Datalogic Magellan 3300HSi Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Čtečky čárových kódů Datalogic Magellan 3300HSi. Datalogic Magellan 3300HSi Programming instructions Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 208
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - Product Reference Guide

MagellanTM 3300HSiIn-Counter Horizontal Single Plane ScannerProduct Reference Guide

Strany 2

Getting Started2MagellanTM 3300HSiConnecting the ScannerThe scanner kit you ordered to match your interface should provide a compatible cable for your

Strany 3 - Table of Contents

Symbologies92MagellanTM 3300HSiEAN-13The following options apply to the EAN-13 symbology.Disable/Enable EAN-13When disabled, the scanner will not read

Strany 4 - 3200VSi

EAN-13Product Reference Guide 93EAN-13 — continuedEAN-13 Flag 1 CharacterEnables/disables transmission of an EAN/JAN13 Flag

Strany 5 - Product Reference Guide 3

Symbologies94MagellanTM 3300HSiEAN-8The following options apply to the EAN-8 symbology.Disable/Enable EAN-8When disabled, the scanner will not read EA

Strany 6

EAN-8Product Reference Guide 95EAN-8 — continuedExpand EAN-8 to EAN-13— Expands EAN-8 data to the EAN-13 data format. Selec

Strany 7

Symbologies96MagellanTM 3300HSiEAN Two-LabelEnables/disables the ability of the scanner to decode EAN two-label pairs.START / ENDPROGRAMMING bar codes

Strany 8

Price Weight Check DigitProduct Reference Guide 97Price Weight Check DigitEnables/disables calculation and verification of

Strany 9 - Getting Started

Symbologies98MagellanTM 3300HSiAdd-onsAdd-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes. The scanner will read t

Strany 10 - Connecting the Scanner

Add-onsProduct Reference Guide 99Add-ons — continuedSTART / ENDPROGRAMMING bar codesDisable Optional 2-Digit Add-onsDEFAULT

Strany 11

Symbologies100MagellanTM 3300HSiGS1 DataBar Omnidirectional / Stacked OmnidirectionalThe following options apply to the GS1 DataBar Omnidirectional sy

Strany 12 - Installation

GS1 DataBar Expanded / Expanded StackedProduct Reference Guide 101GS1 DataBar Expanded / Expanded StackedThe following opti

Strany 13 - Figure 3. Countertop Cutouts

Connecting the ScannerProduct Reference Guide 3USB Connection — Connect the scanner to a USB port on the terminal/PC using

Strany 14 - LED and Beeper Indicators

Symbologies102MagellanTM 3300HSiGS1 DataBar Expanded / Expanded Stacked — continuedLength ControlFixed Length Decoding— When fixed length decoding is

Strany 15

GS1 DataBar Expanded / Expanded StackedProduct Reference Guide 103GS1 DataBar Expanded / Expanded Stacked — continuedCoupon

Strany 16 - Programming

Symbologies104MagellanTM 3300HSiGS1 DataBar LimitedThe following options apply to the GS1 DataBar Limited symbology.Disable/Enable GS1 DataBar Limited

Strany 17 - Bar Code Mask

Code 39Product Reference Guide 105Code 39The following options apply to the Code 39 symbology.Disable/Enable Code 39When th

Strany 18 - LED Class

Symbologies106MagellanTM 3300HSiCheck Character TransmitEnable this option to transmit the check character with scanned bar code data.START / ENDPROGR

Strany 19 - General Features

Code 39Product Reference Guide 107Code 39 Full ASCIIEnables/disables the translation of Code 39 characters to Code 39 full-

Strany 20

Symbologies108MagellanTM 3300HSiCode 39 — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will decode

Strany 21 - Composite label

Code 32 Italian PharmacodeProduct Reference Guide 109Code 32 Italian PharmacodeThe following options apply to the Code 32 I

Strany 22 - Scanner Button Options

Symbologies110MagellanTM 3300HSiCode 32 Italian Pharmacode — continuedCheck Character TransmitEnable this option to transmit the check character with

Strany 23 - Camera Button Mode

Code 128Product Reference Guide 111Code 128The following options apply to the Code 128 symbology.Disable/Enable Code 128Whe

Strany 24 - LED Level

Getting Started4MagellanTM 3300HSiError CodesIf an error is detected, the scanner will sound a long low tone (for three seconds) and flash its LED, in

Strany 25 - Auxiliary Port Mode

Symbologies112MagellanTM 3300HSiCode 128 — continuedTransmit Function CharactersEnables/disables transmission of Code 128 function characters 1, 2, 3,

Strany 26 - Auxiliary Port Baud Rate

Code 128Product Reference Guide 113Code 128 — continuedLength ControlFixed Length Decoding— When fixed length decoding is e

Strany 27 - PROGRAMMING bar codes

Symbologies114MagellanTM 3300HSiCode 128 Conversion to Code 39Enables/disables expansion of Code 128 labels to Code 39.START / ENDPROGRAMMING bar code

Strany 28 - Sleep Mode

Interleaved 2 of 5Product Reference Guide 115Check Digit CalculationWhen enabled, the scanner will calculate the check digi

Strany 29 - Sleep Mode — cont

Symbologies116MagellanTM 3300HSiInterleaved 2 of 5 — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner

Strany 30 - Wake Up Intensity

CodabarProduct Reference Guide 117CodabarThe following options apply to the Codabar symbology.Disable/Enable CodabarWhen th

Strany 31 - Wake Up Intensity — cont

Symbologies118MagellanTM 3300HSiCheck Character TransmitEnable this option to transmit the check character with scanned bar code data.START / ENDPROGR

Strany 32

CodabarProduct Reference Guide 119Codabar — continuedLength ControlFixed Length Decoding— When fixed length decoding is ena

Strany 33 - ERI Timeout

Symbologies120MagellanTM 3300HSiCodabar — continuedStart/Stop Character TypeCodabar has four pairs of Start/Stop patterns. Select one pair to match yo

Strany 34 - Good Read: When to Indicate

Code 93Product Reference Guide 121Start/Stop Character MatchThis feature enables/disables the requirement that start and st

Strany 35 - Good Read Beep Frequency

InstallationProduct Reference Guide 56. Connect the interface cable to the terminal.7. If required, connect the scanner’s A

Strany 36 - Good Read Beep Length

Symbologies122MagellanTM 3300HSiCode 93 — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will decode

Strany 37 - Good Read Beep Volume

MSIProduct Reference Guide 123MSIThe following options apply to the MSI symbology.Disable/Enable MSIWhen this feature is di

Strany 38 - Cell Phone Mode

Symbologies124MagellanTM 3300HSiMSI — continuedMSI Check Character CalculationEnables/disables calculation and verification of optional MSI check char

Strany 39 - Image Capture

MSIProduct Reference Guide 125MSI — continuedMSI Length ControlSpecifies either variable-length decoding or fixed-length de

Strany 40

Symbologies126MagellanTM 3300HSiNOTES

Strany 41

Product Reference Guide1272D SymbologiesNOTEThe features in this section are available ONLY for models with 2D fea-tures activated.2D SymbologiesThe s

Strany 42 - Image Format

2D Symbologies128MagellanTM 3300HSiPDF 417Disable/Enable PDF 417When disabled, the scanner will not read PDF 417 bar codes.START / ENDPROGRAMMING bar

Strany 43 - Image Size

2D SymbologiesProduct Reference Guide 129PDF 417 — continuedLength ControlFixed Length Decoding— When fixed length decoding

Strany 44 - Image Contrast

2D Symbologies130MagellanTM 3300HSiPDF 417 — continuedPDF 417 Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan either the

Strany 45 - Interface Related Features

2D SymbologiesProduct Reference Guide 131Micro PDF 417Disable/Enable Micro PDF 417When disabled, the scanner will not read

Strany 46

Getting Started6MagellanTM 3300HSiLED and Beeper IndicatorsThe scanner’s beeper sounds and its green LED illuminates to indicate various functions or

Strany 47 - Interface Selection

2D Symbologies132MagellanTM 3300HSiMicro PDF 417 — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner wi

Strany 48 - Interface Selection — cont

2D SymbologiesProduct Reference Guide 133Micro PDF 417 — continuedMicro PDF 417 Length 1, Length 2 Programming Instructions

Strany 49 - Interface Features

2D Symbologies134MagellanTM 3300HSiDatamatrixDisable/Enable DatamatrixWhen disabled, the scanner will not read Datamatrix bar codes.START / ENDPROGRAM

Strany 50 - Interface Features — cont

2D SymbologiesProduct Reference Guide 135Datamatrix — continuedLength ControlFixed Length Decoding— When fixed length decod

Strany 51 - RS-232 Interface Features

2D Symbologies136MagellanTM 3300HSiDatamatrix — continuedDatamatrix Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan eith

Strany 52

2D SymbologiesProduct Reference Guide 137QR CodeDisable/Enable QR CodeWhen disabled, the scanner will not read QR Code labe

Strany 53 - Hardware Flow Control

2D Symbologies138MagellanTM 3300HSiQR Code — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will dec

Strany 54 - Intercharacter Delay

2D SymbologiesProduct Reference Guide 139QR Code — continuedQR Code Length 1, Length 2 Programming Instructions1. Scan the

Strany 55 - Software Flow Control

2D Symbologies140MagellanTM 3300HSiMaxicodeDisable/Enable MaxicodeWhen disabled, the scanner will not read Maxicode labels.START / ENDPROGRAMMING bar

Strany 56 - Host Echo

2D SymbologiesProduct Reference Guide 141Maxicode — continuedLength ControlFixed Length Decoding— When fixed length decodin

Strany 57 - Host Echo Quiet Interval

LED and Beeper IndicatorsProduct Reference Guide 7LED and Beeper Indicators — cont.Table 2. Beeper FunctionsBEEPER INDICATI

Strany 58 - Signal Voltage: Normal/TTL

2D Symbologies142MagellanTM 3300HSiMaxicode — continuedMaxicode Length 1, Length 2 Programming Instructions1. Scan the START bar code.2. Scan either t

Strany 59 - Beep on ASCII BEL

2D SymbologiesProduct Reference Guide 143AztecDisable/Enable AztecWhen disabled, the scanner will not read Aztec labels.STA

Strany 60 - Beep on Not on File

2D Symbologies144MagellanTM 3300HSiAztec — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will decod

Strany 61 - ACK NAK Options

2D SymbologiesProduct Reference Guide 145Aztec — continuedAztec Length 1, Length 2 Programming Instructions1. Scan the STAR

Strany 62 - NAK Character

2D Symbologies146MagellanTM 3300HSiComposite LabelsDisable/Enable GS1 DataBar Omnidirectional 2D ComponentWhen enabled, if a GS1 DataBar Omnidirection

Strany 63 - ACK NAK Timeout Value

2D SymbologiesProduct Reference Guide 147Disable/Enable GS1 DataBar Limited 2D ComponentWhen enabled, if a GS1 DataBar Limi

Strany 64 - ACK NAK Retry Count

2D Symbologies148MagellanTM 3300HSiNOTES

Strany 65 - ACK NAK Error Handling

Product Reference Guide149Advanced Decoding FeaturesInverse Label ReadingThis controls the method of reading inverse labels (white label on black back

Strany 66 - Single Cable RS-232

Advanced Decoding Features150MagellanTM 3300HSiUPC/EAN Quiet ZoneThis feature sets a Quiet Zone requirement for UPC/EAN labels.START / ENDPROGRAMMING

Strany 67 - RTS CTS Selection =

Product Reference Guide151Chapter 9ReferencesThis section contains explanations and examples of selected bar code features. See the program-ming secti

Strany 68 - Single Cable RS-232 Use BCC

Getting Started8MagellanTM 3300HSiProgrammingThe scanner is typically factory-configured with a set of default features standard to the interface type

Strany 69 - Single Cable RS-232 Use STX

References152MagellanTM 800iGlobal Prefix/SuffixUp to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/or as

Strany 70 - Single Cable RS-232 Use ETX

Label IDProduct Reference Guide 153Label IDA Label ID is used to identify a bar code (symbology) type. See Appendix D, Fact

Strany 71 - Single Cable Pacesetter Plus

References154MagellanTM 800iLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the labe

Strany 72 - USB-OEM Interface Features

Product Reference Guide155Appendix AProduct SpecificationsOptical and Read Performance ParametersParameter SpecificationMinimum Resolution 5 milMinimu

Strany 73 - USB Keyboard

156MagellanTM 3300HSiPhysical PropertiesParameter SpecificationDimensions (Scanner only): 6” x 6” x 3.42” (WxHxD)Weight (Scanner) 1 lb 4.6 oz (0.584kg

Strany 74 - Keyboard Wedge — cont

Product Reference Guide157Appendix BCable PinoutsStandard Cable Pinouts (Primary Interface Cables)Pin # RS-232IBM Port 5B/9B/17USB-OEMUSB,USB Keyboard

Strany 75

158MagellanTM 3300HSiNOTES

Strany 76

ABCDEF Product Reference Guide159Appendix CAlpha-Numeric Pad

Strany 77 - Disable Control Characters

160MagellanTM 3300HSiAlpha-Numeric Pad1230987654NOTENote for numeric entry sequences, the scanner will announce the number of digits remaining to be e

Strany 78

Product Reference Guide161Appendix DFactory Default SettingsFactory Defaults by InterfaceThe following is a partial list of key settings for each inte

Strany 79 - USB COM Interface Set-up

Bar Code MaskProduct Reference Guide 9Bar Code MaskCut a hole in this page and remove it from the manual as indicated to cr

Strany 80

162MagellanTM 3300HSiStop Bits1 1 1 1 1 1ParityNone None None None None NoneHardware Flow ControlDisable Disable Disable Disable Disable DisableInterc

Strany 81 - Data Editing

Factory Defaults by InterfaceProduct Reference Guide 163IBM Transmit Labels in Code 39 FormatDisableKeyboard LayoutUSACaps

Strany 82

164MagellanTM 3300HSiEAN Two-LabelDisable Disable Disable Disable Disable DisableEAN Two-Label Combined TransmissionDisable Disable Disable Disable Di

Strany 83

Factory Defaults by InterfaceProduct Reference Guide 165Check Digit CalculationDisable Disable Disable Disable Disable Disa

Strany 84

166MagellanTM 3300HSiDisable/Enable GS1 DataBar Omnidirec-tional 2D ComponentDisable Disable Disable Disable Disable DisableDisable/Enable GS1 DataBar

Strany 85 - Label ID — cont

Product Reference Guide167Appendix EKeyboard Function Key MappingsKeyboard Model Cross ReferenceTable 1 summarizes the keyboard models, their defined

Strany 86

168MagellanTM 3300HSiTable 2. USB Function Key Usage MapASCII Key value Usage NameModifier/Scancode02 STX F11 00h 44h03 ETX F12 00h 45h04 EOT GUI

Strany 87

Keyboard Model Cross ReferenceProduct Reference Guide 169Table 3ASCII (hex)ASCII code Key Scancode02 STX ALT left Make 3

Strany 88

170MagellanTM 3300HSiTable 5ASCII (hex)ASCII code Key Scancode02 STX ALT left Make 19h 03 ETX ALT left Break F0h 19h04 EOT CTRL left Make 11h05 ENQ

Strany 89

Keyboard Model Cross ReferenceProduct Reference Guide 171Table 6. ASCII (hex)ASCII codeKey Scancode02 STX ALT left Make 19

Strany 90 - Case Conversion

Getting Started10MagellanTM 3300HSiGoing GreenThank you for using the bar code mask on the opposite side of this page. This manual has been formatted

Strany 91 - Character Conversion

172MagellanTM 3300HSiTable 7. ASCII value ASCII code Key Scancode02h STX ALT left Make 31h03h ETX ALT left Break B1h04h EOT CTRL left Make 41h05h E

Strany 92

Keyboard Model Cross ReferenceProduct Reference Guide 173Table 8. NEC 9801-Key Function Key MapASCII value ASCII code Key S

Strany 93 - Chapter 6

174MagellanTM 3300HSiNOTES

Strany 94 - UPC-A — continued

Product Reference Guide175Appendix FHost CommandsAccepting RS-232 CommandsThe scanner responds to the following RS-232 commands:COMMAND ASCII HEX COMM

Strany 95

176MagellanTM 3300HSiNOTES

Strany 96 - Disable/Enable UPC-E

Product Reference Guide177Appendix GSample Symbols1D Symbol Samples0 1234567890UPC-A051234567890Interleaved 2 of 5Code 128Code 1289 780330 290951EA

Strany 97 - UPC-E — continued

178MagellanTM 3300HSi1D Symbol Samples — continued0100123456789050GS1 DataBar Expanded(01)00123456789012GS1 DataBar Omnidirectional123456Code 2 of 5

Strany 98

2D Sample SymbolsProduct Reference Guide 1792D Sample Symbols

Strany 99 - Expand UPC/EAN to GTIN

180MagellanTM 3300HSiComposite Sample SymbolsGS1 DataBar Limited CompositeGS1 DataBar Truncated Composite

Strany 100 - Check Digit Transmission

Product Reference Guide181Appendix HmicroSD CardmicroSDHC CompatibilityAt the time of this writing, the microSD card interface for this product suppor

Strany 101 - EAN-13 — continued

Product Reference Guide11Chapter 2General FeaturesDouble Read Timeout for Linear LabelsThis Double Read Timeout feature sets a time limit that determi

Strany 102 - Disable/Enable EAN-8

182MagellanTM 3300HSimicroSD Card Removal1. Push in gently using your finger or thumbnail to dis-engage and remove the microSD card. Remember to keep

Strany 103 - EAN-8 — continued

microSD Function DetailsProduct Reference Guide 183microSD Function Details From Scanner to microSD CardCapture and save an

Strany 104 - EAN Two-Label

184MagellanTM 3300HSiBy scanning a label1. Insert the microSD card into the scanner 2. Scan the status export label <FNC3>STATUS<CR>3.

Strany 105 - Price Weight Check Digit

microSD Function DetailsProduct Reference Guide 185Configuration load to scanner By Autorun file1. Generate a text file by

Strany 106 - Symbologies

186MagellanTM 3300HSiNOTES

Strany 107 - Add-ons — continued

Product Reference Guide187Appendix IHandheld Data Format RequirementsThis appendix provides application notes to describe the general format of data t

Strany 108 - UCC/EAN 128 Emulation

188MagellanTM 3300HSiDatalogic Handheld Data Format RequirementsThe following sections describe label transmission formats that are typically observed

Strany 109 - GS1-128 Emulation

Product Reference Guide 189• Prefix must be an ASCII character 'A' - total length including prefix must be greate

Strany 110 - Length Control

190MagellanTM 3300HSiUPC-E with 2-Digit Supplemental• Number system must be included in label data.• Check digit must be included in label data and is

Strany 111 - Coupon Read Control

Product Reference Guide 191EAN-8• Check digit must be included in label data and is assumed to be correct• Prefix must be a

Strany 112 - GS1 DataBar Limited

Datalogic ADC, Inc.959 Terry StreetEugene, OR 97402USATelephone: (541) 683-5700Fax: (541) 345-7140© 2010-2014 Datalogic ADC, Inc.An Unpublished Work -

Strany 113 - Check Character Calculation

General Features12MagellanTM 3300HSiDouble Read Timeout for Linear Labels — cont.START / ENDPROGRAMMING bar codes0.7 Second0.8 Second0.9 Second1 Secon

Strany 114 - Start/Stop Characters

192MagellanTM 3300HSi• Example: 'F110123456789112345'.EAN-13 with Code 128 Supplemental• Check digit must be included in label data and is a

Strany 115 - Code 39 Full ASCII

Product Reference Guide 193Codabar• Check character must be included in label data.• Label length including check character

Strany 116 - Code 39 — continued

194MagellanTM 3300HSiMSI• Check character must be included in label data.• Label length including check character and excluding prefix character must

Strany 117 - Code 32 Italian Pharmacode

Product Reference Guide 195AIM FormatsAIM specifies a 3-character string that is attached as a prefix to the label data for

Strany 118

196MagellanTM 3300HSi5-Digit Supplemental• Supplemental data is appended to any EAN base label.• Prefix must be ASCII characters ']E2'.• Len

Strany 119 - Code 128

Product Reference Guide 197Codabar• Check character must be included in label data.• Label length including check character

Strany 120 - Code 128 — continued

198MagellanTM 3300HSiI 2 of 5• Check character must be included in label data.• Label length including check characters and excluding prefix character

Strany 121

ASCII Character SetThe table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed

Strany 122 - Interleaved 2 of 5

820037414 (Rev.G) February 2014www.datalogic.com© 2010-2014 Datalogic ADC, Inc. • All rights reserved. • Datalogic and the Datalogic logo are registe

Strany 123 - Check Digit Transmit

Double Read Timeout for 2D LabelsProduct Reference Guide 13Double Read Timeout for 2D LabelsThis Double Read Timeout featur

Strany 124

General Features14MagellanTM 3300HSiScanner Button OptionsThis feature allows the user to configure the scanner / volume button (which is accessible

Strany 125 - Check Character Verification

Camera Button ModeProduct Reference Guide 15Camera Button ModeControls the function associated with the "Picture Takin

Strany 126

General Features16MagellanTM 3300HSiLED LevelThis feature defines the LED intensity level by pulse width.START / ENDPROGRAMMING bar codesLED Level =

Strany 127 - Codabar — continued

Auxiliary Port ModeProduct Reference Guide 17Auxiliary Port ModeSpecifies the function associated with the auxillary interf

Strany 128

General Features18MagellanTM 3300HSiAuxiliary Port Baud RateSpecifies baud rate of auxillary port when operating in PIR/CT mode.START / ENDPROGRAMMING

Strany 129 - Disable/Enable Code 93

Productivity Index Reporting (PIR)Product Reference Guide 19Productivity Index Reporting (PIR)When PIR is enabled, label qu

Strany 130 - Code 93 — continued

General Features20MagellanTM 3300HSiSleep ModeThis feature specifies the amount of time with no bar code reads before the scanner enters sleep mode.ST

Strany 131 - MSI Check Character Transmit

Sleep ModeProduct Reference Guide 21Sleep Mode — cont.START / ENDPROGRAMMING bar codes6 Minutes7 Minutes8 Minutes9 Minutes1

Strany 132 - MSI — continued

Product Reference Guide 1Table of ContentsChapter 1. Getting Started...

Strany 133

General Features22MagellanTM 3300HSiWake Up IntensityThis feature indicates the percentage of ambient light change which will trigger the scanner to w

Strany 134

Sleep ModeProduct Reference Guide 23Wake Up Intensity — cont.START / ENDPROGRAMMING bar codes13%14%15%

Strany 135 - 2D Symbologies

General Features24MagellanTM 3300HSiLED and Beeper IndicatorsPower On AlertDisables or enables the indication (a single beep) that the scanner has fin

Strany 136 - Disable/Enable PDF 417

LED and Beeper IndicatorsProduct Reference Guide 25ERI TimeoutSpecifies the amount of time the External Read Indicator (ERI

Strany 137 - PDF 417 — continued

General Features26MagellanTM 3300HSiGood Read: When to IndicateThis feature specifies when the scanner will provide indication (beep and/or flash its

Strany 138

LED and Beeper IndicatorsProduct Reference Guide 27Good Read Beep ControlThis feature enables/disables the scanner’s abilit

Strany 139 - Micro PDF 417

General Features28MagellanTM 3300HSiGood Read Beep LengthSpecifies the duration of a good read beep.START / ENDPROGRAMMING bar codes60msec 80msecDEFA

Strany 140 - Micro PDF 417 — continued

LED and Beeper IndicatorsProduct Reference Guide 29Good Read Beep VolumeSelects the beeper volume (loudness) upon a good re

Strany 141

General Features30MagellanTM 3300HSiCell Phone ModeCell Phone Mode enables the scanner to read bar codes on a cell phone display. (See Camera But-ton

Strany 142 - Datamatrix

Product Reference Guide31Chapter 3Image CaptureImage CaptureHow to Capture an ImageThere are two methods of capturing images as discussed below:•Image

Strany 143 - Datamatrix — continued

2MagellanTM 3200VSiSoftware Flow Control ...

Strany 144

Image Capture32MagellanTM 3300HSiImage Capture to the Host by Host CommandThis feature is only available for RS-232 and USB COM interfaces.NOTEIf the

Strany 145 - Disable/Enable QR Code

Image CaptureProduct Reference Guide 33Image Capture to a microSD Card by Optional Remote Camera Button PressNOTEThis featu

Strany 146 - QR Code — continued

Image Capture34MagellanTM 3300HSiImage CompressionSpecifies the starting image compression factor for JPEG images. A higher number specifies a higher

Strany 147

Image SizeProduct Reference Guide 35Image SizeSpecifies the size of the image capture. Choices are:•VGA•WVGA•SXGA, Full Siz

Strany 148 - Maxicode

Image Capture36MagellanTM 3300HSiImage BrightnessThis feature sets the image brightness value. Follow these instructions to configure this feature:1.

Strany 149 - Maxicode — continued

Product Reference Guide37Chapter 4Interface Related FeaturesAt the time of this writing, the reader supports the interfaces listed in Table 4-1. Selec

Strany 150

Interface Related Features38MagellanTM 3300HSiTable 4-2I/F TypePCs SupportedAPC/XT w/Alternate Key EncodingBAT, PS/2 25-286, 30-286, 50, 50Z, 60, 70,

Strany 151 - Disable/Enable Aztec

Interface SelectionProduct Reference Guide 39Interface SelectionSTART / ENDPROGRAMMING bar codesRS-232 StandardRS-232 Winco

Strany 152 - Aztec — continued

Interface Related Features40MagellanTM 3300HSiInterface Selection — cont.START / ENDPROGRAMMING bar codesKeyboard Wedge AKeyboard Wedge BKeyboard Wedg

Strany 153

Interface FeaturesProduct Reference Guide 41Interface FeaturesObey/Ignore Host CommandsWhen set to ignore host commands, th

Strany 154 - Composite Labels

Product Reference Guide 3ISBN ...

Strany 155 - 147

Interface Related Features42MagellanTM 3300HSiInterface Features — cont.Host Transmission BuffersSpecifies the number of host transmission(s) that may

Strany 156

Interface FeaturesProduct Reference Guide 43RS-232 Interface FeaturesSTART / ENDPROGRAMMING bar codesBuad Rate 1200 Baud240

Strany 157 - Advanced Decoding Features

Interface Related Features44MagellanTM 3300HSiRS-232 Interface Features — cont.START / ENDPROGRAMMING bar codesData Bits7 Data Bits8 Data BitsDEFAULTS

Strany 158 - UPC/EAN Quiet Zone

Interface FeaturesProduct Reference Guide 45RS-232 Interface Features — cont.Hardware Flow ControlDisable Hardware Control—

Strany 159 - References

Interface Related Features46MagellanTM 3300HSiRS-232 Interface Features — cont.Intercharacter DelayThis delay is inserted after each data character tr

Strany 160 - Global Prefix/Suffix

Interface FeaturesProduct Reference Guide 47Intercharacter Delay — cont.Software Flow ControlDisables/Enables software cont

Strany 161 - Label ID

Interface Related Features48MagellanTM 3300HSiRS-232 Interface Features — cont.Host EchoWhen enabled, this feature passes all data through the scanner

Strany 162

Interface FeaturesProduct Reference Guide 49RS-232 Interface Features — cont.Host Echo Quiet IntervalThis setting specifies

Strany 163 - Product Specifications

Interface Related Features50MagellanTM 3300HSiHost Echo Quiet Interval — cont.Signal Voltage: Normal/TTLSpecifies whether the RS-232 interface provide

Strany 164 - Other Parameters

Interface FeaturesProduct Reference Guide 51RS-232 InvertEnables/disables inversion of RS-232 TXD and RXD signals.START / E

Strany 165 - Cable Pinouts

4MagellanTM 3200VSiMSI Check Character Calculation ...

Strany 166

Interface Related Features52MagellanTM 3300HSiBeep on Not on FileSelect for the host to beep (or not) when a not-on-file (host command) condition is d

Strany 167 - Alpha-Numeric Pad

Interface FeaturesProduct Reference Guide 53ACK NAK OptionsThis enables/disables the ability of the scanner to support the

Strany 168

Interface Related Features54MagellanTM 3300HSiRS-232 Interface Features — cont.ACK CharacterSTART / ENDPROGRAMMING bar codesSets the ACK character fro

Strany 169 - Factory Default Settings

Interface FeaturesProduct Reference Guide 55RS-232 Interface Features — cont.Retry on ACK NAK TimeoutEnables/disables retry

Strany 170

Interface Related Features56MagellanTM 3300HSiRS-232 Interface Features — cont.ACK NAK Retry CountSTART / ENDPROGRAMMING bar codesThis feature sets th

Strany 171

Interface FeaturesProduct Reference Guide 57RS-232 Interface Features — cont.ACK NAK Error HandlingThis item specifies the

Strany 172

Interface Related Features58MagellanTM 3300HSiRS-232 Interface Features — cont.Transmission Failure IndicationEnables/disables bad-label indication up

Strany 173

Single Cable RS-232Product Reference Guide 59Single Cable RS-232 RTS CTS SelectionSpecifies how RTS and CTS are used to con

Strany 174

Interface Related Features60MagellanTM 3300HSiSingle Cable RS-232 Use BCCEnables/disables the ability of the scanner to use BCC.START / ENDPROGRAMMING

Strany 175 - Appendix E

Single Cable RS-232Product Reference Guide 61Single Cable RS-232 Use STXEnables/disables the ability of the scanner to use

Strany 176

Product Reference Guide 5Appendix C. Alpha-Numeric Pad ...

Strany 177

Interface Related Features62MagellanTM 3300HSiSingle Cable RS-232 Use ETXEnables/disables the ability of the scanner to use ETX.START / ENDPROGRAMMING

Strany 178

Single Cable RS-232Product Reference Guide 63Single Cable Pacesetter PlusEnables/disables sending Pacesetter Plus informati

Strany 179 - Table 6

Interface Related Features64MagellanTM 3300HSiUSB-OEM Interface FeaturesUSB-OEM Device usageThe USB-OEM protocol allows for the scanner to be identifi

Strany 180 - Japanese DOS Function Key Map

Single Cable RS-232Product Reference Guide 65Keyboard WedgeandUSB KeyboardAs a keyboard interface, the scanner supports mos

Strany 181 - 173

Interface Related Features66MagellanTM 3300HSiKeyboard Wedge — cont.START / ENDPROGRAMMING bar codesItalyNorwayPortugalSpainSwedenSwitzerlandJapan 106

Strany 182

Single Cable RS-232Product Reference Guide 67Keyboard Wedge — cont.Caps Lock StateSpecifies the format in which the scanner

Strany 183 - Host Commands

Interface Related Features68MagellanTM 3300HSiKeyboard Wedge — cont.Power-On SimulationNOTEThis feature does not apply to the USB Keyboard interface.A

Strany 184

Single Cable RS-232Product Reference Guide 69Control CharactersSpecifies how the scanner transmits ASCII control characters

Strany 185 - Sample Symbols

Interface Related Features70MagellanTM 3300HSiKeyboard Wedge — cont.Wedge Quiet IntervalNOTEThis feature does not apply to the USB Keyboard inter-face

Strany 186 - 1D Symbol Samples — continued

USB COM Interface Set-upProduct Reference Guide 71Keyboard Wedge — cont.Intercharacter DelaySTART / ENDPROGRAMMING bar code

Strany 187 - 2D Sample Symbols

6MagellanTM 3200VSiUPC-A ...

Strany 188 - Composite Sample Symbols

Interface Related Features72MagellanTM 3300HSiNOTES

Strany 189 - Appendix H

Product Reference Guide73Chapter 5Data EditingData Editing OverviewCAUTIONIt is not recommended to use these features with IBM interfaces.When a bar

Strany 190 - Autorun File Processing

Data Editing74MagellanTM 3300HSiGlobal Prefix/SuffixSTART / ENDPROGRAMMING bar codesSets up to 20 characters each from the set of ASCII characters or

Strany 191 - From Scanner to microSD Card

AIM IDProduct Reference Guide 75AIM IDAIM (Automatic Identification Manufacturers) label identifiers are assigned from a gl

Strany 192 - From microSD Card to Scanner

Data Editing76MagellanTM 3300HSiLabel IDSTART / ENDPROGRAMMING bar codesLabel ID Position Label ID Transmission: DisableLabel ID Position: Before Bar

Strany 193 - By Autorun file

Label IDProduct Reference Guide 77Label ID — cont.START / ENDPROGRAMMING bar codesDEFAULT SETTING FOR THIS FEATURE: E (45 h

Strany 194

Data Editing78MagellanTM 3300HSiLabel ID — cont.START / ENDPROGRAMMING bar codesDEFAULT SETTING FOR THIS FEATURE: F (46 hex)Set EAN-13 w/P2 Addon Labe

Strany 195 - Appendix I

Label IDProduct Reference Guide 79Label ID — cont.START / ENDPROGRAMMING bar codesDEFAULT SETTING FOR THIS FEATURE: G8 (473

Strany 196

Data Editing80MagellanTM 3300HSiLabel ID — cont.START / ENDPROGRAMMING bar codesDEFAULT SETTING FOR THIS FEATURE: % (25 hex)Set Codabar Label ID Chara

Strany 197 - 189

Label IDProduct Reference Guide 81Label ID — cont.NOTEFor the 2D symbologies on this page, the Label ID is 4 bytes. The fi

Strany 198

Product Reference Guide1Chapter 1Getting StartedThe MagellanTM 3300HSi Horizontal Single Plane Scanner is designed for small counter retail checkout e

Strany 199 - 191

Data Editing82MagellanTM 3300HSiCase ConversionThis feature can convert scanned bar code data to either all lower case (a through z) or all upper case

Strany 200 - I 2 of 5

Character ConversionProduct Reference Guide 83Character ConversionCharacter conversion is an eight byte configuration item.

Strany 201

Data Editing84MagellanTM 3300HSiNOTES

Strany 202

Product Reference Guide85Chapter 6SymbologiesThe scanner supports the following symbologies (bar code types). Options for each symbology are included

Strany 203 - AIM Formats

Symbologies86MagellanTM 3300HSiUPC-A — continuedCheck Digit TransmissionEnable this option to transmit the check digit along with UPC-A bar code data.

Strany 204 - Bookland

UPC-AProduct Reference Guide 87UPC-A — continuedExpand UPC-A to EAN-13Expands UPC-A data to the EAN-13 data format. Selecti

Strany 205 - RSS Expanded

Symbologies88MagellanTM 3300HSiUPC-EThe following options apply to the UPC-E symbology.Disable/Enable UPC-EWhen disabled, the scanner will not read UP

Strany 206 - Code 128 / EAN128

UPC-EProduct Reference Guide 89UPC-E — continuedNumber System DigitThe Number System Digit (NSD) which is always a zero (0)

Strany 207 - ASCII Character Set

Symbologies90MagellanTM 3300HSiUPC-E — continuedExpand UPC-E to EAN13Enables/disables expansion of UPC-E labels to EAN-13. Selecting this feature also

Strany 208 - Datalogic ADC, Inc

UPC-EProduct Reference Guide 91GTINThe following options apply to the GTIN label data format.Expand UPC/EAN to GTINWhen thi

Komentáře k této Příručce

Žádné komentáře