178 Appendix C: AccuLazr User Interface AccuLazr
AL5010 Product Line Manual
Modify Settings > Raster
NOTE: The Modify Settings > Raster selection is only
available on the menu tree when an AL5010 unit with the
raster option.
Selection Definition
Upper Sweep
Specify the upper limit of the laser from -20-degrees to +20
degrees from 0-degrees.
Lower Sweep
Specify the lower limit of the laser from -20-degrees to +20
egrees from 0-degrees. d
NOTE: The laser will sweep between the
specified upper and lower values.
Example 1: If the upper value is set at -5-
degrees and the lower value is set at -10-
degrees, the laser will sweep the 5-degree range
specified below 0-degrees.
Example 2: If both the upper and lower values
are set at the same value, the laser will stay on
that fixed value without sweeping.
Oscillating
Frequency (Hz)
Specify the frequency at which the vibrating vane (mirror) will
oscillate between 0 and 10 Hz. This is the speed of the mirror
oscillation with 0 being effectively stopped and 10 oscillating the
fastest.