READING FEATURES
89
7
7.2.2 Picket-Fence Mode
If scanning is parallel to the code motion, (Figure 106), the number of effective scans is given
by the following formula:
SN = [((FW-LW)/LS)
*
SS] -2 Where: SN = number of effective scans
FW = reading field width (in mm)
LW = label width (in mm)
LS = label movement speed (in mm/s)
SS = scans per second
Figure 106 - "Picket-Fence" Scanning Mode
For example, for a 100 mm wide code moving in a point where the reading field is 200 mm
wide at a 2000 mm/s speed, the DS2400N (800 scans per sec.), performs:
[((200-100)/2000)
*
800] - 2 = 38 effective scans
Laser beam
DS2400N
FW
LW
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]