DS2100
18
2
EXTERNAL TRIGGER
DS2100 25-pin
18
19
+ 5V
VS
9
25
GND
Ground
V
or
8
9
7
5
VS
GND
DS2100 9-pin
Signal
EXT TRIG+
EXT TRIG-
EXT TRIG+
EXT TRIG-
Figure 18 - Input PNP command using DS2100 power
Electrical features: Maximum voltage: 30 Vdc
Maximum current: 25 mA
An anti-disturbance hardware filter is implemented on the External Trigger input (< 5
milliseconds delay).
An additional 15 ms (typical) delay can be implemented through a dedicated software
parameter (refer to WinHost Help On Line).
2.3.5 Outputs
Two general purpose outputs are available which can be connected only in open
collector configurations. The outputs are available only on 25-pin connector models.
The following pins are present on the 25-pin connector of the scanner:
25-Pin Connector Name Function
8 OUT1+ output 1 +
11 OUT2+ output 2 +
12, 22 OUT REF output reference
The meaning of the two outputs OUT1 and OUT2 can be defined by the user (No
Read, Right or Wrong). Refer to the WinHost Help On Line.
By default, OUT1 is associated with the No Read event, which activates when the
code signaled by the external trigger is not decoded, and OUT2 is associated with
the Right event, which activates when the code is correctly decoded.
USER INTERFACE
Vext 40 Vdc max
+
8/11
12/22
OUT REF
DS2100 25-pin
Figure 19 - Output open collector connections
These outputs are both level or pulse configurable.