Datalogic Dragon D131 Specifikace Strana 164

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 210
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 163
DRAGON™ D131/M131
154
2. the following example allows setting Special Key 2 (defined in example 2 above)
as header:
enter configuration
one character header special key 2 exit & save configuration
Read
Ì$+;Î
+
ÌEA01.Î
+
Ì9DÆÎ
+
Ì$-?Î
3. the following example allows setting Special Key 3 (defined in example 3 above)
as header:
enter configuration
one character header special key 3 exit & save configuration
Read
Ì$+;Î
+
ÌEA01.Î
+
Ì9EÈÎ
+
Ì$-?Î
4. the following example allows setting Special Key 4 (defined in example 4 above)
and ENTER character as terminators:
enter configuration
two character terminator special key 4
ASCII characters
corresponding to the
HEX value for character
ENTER
Read
Ì$+;Î
+
ÌEA125Î
+
Ì9FÊÎ
+
83
+
exit & save configuration
+
Ì$-?Î
5.4.3 Address Stamping
It is possible to include the reader address in the message sent to the host. The
Reader Address Stamping and the Cradle Address Stamping parameters consist of a
4-digit number in the range 0000 to 1999.
For message output format, refer to chapter 6.
5.4.4 Address Delimiter
The Address Delimiter allows a character to be included to separate the reader
Address stamping field from the next field in the message. Any character can be
included in the hexadecimal range from 00 to FE.
For message output format, refer to chapter 6.
Zobrazit stránku 163