DS6000 Family
Software Configuration Parameter Guide
-
Code Definition
-
Operating Modes
-
Reading System Layout
-
Reading Parameters
-
Data Communication Settings
-
Digital I/O Setting
Cove
r
28/04/2004
Zobrazit stránku 0
1 2 3 4 5 6 ... 68 69

Shrnutí obsahu

Strany 1 - DS6000 Family

DS6000 Family Software Configuration Parameter Guide - Code Definition - Operating Modes - Reading System Layout

Strany 2

- 4 - Code label setting#1 = Code 93 Code label setting#2 = Interleaved 2/5 Code label setting#3= EAN-8 Code label setting#4= UPC-A Logical Co

Strany 3 - Test Operating Mode

Multiple Read Message This string will be sent if, during the reading phase, the scanner reads more than the number of the expected barcodesset by

Strany 4 - Automatic Operating Mode

Code Definition The parameters available in this group define the properties of the code symbology selected. The following table lists allparameters

Strany 5

- Code 128 - EAN/UPC - Code 93 For these symbologies the check digit control is not all

Strany 6 - Network Wizard

Code Label Local No Read String This is used when the defined code is not read in the reading phase. The Local No Read String is enabled when settingt

Strany 7

Min/Max Code Position These parameters specify where in the scan line a particular code can be found. The scan line is divided into 256physical po

Strany 8

Local No Read Strings This group allows defining a Local No Read string for each group used in the Logical Combination Rule. This group allows defin

Strany 9

Operating Modes The available operating modes are listed below: zOn Line zAutomatic zContinuous zTest zPackTrack™ Operating Modes

Strany 10 - Code Definition

On Line This group allows defining the following parameters: In this operating mode, the scanner is connected to an external presence sensor and a

Strany 11

Stop Input Number It defines the number of the input ending the reading phase. Stop Input Active Level Allows the selection of the active state of

Strany 12

Wizard for Quick Reader Setup After installing the Genius™ software program the following window appears asking the user to choose the desiredconfig

Strany 13 - Code Definition All Codes

Automatic The device does not require connections with external presence sensors in this operating mode. In this mode the scanner is continuously sc

Strany 14

Continuous The device does not require connections with external presence sensors in this operating mode. The reading phase is always active and, di

Strany 15

Test The Test Mode reports information about the reading performance of the laser beam and the code is continuously read. This operating mode allows

Strany 16 - Local No Read Strings

PackTrack™ This group allows defining the following parameters: PackTrack™ is a patented operating mode for Datalogic Omni-Directional

Strany 17 - Operating Modes

This coordinate system is absolute for the reading station, i.e. is valid for all the scanners independently from theirposition or orientation

Strany 18 - On Line

Encoder Step is 6.35 /2 = 3.175 mm (318) Conveyor Speed This parameter is available only when the Physical Encoder is disabled. It defines the

Strany 19

Minimum Pack Length It defines the minimum length of a pack (mm). Window Dimension The measurement of a barcode position in absolute coordinates p

Strany 20 - Automatic

Reading System Layout This group is available only when working in On-Line, PackTrack™ and Continuous operating modes. Available parameters are the

Strany 21 - Continuous

Reading Parameters This group allows defining the following parameters: Beam Shutter This parameter is active only when the Operating Mode is set

Strany 22 - Test Mode Send Data

Reconstruction Parameters This group allows defining the following parameters: Max Scan Gap This parameter sets the number of scans without a matc

Strany 23 - PackTrack™

Test Operating Mode This operating mode causes the reader to be continuously activated allowing to verify its reading features and itsreadin

Strany 24 - Encoder Step

Scan Line Amplitude This group allows setting the amplitude of scanner laser line in order to illuminate only the desired reading area.Available par

Strany 25

Flash Flash allows to configure the parameters relative the autofocus: Flash Mode This parameter defines the operating mode used by the scanne

Strany 26 - Window Dimension

Fixed This Flash Mode allows to position the scanner focus exactly on the object containing the barcode label: Fixed Distance This parameter fix

Strany 27 - Reading System Layout

Triggered This Flash Mode allows assigning the desired focus distance to one or more inputs. In this way, upon activation of eachinput the scanner f

Strany 28 - Reading Parameters

NOTE If Input 4 has been already associated to another function (i.e. Presence Sensor), an e

Strany 29 - Reconstruction Parameters

Continuous This Flash Mode allows the scanner focus to dynamically cover the defined reading range where objects containing barcodes are expected. A

Strany 30 - Scan Line Amplitude

DFlash This Flash Mode allows discretizing the total focus distance into eight different focus ranges in order to guarantee themaximum flexibility of

Strany 31 - Flash Mode

Offset Distance According to the relative positioning between scanner and target code, the minimum detected distance could not beequal to the barcode

Strany 32 - Fixed Flash Mode

Oscillating Mirror This group allows defining the oscillating amplitude of the Oscillating Mirror. Available parameters are the following: Osc

Strany 33 - Triggered

Data Communication Settings This group allows defining the following parameter: The communication may occur through: - Crisplant Para

Strany 34

On Line Operating Mode This operating mode causes the reader to be connected to an external Presence Sensor using EXT TRIG+ and EXTTRIG- inputs.

Strany 35

Crisplant Parameters This group allows defining all the parameters managing this communication protocol: Crisplant Manufacturer ID It defines

Strany 36 - DFlash Flash Mode

Data Format Data Format allows to configure the parameters relative to the message format and the transmission mode: Header Tx Start It select

Strany 37

Standard Parameters Available parameters for this group are the following: Header String Headers (up to 128 bytes) can be defined and transmitte

Strany 38 - Oscillating Mirror

Code Field Length Setting The code field length can be (in number of characters/digits) can be specified in order to be accepted for decoding:

Strany 39 - Data Communication Settings

Multidata When a Master MULTIDATA configuration is selected, this group allows the Slave address to be included before theSlave message together wit

Strany 40 - Crisplant Parameters

Main Serial Port This option determines the communication between the scanner and the Host, or, in a multi-sided layout, between several scanners an

Strany 41 - Data Format

Main Serial Port Parameters This group allows defining all parameters managing the serial communication: Main Port Communication Mode The foll

Strany 42 - Standard Parameters

Baud Rate Baud rate is the transmission speed in a communication line. Parity Parity is a parameter indicating the presence of a control bit in th

Strany 43 - Data Format Parameters

Auxiliary Serial Port This group determines the communication through the Auxiliary Serial Port. For this communication mode, RS232interface is auto

Strany 44 - Multidata

Pass Through Options This group allows defining the following parameters: Pass Through mode allows two or more devices to be connected to a sing

Strany 45 - Main Serial Port

barcode enters the reader reading zone. The reader stops reading after an N number of scans without a code. Barcode characters are transmitted on the

Strany 46 - Main Serial Port Parameters

Auxiliary Serial Port Parameters This group allows defining the following parameters: Baud Rate Baud rate is the transmission speed in a commu

Strany 47

Ethernet Ethernet is the most popular physical layer LAN technology in use today. It is the IEEE 802.3 series standard, based onthe CSMA/CD access

Strany 48 - Serial Port

Line Parameters The parameters available in this group define and report the fundamental information about the system. All parametersare listed belo

Strany 49 - Pass Through Options

Services Three different services are available for the Ethernet communication: - Modbus Ethernet Client - Socket - EthernetIP Modbus Ethernet C

Strany 50 - Parameters

The following parameters are available: Data Tx If enabled (checked), it selects the Ethernet User Socket as channel to be used by the scanner

Strany 51 - Ethernet

DeviceNet (if enabled, Main Port is not available) DeviceNet is a low level network that provides connections between simple industrial devices (s

Strany 52 - Line Parameters

Internal Parameters This group allows defining the following parameter: Parameter Updating If checked, it stores the current configuration int

Strany 53 - Services

Bus Communication The parameters available in this group define the fundamental information about the communication: Data Rate It defines the

Strany 54 - EthernetIP

Profibus Profibus is now the world’s most popular Fieldbus. This protocol can handle a large amount of data at high speed andserve the needs of th

Strany 55 - DeviceNet

Bus Communication The parameters available in this group define the fundamental information about the communication: Baud Rate This is a read-

Strany 56 - Internal Parameters

Network Wizard The Network Wizard allows defining the model and number of slave scanners of the Lonworks network. Since this tool is available onl

Strany 57 - Bus Communication

Digital I/O Conditioning This group allows defining the following parameters: Digital Input Lines Input 1 If checked, it allows the PLC to get

Strany 58 - Profibus

Digital I/O Setting This group allows defining the following parameters: Digital Inputs Debouncing Sets the maximum duration of the pulses wh

Strany 59

Outputs Line State Allows the selection of the active state of the output. Each output can be represented with a NPN transistor; this transistor

Strany 60 - Digital I/O Conditioning

Activate on any Diagnostics Error If this parameters is checked, the output will activate when a diagnostic error message is sent. Deactivate wh

Strany 61 - Digital I/O Setting

Local Device Network Settings By selecting the “Local Device Network Settings” from the Device menu, the following dialog box appears allowing todef

Strany 62 - Outputs

Diagnostics When enabled, this group allows selection of the desired diagnostic messages and definition of the relative diagnosticmanagement paramet

Strany 63 - Deactivation Timeout

[97] OSCILLATING MIRROR: Motor Failure – no oscilla

Strany 64

Actions When diagnostics are enabled, this group allows selection of all the parameters managing diagnostic messagetransmission by the Stand Alone o

Strany 65 - Diagnostics

Format This group allows definition of the diagnostic message formatting sent by the Stand Alone or Master scanner to thesystem: The format of

Strany 66

Statistics When enabled, this group allows selection of the desired statistical counters and relative counter separator string to besent to the syst

Strany 67 - Message Position

a. if the slave scanners have been already configured and wired to the network, click on the Autodetect button to start a polling procedure

Strany 68 - GlobalStr

Code Definition This group allows defining the following parameters, which are common to all the code symbologies: Code Combination The Code Com

Strany 69 - Statistics

Examples For all the following examples the No Read Message parameter is set to “Global No Read Message”. - 1 - Code label setting#1 = Code 12