum AddressSpecifies the minimum address that can be set for a Cradle i

Strany 174

Enter/Exit Programming ModeProduct Reference Guide 245RS-485 Network Working ModeSpecifies the selection available for Crad

Strany 175 - MSI Length Control

Enter/Exit Programming Mode246PowerScan™ PD9530/PBT9500/PM9500RS-485 Transmission Warning MessageEnable/Disable the ability of the cradle to transmit

Strany 176 - MSI Set Length 1

Enter/Exit Programming ModeProduct Reference Guide 247DISPLAY AND KEYBOARD FEATURESTwo keyboard models are available, the 4

Strany 177 - MSI Set Length 2

Enter/Exit Programming Mode248PowerScan™ PD9530/PBT9500/PM9500Display Off TimeoutSets the timeout for display, backlight and keyboard. Display Off Tim

Strany 178 - Plessey Enable/Disable

Enter/Exit Programming ModeProduct Reference Guide 249Display ContrastAdjust the contrast of the display. $CDICT

Strany 179 - Plessey Length Control

KEYBOARDFEATURESUSB Keyboard with alternate key encoding

Strany 180 - Plessey Set Length 1

Enter/Exit Programming Mode250PowerScan™ PD9530/PBT9500/PM9500Enable/disable buttonsThis feature offers the ability to enable or disable the keypad.Fi

Strany 181 - Plessey Set Length 2

Enter/Exit Programming ModeProduct Reference Guide 251Arrow Keys Mode (4-key models only)Configure the Arrow Keys functiona

Strany 182

Enter/Exit Programming Mode252PowerScan™ PD9530/PBT9500/PM9500Arrow Down String (4-key models only)Associate a pre-defined string to the Arrow Down ke

Strany 183 - 2D SYMBOLOGIES

Enter/Exit Programming ModeProduct Reference Guide 253CONFIGURE ACTIONS FOR FUNCTION KEYSEach of the function keys can be p

Strany 184 - 2D Maximum Decoding Time

Enter/Exit Programming Mode254PowerScan™ PD9530/PBT9500/PM9500ACTION CONFIGURATION FOR FUNCTION KEYS Configure actions (up to three) for the function

Strany 185 - 2D Structured Append

Enter/Exit Programming ModeProduct Reference Guide 255FUNCTION KEYS CONFIGURATION (16-KEY MODELS ONLY)Function Keys F3 thro

Strany 186 - AZTEC CODE

DEFAULT$CPWEQ0000\rShift No Actions Configured$CPWEQConfigure Actions for ShiftTo configure this feature, scan the ENTER/EXIT PRO-GRAMMING MODE bar co

Strany 187 - Aztec Code Set Length 1

Enter/Exit Programming ModeProduct Reference Guide 257Define Strings Configure string 1-5.To configure this feature, scan t

Strany 188 - Aztec Code Set Length 2

Enter/Exit Programming Mode258PowerScan™ PD9530/PBT9500/PM9500Set String IDSets the identifier of the predefined strings.$CPWEBSet String IDTo configu

Strany 189 - CHINA SENSIBLE CODE

Enter/Exit Programming ModeProduct Reference Guide 259Set String TerminatorSets the terminator of the predefined strings.$C

Strany 190

Customizing Configuration SettingsProduct Reference Guide 17Customizing Configuration SettingsConfigure Interface SettingsI

Strany 191 - 181

Enter/Exit Programming Mode260PowerScan™ PD9530/PBT9500/PM9500ADDITIONAL FEATURES FOR 16-KEY MODELSSee also "Function Keys Configuration (16-key

Strany 192 - DATA MATRIX

Enter/Exit Programming ModeProduct Reference Guide 261Mode SelectionThis feature allows the PowerScan 16K model to operate

Strany 193 - 183

Enter/Exit Programming Mode262PowerScan™ PD9530/PBT9500/PM9500Quantity/Code Send ModeThis feature defines the rules that will be used to send a QTY/CO

Strany 194 - Data Matrix Set Length 1

Enter/Exit Programming ModeProduct Reference Guide 263Interkey Timeout The 16-key keypad is organized like a cell phone, w

Strany 195 - Data Matrix Set Length 2

Enter/Exit Programming Mode264PowerScan™ PD9530/PBT9500/PM9500Append Code This function defines how a scanned barcode interacts with a pre-edited CODE

Strany 196 - MAXICODE

Enter/Exit Programming ModeProduct Reference Guide 265Echo This function enables/disables the keypad echo. It works only wh

Strany 197 - Maxicode Set Length 1

Enter/Exit Programming Mode266PowerScan™ PD9530/PBT9500/PM9500SHIFT Enable/Disable This function enables/disables the SHIFT function. $CPWER00\rDisab

Strany 198 - Maxicode Set Length 2

Enter/Exit Programming ModeProduct Reference Guide 267Lower Case This function enables/disables the capability to use the S

Strany 199 - PDF417 Length Control

Enter/Exit Programming Mode268PowerScan™ PD9530/PBT9500/PM9500Set F3 LabelThis item allows the user to change the default mnemonic label associated to

Strany 200 - PDF417 Set Length 1

Enter/Exit Programming ModeProduct Reference Guide 269Barcode/Key Different Data Format If this parameter is enabled, barc

Strany 201 - PDF417 Set Length 2

Setup18PowerScan™ PD9530/PBT9500/PM9500Resetting the Product Configuration to DefaultsRestore Custom DefaultsIf you aren’t sure what programming optio

Strany 202 - MICRO PDF417

Enter/Exit Programming Mode270PowerScan™ PD9530/PBT9500/PM9500Set Key Sequence ID Sets the identifier for keyboard composed strings. $CPWECSet keys se

Strany 203 - Micro PDF417 Set Length 1

Product Reference Guide 271Chapter 4ReferencesThis section contains explanations and examples of selected bar code fea-ture

Strany 204 - Micro PDF417 Set Length 2

References272PowerScan™ PD9530/PBT9500/PM9500RS-232 ParametersRS-232 OnlyBaud RateBaud rate is the number of bits of data transmitted per second. Set

Strany 205 - QR Code Length Control

RS-232 ParametersProduct Reference Guide 273RS-232/USB COM ParametersIntercharacter DelayThis parameter specifies the inter

Strany 206 - QR Code Set Length 1

References274PowerScan™ PD9530/PBT9500/PM9500ACK NAK OptionsThis enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. Wh

Strany 207 - MICRO QR CODE

RS-232 ParametersProduct Reference Guide 275NAK CharacterThis setting specifies an ASCII character or hex value to be used

Strany 208 - Micro QR Code Set Length 1

References276PowerScan™ PD9530/PBT9500/PM9500ACK NAK Timeout ValueThis option specifies the amount of time the reader waits for an ACK charac-ter from

Strany 209 - Micro QR Code Set Length 2

RS-232 ParametersProduct Reference Guide 277ACK NAK Retry CountThis feature specifies the number of times the reader retrie

Strany 210 - UCC COMPOSITE

References278PowerScan™ PD9530/PBT9500/PM9500Disable CharacterSpecifies the value of the RS-232 host command used to disable the reader.ASCII characte

Strany 211 - UCC Optional Composite Timer

RS-232 ParametersProduct Reference Guide 279Enable CharacterSpecifies the value of the RS-232 host command used to enable t

Strany 212 - POSTAL CODE SELECTION

Linking the ReaderProduct Reference Guide 19Linking the ReaderLink Datalogic RF Devices to BaseFor RF devices, before confi

Strany 213 - Postnet BB Control

References280PowerScan™ PD9530/PBT9500/PM9500Keyboard InterfaceWedge Quiet IntervalSpecifies the amount of time the reader looks for keyboard activity

Strany 214

Keyboard InterfaceProduct Reference Guide 281Intercharacter DelayThis parameter specifies the intercharacter delay between

Strany 215 - MOTION FEATURES

References282PowerScan™ PD9530/PBT9500/PM9500Intercode DelaySpecifies the delay between labels transmitted to the host for this interface. The selecta

Strany 216 - Motionless Timeout

SymbologiesProduct Reference Guide 283SymbologiesDatamatrix DPM Decoding SafetyDecoding Safety is used to configure a decod

Strany 217 - WIRELESS FEATURES

References284PowerScan™ PD9530/PBT9500/PM95005. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Prog Mode.Set Length 2This feature allows you to

Strany 218 - PM9500-Only Features

Data EditingProduct Reference Guide 285Data Editing When a bar code is scanned, additional information can be sent to the h

Strany 219 - Display and Keyboard Features

References286PowerScan™ PD9530/PBT9500/PM9500Global Prefix/SuffixUp to 20 ASCII characters may be added as a prefix (in a position before the bar code

Strany 220 - WIRELESS BEEPER FEATURES

Data EditingProduct Reference Guide 287• A modifier character (the modifier character is symbol dependent).SYMBOLOGY CHAR S

Strany 221 - Beep Duration

References288PowerScan™ PD9530/PBT9500/PM9500Label IDA Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01-0x

Strany 222 - Disconnect Beep

Data EditingProduct Reference Guide 289DATABAR EXPANDED COMPOSITERX 525800 d 525800DATABAR LIMITEDRL 524C00 v 760000DATABAR

Strany 223 - Leash Alarm

Product Reference GuideiTable of ContentsINTRODUCTION...

Strany 224 - Leash Alarm (continued)

Setup20PowerScan™ PD9530/PBT9500/PM9500Linking to a Bluetooth Adapter in HID mode1. Install any drivers provided with the Bluetooth adapter.2. Scan th

Strany 225 - CONFIGURATION UPDATES

References290PowerScan™ PD9530/PBT9500/PM9500POSTAL JAPANESE$R 245200 $R 245200POSTAL KIX$U 245500 $U 245500POSTAL PLANET$W 245700 $W 245700POSTAL POR

Strany 226 - BATCH FEATURES

Data EditingProduct Reference Guide 291Label ID: Set Individually Per SymbologyTo configure a Label ID individually for a s

Strany 227 - RF Batch Mode Transmit Delay

References292PowerScan™ PD9530/PBT9500/PM9500Table 39STEP ACTION EXAMPLES1.Scan the ENTER/EXIT bar code(Scanner enters Programming Mode)2.Determine pl

Strany 228 - RF ADDRESS STAMPING

Data EditingProduct Reference Guide 293Character ConversionCharacter conversion is an eight byte configuration item. The ei

Strany 229 - 219

References294PowerScan™ PD9530/PBT9500/PM9500Reading ParametersGood Read LED DurationThis feature specifies the amount of time that the Good Read LED

Strany 230 - Current Time

Scanning FeaturesProduct Reference Guide 295Scanning FeaturesScan ModeThis mode is associated with typical handheld reader

Strany 231 - Time Tx Format

References296PowerScan™ PD9530/PBT9500/PM9500Stand Mode Off TimeThis feature specifies the amount of time reader illumination stays off after pulling

Strany 232 - Date-Time Separator

Scanning FeaturesProduct Reference Guide 297Scanning Active TimeThis setting specifies the amount of time that the reader s

Strany 233 - Date-Time Transmission Order

References298PowerScan™ PD9530/PBT9500/PM9500Aiming Duration TimeSpecifies the frame of time the aiming pointer remains on after decoding a label, whe

Strany 234 - Powerdown Timeout

Scanning FeaturesProduct Reference Guide 299Flash On TimeThis feature specifies the ON time for the indicator LED while in

Strany 235 - PBT9500-ONLY FEATURES

Product Reference Guide 21Chapter 3Configuration Using Bar CodesThis and following sections provide programming bar codes t

Strany 236 - Select PIN Code Length

References300PowerScan™ PD9530/PBT9500/PM9500Flash Off TimeThis feature specifies the OFF time for the indicator LED while in Flash Mode. The selectab

Strany 237 - Set PIN Code

Scanning FeaturesProduct Reference Guide 301Multiple Labels Ordering by Code SymbologyThis feature Specifies the transmissi

Strany 238 - OTHER BLUETOOTH FEATURES

References302PowerScan™ PD9530/PBT9500/PM9500Table 47Hex ValueSymbology ID Hex ValueSymbology ID00Don't care2CGTIN501UPC-A2DGTIN802UPC-E2ES2OF503

Strany 239 - 229

Motion FeaturesProduct Reference Guide 303Motion FeaturesMotionless TimeoutThis setting specifies the amount of time that t

Strany 240 - Bluetooth HID Alt Mode

References304PowerScan™ PD9530/PBT9500/PM9500Wireless FeaturesAutomatic Configuration UpdateWhen this feature is enabled, the base station and reader

Strany 241 - Bluetooth Max Client

Wireless FeaturesProduct Reference Guide 305STAR Radio Protocol TimeoutThis parameter sets the valid wait time before trans

Strany 242 - Bluetooth Friendly Name

References306PowerScan™ PD9530/PBT9500/PM9500PM9500-Only FeaturesChanging System Speed in Normal Mode1. Link the PM9500 with a BC9xxx Base. 2. With th

Strany 243 - HID Country Mode

Wireless FeaturesProduct Reference Guide 3077. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-ming Mode.Chan

Strany 244 - HID Country Mode (continued)

References308PowerScan™ PD9530/PBT9500/PM9500NOTES

Strany 245

Product Reference Guide 309Chapter 5Message FormattingMessage Formatting is available for PM9500 models only. For this feat

Strany 246 - PM9500-ONLY FEATURES

Enter/Exit Programming Mode22PowerScan™ PD9530/PBT9500/PM9500• "2D Symbologies" on page 173 provides configuration of a personal-ized mix of

Strany 247 - STAR Radio Transmit Mode

Message Formatting310PowerScan™ PD9530/PBT9500/PM9500Cursor ControlESC [ n AUp n rows, no scrollESC [ n BDown n rows, no scrollESC [ n CRight n column

Strany 248 - Frequency Agility

Product Reference Guide 311LED and Beeper ControlESC [ 0 qEmit short High tone + short delayESC [ 1 qEmit short Low tone +

Strany 249 - Table 26. Frequency Agility

Message Formatting312PowerScan™ PD9530/PBT9500/PM9500NOTES

Strany 250 - COMPATIBILITY WITH PM8500

Product Reference Guide 313Appendix A Technical SpecificationsThe tables that follow contain Physical and Performance Chara

Strany 251 - Return to Normal

Performance CharacteristicsLight Source LEDRoll (Tilt) Tolerance ± 180° Pitch Tolerance ± 40° Skew (Yaw) Tolerance ± 40°Print Contrast Minimum15% min

Strany 252 - Base Address Stamping

Decode CapabilityItem Description1D Bar CodesGS1 Databar linear codes, UPC/EAN (A,E,13,8), UPC/EAN with P2/P5 Addons, UPC/EAN Coupons, ISBN, Code128,

Strany 253 - RS-485 Cradle Address

Item DescriptionRegulatoryPD9530 (Corded Models)PBT9500 PM9500Electrical SafetyUL 60950, CSA C22.2 No. 60950, IEC 60950UL 60950, CSA C22.2 No. 60950,

Strany 254 - RS-485 Slave Maximum Address

Imager LabelingProduct Reference Guide 317Imager LabelingSample labels are shown for illustrative purposes only. Please vie

Strany 255 - RS-485 Network Working Mode

Technical Specifications318PowerScan™ PD9530/PBT9500/PM9500Standard Cable Pinouts The data below provides standard pinout information for the interfac

Strany 256 - RS-485 Network Baud Rate

LED and Beeper IndicationsProduct Reference Guide 319LED and Beeper IndicationsThe reader’s beeper sounds and its LED illum

Strany 257 - DISPLAY AND KEYBOARD FEATURES

Enter/Exit Programming ModeProduct Reference Guide 23GLOBAL INTERFACE FEATURESThe following interface features are configur

Strany 258 - Backlight Enable

Technical Specifications320PowerScan™ PD9530/PBT9500/PM9500Error CodesUpon startup, if the reader sounds a long tone, this means the reader has not pa

Strany 259 - Font Size

Product Reference Guide 321Appendix BSample Bar CodesThe sample bar codes in this appendix are typical representations for

Strany 260 - Enable/disable buttons

Sample Bar Codes322PowerScan™ PD9530/PBT9500/PM9500Sample Bar Codes (continued) Code 32Codabar13579 Code 93 Code 11123456789

Strany 261 - String Association Mode:

Product Reference Guide 323GS1 DataBar™ (RSS)GS1 DataBar™ Expanded Stacked10293847560192837465019283746029478450366523GS1 D

Strany 262

Sample Bar Codes324PowerScan™ PD9530/PBT9500/PM95002D Bar CodesAztec DatamatrixChina Sensible Code MaxiCodeTest MessagePDF 417ABCabcMicro PDF 417

Strany 263 - 253

Product Reference Guide 325Appendix CStandard DefaultsThe most common configuration settings are listed in the “Default” co

Strany 264 - Configure Actions for F2

Standard Defaults326PowerScan™ PD9530/PBT9500/PM9500Indicate Transmission FailureEnable 35Disable Character‘D’ 36Enable Character‘E’ 36KEYBOARD WEDGEC

Strany 265 - 255

Standard DefaultsProduct Reference Guide 327Good Read LED Duration300 ms 70Scanning FeaturesScan ModeTrigger Single 71Stand

Strany 266

Standard Defaults328PowerScan™ PD9530/PBT9500/PM9500UPC-EUPC-E Enable/DisableEnable 86UPC-E Check Character TransmissionSend 87UPC-E 2D Component2D Co

Strany 267 - Define Strings

Standard DefaultsProduct Reference Guide 329Code 39 Check Character CalculationDon’t Calculate 103Code 39 Check Character T

Strany 268 - Set String Header

Enter/Exit Programming Mode24PowerScan™ PD9530/PBT9500/PM9500NOTES

Strany 269 - Set String Terminator

Standard Defaults330PowerScan™ PD9530/PBT9500/PM9500Code 128 Set Length 280 118GS1-128GS1-128 EnableTransmit in Code 128 Data Format119GS1-128 2D Comp

Strany 270 - Display Time Stamping Mode

Standard DefaultsProduct Reference Guide 331Industrial 2 of 5 Check Character TransmissionEnable 134Industrial 2 of 5 Lengt

Strany 271 - Quantity Field

Standard Defaults332PowerScan™ PD9530/PBT9500/PM9500GS1 DataBar™ OmnidirectionalGS1 DataBar™ Omnidirectional Enable/DisableDisable 151GS1 DataBar™ Omn

Strany 272 - Quantity/Code Separator

Standard DefaultsProduct Reference Guide 333MSI Set Length 11 166MSI Set Length 250 167PlesseyPlessey Enable/DisableDisable

Strany 273 - Interkey Timeout

Standard Defaults334PowerScan™ PD9530/PBT9500/PM9500PDF417 Enable / DisableEnable 189PDF417 Length ControlVariable 189PDF417 Set Length 11 190PDF417 S

Strany 274 - Append Code

Standard DefaultsProduct Reference Guide 335Leash AlarmDisable 213Automatic Configuration UpdateEnable 215Copy Configuratio

Strany 275 - Keypress Sound

Standard Defaults336PowerScan™ PD9530/PBT9500/PM9500Features for PM9500 Models OnlySTAR Radio Protocol Timeout02 236STAR Radio Transmit ModeAck from c

Strany 276 - SHIFT key association

Standard DefaultsProduct Reference Guide 337Configure Actions for Shift (16-key models only)No Actions Configured 256Defin

Strany 277 - Set F2 Label

Standard Defaults338PowerScan™ PD9530/PBT9500/PM9500Restore Factory ConfigurationIf you want to restore the Factory Configuration for your imager, sca

Strany 278 - Set F4 Label

Product Reference Guide 339Appendix DKeypadUse the bar codes in this appendix to enter numbers as you would select digits/c

Strany 279 - Set Barcode Terminator

Product Reference Guide 25RS-232 ONLY INTERFACEBAUD RATE on page 26DATA BITS on page 27STOP BITS on page 27PARITY on page 2

Strany 280 - Set Key Sequence Terminator

Keypad340PowerScan™ PD9530/PBT9500/PM9500Keypad (continued)ABCDEFMake a mistake? Scan the CANCEL bar code to abort and not save the entry string. You

Strany 281 - Chapter 4

Product Reference Guide 341Appendix EScancode TablesControl Character EmulationControl character emulation selects from dif

Strany 282 - Clear to Send

342PowerScan™ PD9530/PBT9500/PM9500Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLETable 57. Scancode Set When Control Character is 0

Strany 283 - RS-232/USB COM Parameters

Product Reference Guide 343Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE (continued)Table 58. Scancode Set When Control Character

Strany 284 - ACK Character

344PowerScan™ PD9530/PBT9500/PM9500Interface Type PC AT PS/2 Alt Mode or USB-Keyboard Alt ModeTable 59. Scancode Set When Control Character is 00 or 0

Strany 285 - NAK Character

Product Reference Guide 345Interface Type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode (continued)Table 60. Scancode Set When Control Character is 02

Strany 286 - ACK NAK Timeout Value

346PowerScan™ PD9530/PBT9500/PM9500Digital InterfaceTable 61. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC

Strany 287 - ACK NAK Retry Count

Product Reference Guide 347IBM31xx 102-keyTable 63. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF

Strany 288 - Disable Character

348PowerScan™ PD9530/PBT9500/PM9500IBM XTTable 65. Scancode Set When Control Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0

Strany 289 - Enable Character

Microsoft Windows Codepage 1252Product Reference Guide 349Microsoft Windows Codepage 1252Windows-1252 is a character encodi

Strany 290 - Keyboard Interface

Enter/Exit Programming Mode26PowerScan™ PD9530/PBT9500/PM9500Baud RateSee page 272 for information on this feature.$CR2BA00(CR)Baud Rate = 1200$CR2BA0

Strany 291 - Intercharacter Delay

Scancode Tables350PowerScan™ PD9530/PBT9500/PM9500NOTES

Strany 292 - Intercode Delay

ASCII ChartASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.HexNo.NULSOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSIDLEDC1DC2DC3DC4NAKSYNETBCANE

Strany 293 - Symbologies

Datalogic ADC, Inc.959 Terry Street | Eugene |OR 97402 | USATelephone: (1) 541-683-5700 | Fax: (1) 541-345-7140©2013-2014 Datalogic, Inc. All rights r

Strany 294 - Set Length 2

Enter/Exit Programming ModeProduct Reference Guide 27Data BitsThis parameter allows the reader to interface with devices re

Strany 295 - Data Editing

Enter/Exit Programming Mode28PowerScan™ PD9530/PBT9500/PM9500ParityThis feature specifies parity required for sending and receiving data. Select the p

Strany 296 - 00 - 20 Characters (ASCII)

Enter/Exit Programming ModeProduct Reference Guide 29Handshaking ControlDEFAULT$CR2HC00(CR)Handshaking Control = RTS$CR2HC0

Strany 297 - Figure 9. AIM ID

ContentsiiPowerScan™ PD9530/PBT9500/PM9500Beep On ASCII BEL ...

Strany 298 - Label ID

Product Reference Guide 30RS-232/USB-COM INTERFACESINTERCHARACTER DELAY on page 31BEEP ON ASCII BEL on page 31BEEP ON NOT O

Strany 299 - 289

Enter/Exit Programming ModeProduct Reference Guide 31Intercharacter DelayThis parameter specifies the intercharacter delay

Strany 300

Enter/Exit Programming Mode32PowerScan™ PD9530/PBT9500/PM9500Beep On Not on FileThis option enables/disables the action of the reader to sound a three

Strany 301 - 291

Enter/Exit Programming ModeProduct Reference Guide 33ACK CharacterThis setting specifies an ASCII character or hex value to

Strany 302 - . Label ID Examples

Enter/Exit Programming Mode34PowerScan™ PD9530/PBT9500/PM9500ACK NAK Timeout ValueThis option specifies the amount of time the reader waits for an ACK

Strany 303 - Character Conversion

Enter/Exit Programming ModeProduct Reference Guide 35ACK NAK Error HandlingThis feature specifies the method the reader use

Strany 304 - Reading Parameters

Enter/Exit Programming Mode36PowerScan™ PD9530/PBT9500/PM9500Disable CharacterSpecifies the value of the RS-232 host command used to disable the reade

Strany 305 - Scanning Features

Product Reference Guide 37KEYBOARD EMULATION SETTINGSCOUNTRY MODE on page 38SEND CONTROL CHARACTERS on page 41WEDGE QUIET I

Strany 306 - Stand Mode Off Time

Enter/Exit Programming Mode38PowerScan™ PD9530/PBT9500/PM9500Country ModeThis feature specifies the country/language supported by the keyboard. Severa

Strany 307 - Scanning Active Time

Enter/Exit Programming ModeProduct Reference Guide 39Country Mode (continued)Supports only the interfaces listed in the Cou

Strany 308 - Aiming Duration Time

ContentsProduct Reference GuideiiiDISABLE ALL SYMBOLOGIES ...

Strany 309 - Flash On Time

Enter/Exit Programming Mode40PowerScan™ PD9530/PBT9500/PM9500Country Mode (continued)$CKBCO12(CR)Country Mode = PolandSupports only the interfaces lis

Strany 310 - Flash Off Time

Enter/Exit Programming ModeProduct Reference Guide 41Send Control CharactersThis feature specifies how the reader transmits

Strany 311 - 301

Enter/Exit Programming Mode42PowerScan™ PD9530/PBT9500/PM9500Wedge Quiet IntervalSpecifies amount of time to look for keyboard activity before scanner

Strany 312 - . Symbology Hex Values

Enter/Exit Programming ModeProduct Reference Guide 43Caps Lock StateThis option specifies the format in which the reader se

Strany 313 - Motion Features

Enter/Exit Programming Mode44PowerScan™ PD9530/PBT9500/PM9500USB Keyboard SpeedThis option specifies the USB poll rate for a USB keyboard.DEFAULT$CKBS

Strany 314 - Wireless Features

$CKBSP07(CR)USB Keyboard Speed = 7ms$CKBSP08(CR)USB Keyboard Speed = 8ms$CKBSP09(CR)USB Keyboard Speed = 9ms$CKBSP0A(CR)USB Keyboard Speed = 10msEnter

Strany 315 - STAR Radio Protocol Timeout

Enter/Exit Programming Mode46PowerScan™ PD9530/PBT9500/PM9500NOTES

Strany 316 - Bluetooth-Only Features

Product Reference Guide 47USB-OEM INTERFACEUSB-OEM DEVICE USAGE on page 48INTERFACE OPTIONS on page 48Feature settings for

Strany 317 - 307

Enter/Exit Programming Mode48PowerScan™ PD9530/PBT9500/PM9500USB-OEM Device UsageThe USB-OEM protocol allows for the reader to be identified as one of

Strany 318

Product Reference Guide 49DATA FORMATGLOBAL PREFIX/SUFFIX (HEADER/TERMINA-TOR) on page 50GLOBAL AIM ID on page 51LABEL ID s

Strany 319 - Message Formatting

ContentsivPowerScan™ PD9530/PBT9500/PM9500Code 128 Sub-Code Exchange Transmission ...

Strany 320 - Clearing Display

Enter/Exit Programming Mode50PowerScan™ PD9530/PBT9500/PM9500Global Prefix/Suffix (Header/Terminator)This option sets up to 20 characters each from th

Strany 321 - Setting RTC

Enter/Exit Programming ModeProduct Reference Guide 51Global AIM IDThis feature enables/disables addition of AIM IDs for all

Strany 322

Enter/Exit Programming Mode52PowerScan™ PD9530/PBT9500/PM9500 AIM IDs (continued)CODE39 LAPOSTE X 58CODE39 PZN X 58CODE93 G 47DATABAR 14 e 65DATABAR 1

Strany 323 - Electrical Characteristics

Enter/Exit Programming ModeProduct Reference Guide 53 AIM IDs (continued)MAXICODE U 55MICRO QR Q 51MICRO PDF L 4CMSI M 4DPD

Strany 324 - Technical Specifications

Enter/Exit Programming Mode54PowerScan™ PD9530/PBT9500/PM9500Set AIM ID Individually for GS1-128This feature configures a Label ID individually for th

Strany 325 - 315

Enter/Exit Programming ModeProduct Reference Guide 55Label IDA Label ID is a customizable code of up to three ASCII charact

Strany 326 - Radio Features

Enter/Exit Programming Mode56PowerScan™ PD9530/PBT9500/PM9500Individually Set Label IDThis feature configures a Label ID individually for a single sym

Strany 327 - Imager Labeling

Enter/Exit Programming ModeProduct Reference Guide 57Label ID Symbology Selection − 1D Symbologies This option selects the

Strany 328 - Standard Cable Pinouts

Enter/Exit Programming Mode58PowerScan™ PD9530/PBT9500/PM9500Label ID Symbology Selection − 1D Symbologies (continued)$C8BIDSet EAN 8 Label ID Charact

Strany 329 - LED and Beeper Indications

Enter/Exit Programming ModeProduct Reference Guide 59Label ID Symbology Selection − 1D Symbologies (continued)$CPMIDSet IMB

Strany 330 - Error Codes

ContentsProduct Reference GuidevGS1 DataBar™ Omnidirectional GS1-128 Emulation ...

Strany 331 - Sample Bar Codes

Label ID Symbology Selection − 1D Symbologies (continued)$CPSIDSet Swedish Postal Code Label ID Character(s)$CA5IDSet UPC-A P5 Label ID Character(s)$C

Strany 332 - Sample Bar Codes (continued)

Label IDProduct Reference Guide 61Advanced Formatting: User Label EditAdvanced formatting is available to create user label

Strany 333 - GS1 DataBar™-14

62PowerScan™ PD9530/PBT9500/PM9500NOTES

Strany 334 -

Product Reference Guide 63 READING PARAMETERS DOUBLE READ TIMEOUT on page 64 SCANNING ACTIVE TIME on page 74LED AND BEEPER

Strany 335 - Standard Defaults

Enter/Exit Programming Mode64PowerScan™ PD9530/PBT9500/PM9500Double Read TimeoutDouble Read Timeout prevents a double read of the same label by settin

Strany 336

Enter/Exit Programming ModeProduct Reference Guide 65Double Read Timeout (continued)$CSNDR50(CR)Double Read Timeout = 0.8

Strany 337 - 327

Enter/Exit Programming Mode66PowerScan™ PD9530/PBT9500/PM9500LED AND BEEPER INDICATORSPower On AlertDisables or enables the indication (from the Beepe

Strany 338

Enter/Exit Programming ModeProduct Reference Guide 67Good Read Beep TypeSpecifies whether the good read beep has a mono or

Strany 339 - 329

Enter/Exit Programming Mode68PowerScan™ PD9530/PBT9500/PM9500Good Read Beep Length

Strany 340

Enter/Exit Programming ModeProduct Reference Guide 69Good Read Beep VolumeSelects the beeper volume (loudness) upon a good

Strany 341 - 331

ContentsviPowerScan™ PD9530/PBT9500/PM9500PDF417 Set Length 2 ...

Strany 342

Enter/Exit Programming Mode70PowerScan™ PD9530/PBT9500/PM9500Good Read LED DurationThis feature specifies the amount of time that the Good Read LED re

Strany 343 - 333

Enter/Exit Programming ModeProduct Reference Guide 71SCANNING FEATURESScan ModeSelects the reader’s scan operating mode. Se

Strany 344

Enter/Exit Programming Mode72PowerScan™ PD9530/PBT9500/PM9500Stand Mode IndicationThis operation is useful for indicating when the reader is in Stand

Strany 345 - 335

Enter/Exit Programming ModeProduct Reference Guide 73Stand Mode SensitivitySets the sensitivity level for stand mode wakeup

Strany 346

Enter/Exit Programming Mode74PowerScan™ PD9530/PBT9500/PM9500Scanning Active TimeThis setting specifies the amount of time that the reader stays in sc

Strany 347 - 337

Enter/Exit Programming ModeProduct Reference Guide 75Flash On TimeThis feature specifies the ON time for the indicator LED

Strany 348 - Restore Factory Configuration

Enter/Exit Programming Mode76PowerScan™ PD9530/PBT9500/PM9500Aiming PointerEnables/disables the aiming pointer for all symbologies.$CTAAP00(CR)Aiming

Strany 349 - Appendix D

Enter/Exit Programming ModeProduct Reference Guide 77Green Spot DurationSpecifies the duration of the good read pointer bea

Strany 350 - Keypad (continued)

Enter/Exit Programming Mode78PowerScan™ PD9530/PBT9500/PM9500Decode Negative ImageEnable/Disable the ability to decode a negative image for all symbol

Strany 351 - Scancode Tables

Enter/Exit Programming ModeProduct Reference Guide 79 MULTIPLE LABEL READINGIn standard (default) mode, when the reader’s a

Strany 352 - Alt Mode sequence

ContentsProduct Reference GuideviiBluetooth HID Send Unknown ASCII Char ...

Strany 353 - Product Reference Guide 343

Enter/Exit Programming Mode80PowerScan™ PD9530/PBT9500/PM9500Multiple Labels Ordering by Code SymbologyThis feature allows you to specify the order mu

Strany 354

Product Reference Guide 811D SYMBOLOGIESThe reader supports the following 1D symbologies (bar code types). See "2D Sym

Strany 355 - Product Reference Guide 345

Enter/Exit Programming Mode82PowerScan™ PD9530/PBT9500/PM9500DISABLE ALL SYMBOLOGIESUse this feature to disable all symbologies.1. Scan the ENTER/EXIT

Strany 356 - Digital Interface

Enter/Exit Programming ModeProduct Reference Guide 83CODE EAN/UPCCoupon ControlThis feature is used to control the reader’s

Strany 357 - IBM31xx 102-key

Enter/Exit Programming Mode84PowerScan™ PD9530/PBT9500/PM9500UPC-AThe following options apply to the UPC-A symbology.UPC-A Enable/DisableWhen disabled

Strany 358

Enter/Exit Programming ModeProduct Reference Guide 85Expand UPC-A to EAN-13Expands UPC-A data to the EAN-13 data format. Se

Strany 359 - 349

Enter/Exit Programming Mode86PowerScan™ PD9530/PBT9500/PM9500UPC-A 2D ComponentThis feature enables/disables a requirement that a 2D label component b

Strany 360

Enter/Exit Programming ModeProduct Reference Guide 87UPC-E Check Character TransmissionEnable this option to transmit the c

Strany 361 - ASCII Chart

Enter/Exit Programming Mode88PowerScan™ PD9530/PBT9500/PM9500Expand UPC-E to EAN-13Expands UPC-E data to the EAN-13 data format. Selecting this featur

Strany 362

Enter/Exit Programming ModeProduct Reference Guide 89UPC-E Number System Character TransmissionThis feature enables/disable