Setup Procedure Using Programming Barcodes
22
2.2 FOR MATRIX 410 OR MATRIX 210 FAMILY READERS
For Matrix 410 or Matrix 210 readers
5
having software 6.10 or later, connected to either a
QL500 or a BM2x0 module (inside a CBX connection box), you can setup the CBX Ethernet
communication with programming barcodes.
Ì$CBETHD$-}Î
CBX Ethernet TCP/IP enabled
DHCP enabled
Using the X-PRESS™ interface setup functions described in the Quick Reference Guide,
correctly position the reader and read one of these barcodes with the Learn function
.
The reader can now communicate using CBX Ethernet TCP/IP.
For reader configuration through VisiSet™ using Ethernet TCP/IP, follow one of the
procedures in par. 2.3.
Ì$CBETHN$-\Î
CBX Ethernet TCP/IP enabled
DHCP disabled
(uses static IP Address parameters) *
The Factory Default static IP address parameter settings for CBX Ethernet TCP/IP for all
Matrix 410 or Matrix 210 readers are:
IP Address = 172.24.24.1
Subnet Mask = 255.255.0.0
Gateway Address = 172.24.255.254
5
Except Matrix 210™ UHD models.