DS6000 Family Software Configuration Parameter Guide - Code Definition - Operating Modes - Reading System Layout
- 4 - Code label setting#1 = Code 93 Code label setting#2 = Interleaved 2/5 Code label setting#3= EAN-8 Code label setting#4= UPC-A Logical Co
Multiple Read Message This string will be sent if, during the reading phase, the scanner reads more than the number of the expected barcodesset by
Code Definition The parameters available in this group define the properties of the code symbology selected. The following table lists allparameters
- Code 128 - EAN/UPC - Code 93 For these symbologies the check digit control is not all
Code Label Local No Read String This is used when the defined code is not read in the reading phase. The Local No Read String is enabled when settingt
Min/Max Code Position These parameters specify where in the scan line a particular code can be found. The scan line is divided into 256physical po
Local No Read Strings This group allows defining a Local No Read string for each group used in the Logical Combination Rule. This group allows defin
Operating Modes The available operating modes are listed below: zOn Line zAutomatic zContinuous zTest zPackTrack™ Operating Modes
On Line This group allows defining the following parameters: In this operating mode, the scanner is connected to an external presence sensor and a
Stop Input Number It defines the number of the input ending the reading phase. Stop Input Active Level Allows the selection of the active state of
Wizard for Quick Reader Setup After installing the Genius™ software program the following window appears asking the user to choose the desiredconfig
Automatic The device does not require connections with external presence sensors in this operating mode. In this mode the scanner is continuously sc
Continuous The device does not require connections with external presence sensors in this operating mode. The reading phase is always active and, di
Test The Test Mode reports information about the reading performance of the laser beam and the code is continuously read. This operating mode allows
PackTrack™ This group allows defining the following parameters: PackTrack™ is a patented operating mode for Datalogic Omni-Directional
This coordinate system is absolute for the reading station, i.e. is valid for all the scanners independently from theirposition or orientation
Encoder Step is 6.35 /2 = 3.175 mm (318) Conveyor Speed This parameter is available only when the Physical Encoder is disabled. It defines the
Minimum Pack Length It defines the minimum length of a pack (mm). Window Dimension The measurement of a barcode position in absolute coordinates p
Reading System Layout This group is available only when working in On-Line, PackTrack™ and Continuous operating modes. Available parameters are the
Reading Parameters This group allows defining the following parameters: Beam Shutter This parameter is active only when the Operating Mode is set
Reconstruction Parameters This group allows defining the following parameters: Max Scan Gap This parameter sets the number of scans without a matc
Test Operating Mode This operating mode causes the reader to be continuously activated allowing to verify its reading features and itsreadin
Scan Line Amplitude This group allows setting the amplitude of scanner laser line in order to illuminate only the desired reading area.Available par
Flash Flash allows to configure the parameters relative the autofocus: Flash Mode This parameter defines the operating mode used by the scanne
Fixed This Flash Mode allows to position the scanner focus exactly on the object containing the barcode label: Fixed Distance This parameter fix
Triggered This Flash Mode allows assigning the desired focus distance to one or more inputs. In this way, upon activation of eachinput the scanner f
NOTE If Input 4 has been already associated to another function (i.e. Presence Sensor), an e
Continuous This Flash Mode allows the scanner focus to dynamically cover the defined reading range where objects containing barcodes are expected. A
DFlash This Flash Mode allows discretizing the total focus distance into eight different focus ranges in order to guarantee themaximum flexibility of
Offset Distance According to the relative positioning between scanner and target code, the minimum detected distance could not beequal to the barcode
Oscillating Mirror This group allows defining the oscillating amplitude of the Oscillating Mirror. Available parameters are the following: Osc
Data Communication Settings This group allows defining the following parameter: The communication may occur through: - Crisplant Para
On Line Operating Mode This operating mode causes the reader to be connected to an external Presence Sensor using EXT TRIG+ and EXTTRIG- inputs.
Crisplant Parameters This group allows defining all the parameters managing this communication protocol: Crisplant Manufacturer ID It defines
Data Format Data Format allows to configure the parameters relative to the message format and the transmission mode: Header Tx Start It select
Standard Parameters Available parameters for this group are the following: Header String Headers (up to 128 bytes) can be defined and transmitte
Code Field Length Setting The code field length can be (in number of characters/digits) can be specified in order to be accepted for decoding:
Multidata When a Master MULTIDATA configuration is selected, this group allows the Slave address to be included before theSlave message together wit
Main Serial Port This option determines the communication between the scanner and the Host, or, in a multi-sided layout, between several scanners an
Main Serial Port Parameters This group allows defining all parameters managing the serial communication: Main Port Communication Mode The foll
Baud Rate Baud rate is the transmission speed in a communication line. Parity Parity is a parameter indicating the presence of a control bit in th
Auxiliary Serial Port This group determines the communication through the Auxiliary Serial Port. For this communication mode, RS232interface is auto
Pass Through Options This group allows defining the following parameters: Pass Through mode allows two or more devices to be connected to a sing
barcode enters the reader reading zone. The reader stops reading after an N number of scans without a code. Barcode characters are transmitted on the
Auxiliary Serial Port Parameters This group allows defining the following parameters: Baud Rate Baud rate is the transmission speed in a commu
Ethernet Ethernet is the most popular physical layer LAN technology in use today. It is the IEEE 802.3 series standard, based onthe CSMA/CD access
Line Parameters The parameters available in this group define and report the fundamental information about the system. All parametersare listed belo
Services Three different services are available for the Ethernet communication: - Modbus Ethernet Client - Socket - EthernetIP Modbus Ethernet C
The following parameters are available: Data Tx If enabled (checked), it selects the Ethernet User Socket as channel to be used by the scanner
DeviceNet (if enabled, Main Port is not available) DeviceNet is a low level network that provides connections between simple industrial devices (s
Internal Parameters This group allows defining the following parameter: Parameter Updating If checked, it stores the current configuration int
Bus Communication The parameters available in this group define the fundamental information about the communication: Data Rate It defines the
Profibus Profibus is now the world’s most popular Fieldbus. This protocol can handle a large amount of data at high speed andserve the needs of th
Bus Communication The parameters available in this group define the fundamental information about the communication: Baud Rate This is a read-
Network Wizard The Network Wizard allows defining the model and number of slave scanners of the Lonworks network. Since this tool is available onl
Digital I/O Conditioning This group allows defining the following parameters: Digital Input Lines Input 1 If checked, it allows the PLC to get
Digital I/O Setting This group allows defining the following parameters: Digital Inputs Debouncing Sets the maximum duration of the pulses wh
Outputs Line State Allows the selection of the active state of the output. Each output can be represented with a NPN transistor; this transistor
Activate on any Diagnostics Error If this parameters is checked, the output will activate when a diagnostic error message is sent. Deactivate wh
Local Device Network Settings By selecting the “Local Device Network Settings” from the Device menu, the following dialog box appears allowing todef
Diagnostics When enabled, this group allows selection of the desired diagnostic messages and definition of the relative diagnosticmanagement paramet
[97] OSCILLATING MIRROR: Motor Failure – no oscilla
Actions When diagnostics are enabled, this group allows selection of all the parameters managing diagnostic messagetransmission by the Stand Alone o
Format This group allows definition of the diagnostic message formatting sent by the Stand Alone or Master scanner to thesystem: The format of
Statistics When enabled, this group allows selection of the desired statistical counters and relative counter separator string to besent to the syst
a. if the slave scanners have been already configured and wired to the network, click on the Autodetect button to start a polling procedure
Code Definition This group allows defining the following parameters, which are common to all the code symbologies: Code Combination The Code Com
Examples For all the following examples the No Read Message parameter is set to “Global No Read Message”. - 1 - Code label setting#1 = Code 12
Komentáře k této Příručce