Label ID
Product Reference Guide
153
Label ID
A Label ID is used to identify a bar code (symbology) type. See Appendix D, Factory Default Set-
tings
, for a listing for common symbologies. It can be appended previous to or following the
transmitted bar code data depending upon how this option is en
abled. This feature provides
options for configuring custom Label IDs individually per symbology. If you wish to program
the scanner to always include an industry standard label identifier for ALL symbology types, see
the feature,
AIM ID on page 75.
The Label ID is a customizable code of up to thr
ee ASCII characters (each of which are 00-FF)
followed by a control character (00-01), This control character, when set to zero, does nothing.
When set to one, it appends the symbology’s AIM ID to the Label ID.
NOTE
When the control character is set to 01 for UPC-A and UPC-E, it
expands the label to EAN-13 and thus follows the EAN-13 Label ID
settings.
To configure a Label ID:
1. Scan the START bar code.
2. Select Label ID position as either BEFORE
or AFTER by scanning the appropriate bar
code.
3. Scan a bar code to select the symbology for which you wish to configure a custom Label
ID.
4. Determine the desired character(s) (y
ou may choose up to three) which will represent the
Label ID for the selected symbology. Next, turn to the
ASCII Character Set on the inside
back cover of this manual and find the equivalent hex digits associated with your choice of
Label ID. F
or example, if you wish to select an equal sign (=) as a Label ID, the chart indi-
cates its associated hex characters as 3D.
5. Turn to
Appendix C, Alpha-Numeric Pad and scan the bar codes representing the hex char-
acters determined in the previous step. For example,
to make an equal sign (=), scan ‘3’
and ‘D’ followed by ‘0’ six times. Since this is a three-character buffer, ‘00’ is scanned for
character two, ‘00’ for character three and ‘00’ for the control character. (‘00’ indicates no
character.)
6. Scan the END bar code to exit programming mode.
Figure 2. Label ID Position
OR
Prefix SuffixLabel ID Label IDBar Code DataAim ID
Options