SC6000
46
3
3.4 PARAMETER DEFAULT VALUES
The following table contains the list of the factory default settings for the SC6000 Controller.
Genius™ also allows checking the parameter default values by selecting the “Compare
parameters” option available in the Tools menu and comparing the current SC6000
configuration to the default one.
Parameter Default Setting
Code Definition
Code Combination Single Label
No Read Message Global No Read Message
No Read String (128 characters max) <CAN>
Partial Read is Treated As Partial Read
Multi Filters Disabled (unchecked)
Code Label Settings#1
Enable Enabled (checked)
Code Symbology Interleaved 2 of 5
Label Length 8
Min Code Position 0
Max Code Position 255
CheckDigit Disabled (unchecked)
Pattern Match String (200 char. max) NULL
Code Label Settings#2
Enable Enabled (checked)
Code Symbology Code39
Label Length Variable
Minimum Label Length 1
Maximum Label Length 60
Min Code Position 0
Max Code Position 255
CheckDigit Disabled (unchecked)
Pattern Match String (200 char. max.) NULL
Operating Modes
Operating Mode Selection PackTrack
Physical Encoder Enabled (checked)
Encoder Step 400
PS Line 0
Presence Sensor Input PS
Presence Sensor Input Level Active Closed
Distance from PS Line to Tx Line 2500
Transmission Edge Trailing
Max Number of Packs 10
Minimum Distance Error Behaviour Compose
Minimum Distance between Packs 30
Minimum Pack Length Error Behaviour Discard Item
Minimum Pack Length 50
Window Dimension 15
Encoder Delay Error Behaviour Safe Resync