Datalogic QLM500 Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Čtečky čárových kódů Datalogic QLM500. Datalogic QLM500 Instruction manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 161
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - MATRIX 410™

MATRIX 410™Reference Manual

Strany 2

x GENERAL VIEW Matrix 410™ Figure A 1 2 3 4 9 8 7 Device Class Label Mounting Holes (12) Lens Cover Lens (separate ac

Strany 3 - CONTENTS

MATRIX 410™ REFERENCE MANUAL 90 5 INPUT 2 CONNECTIONS USING EXTERNAL POWER Matrix 410™ INPUT DEVICE Vext 30 Vdc max. D E VCC ~ ~ + - V Signal I2

Strany 4

MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 91 5 The output signals are fully programmable being determined by the configured Activation/

Strany 5

MATRIX 410™ REFERENCE MANUAL 92 5 5.10 USER INTERFACE RS232 PC-side connections 1 5 9 6 9-pin male connector 13 25 14 1 25-pin male connect

Strany 6 - REFERENCES

TYPICAL LAYOUTS 93 6 6 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. However, they also require the corr

Strany 7 - COMPLIANCE

MATRIX 410™ REFERENCE MANUAL 94 6 In this layout the data is transmitted to the Host on the TCP/IP Ethernet interface (CBX500 with BM200/210 Host I

Strany 8 - HANDLING

TYPICAL LAYOUTS 95 6 In this layout a single reader functions as a Slave node on a Fieldbus network. The data is transmitted to the Host through an

Strany 9

MATRIX 410™ REFERENCE MANUAL 96 6 6.2 PASS-THROUGH 6.2.1 Pass-Through on RS232 Pass-through mode allows two or more devices to be connected to

Strany 10 - GENERAL VIEW

TYPICAL LAYOUTS 97 6 6.2.2 Pass-Through on ID-NET™ An alternative Pass-Through layout allows the more efficient ID-NET™ network to be used. This l

Strany 11 - 1 RAPID CONFIGURATION

MATRIX 410™ REFERENCE MANUAL 98 6 6.3 ID-NET™ The ID-NET™ connection is used to collect data from several readers to build a multi-point or a mu

Strany 12 - Required Accessories

TYPICAL LAYOUTS 99 6 Figure 106 - ID-NET™ Synchronized Layout Matrix 410™ Master with CBX500 + Matrix 410™ Slaves with QL150 Figure 107

Strany 13 - STEP 2 – CONNECT THE SYSTEM

RAPID CONFIGURATION 1 1 1 RAPID CONFIGURATION STEP 1 – ASSEMBLE THE READER The first step to perform is to assemble the accessories that make up

Strany 14 - (polarity insensitive)

MATRIX 410™ REFERENCE MANUAL 100 6 The same configuration can be made to a Host using a TCP/IP Ethernet interface. In this case the Master is conne

Strany 15 - RAPID CONFIGURATION

TYPICAL LAYOUTS 101 6 For a Master/Slave Multidata layout each reader has its own reading phase independent from the others; each single message is

Strany 16 - STEP 4 – FOCUS THE READER

MATRIX 410™ REFERENCE MANUAL 102 6 The same configuration can be made to a Host using a TCP/IP Ethernet interface. In this case the Master is conne

Strany 17 - Locate Function

TYPICAL LAYOUTS 103 6 Alternatively, the Master reader can communicate to the Host as a Slave node on a Fieldbus network. This requires using an

Strany 18

MATRIX 410™ REFERENCE MANUAL 104 6 6.4 RS232 MASTER/SLAVE NOTE This interface is provided for backward compatibility. We recommend using the mor

Strany 19

TYPICAL LAYOUTS 105 6 6.5 MULTIPLEXER NOTE This interface is provided for backward compatibility. We recommend using the more efficient ID-NET™ n

Strany 20

MATRIX 410™ REFERENCE MANUAL 106 6 6.6 ETHERNET CONNECTION (Matrix 410 xxx-010 models only) For Matrix 410 xxx-010 models, the Ethernet connection

Strany 21

TYPICAL LAYOUTS 107 6 When using a Local Area Network (LAN), one or more Matrix 410 xxx-010s can be connected to the network by using

Strany 22

MATRIX 410™ REFERENCE MANUAL 108 7 7 READING FEATURES 7.1 OPTICAL ACCESSORY SELECTION Referring to Figure 117 and the formula below, use the d

Strany 23

READING FEATURES 109 7 Example: The FOV for a Matrix 410 600-0x0 base using the 16 mm lens at a focus distance of 200 mm is: FOVH = 2 [(200 mm +

Strany 24

MATRIX 410™ REFERENCE MANUAL 2 1 Required Accessories The following table shows the correct lens/illuminator combinations to be used for Matrix 4

Strany 25

MATRIX 410™ REFERENCE MANUAL 110 7 7.2.2 1D (Linear) Codes 1D Codes – Matrix 410 400-0x0 (SXGA) 9 mm, 12.5 mm, 16 mm 1D Codes - SXGA - 9mm, 12.5m

Strany 26

READING FEATURES 111 7 1D Codes – Matrix 410 600-0x0 (UXGA) 9 mm, 12.5 mm, 16 mm 1D Codes - UXGA - 9mm, 12.5mm, 16mm051015202530354045500 5 10 15 2

Strany 27 - STEP 9 – TEST MODE

MATRIX 410™ REFERENCE MANUAL 112 7 7.2.3 2D (Bi-dimensional) Codes 2D Codes – Matrix 410 400-0x0 (SXGA) 9 mm, 12.5 mm, 16 mm 2D Codes - SXGA - 9m

Strany 28

READING FEATURES 113 7 2D Codes – Matrix 410 600-0x0 (UXGA) 9 mm, 12.5 mm, 16 mm 2D Codes - UXGA - 9 mm, 12.5 mm, 16 mm05101520250 5 10 15 20 25 30

Strany 29

MATRIX 410™ REFERENCE MANUAL 114 7 7.3 MATRIX 410 655-0X0 READING FEATURES Focus Distance mm (in) Field of View (1) mm (in) PPI(2) Typical Linear

Strany 30 - Code Quality Verification

READING FEATURES 115 7 Example: A Matrix 410™ 600-010 using: Internal Lighting Mode = Very High Power Strobe Exposure Time (x10 s) = 10 (100 s)

Strany 31 - 2 INTRODUCTION

MATRIX 410™ REFERENCE MANUAL 116 7 Texp (min) is the minimum Exposure Time value obtainable for the specific application. It can be evaluated in st

Strany 32

SOFTWARE CONFIGURATION 117 8 8 SOFTWARE CONFIGURATION Software configuration of your Matrix 410™ for static reading or simple code re

Strany 33 - INTRODUCTION

MATRIX 410™ REFERENCE MANUAL 118 8 8.2 INSTALLING VISISET™ To install VisiSet™, proceed as follows: 1. Turn on the Laptop or PC that will be use

Strany 34

SOFTWARE CONFIGURATION 119 8 8.3.1 VisiSet™ Options The Options item from the VisiSet™ menu (see Figure 118) presents a window allowing you to con

Strany 35

RAPID CONFIGURATION 3 1 VisiSet™ Illuminator Management Procedure 1. Connect the reader to VisiSet™ as described in the Quick Reference Guide. 2.

Strany 36 - 2.3 ID-NET™

MATRIX 410™ REFERENCE MANUAL 120 8 Figure 121 - Options – Communication: Serial Port Figure 122 - Options – Communication: Ethernet

Strany 37

SOFTWARE CONFIGURATION 121 8 8.4 CONFIGURATION Once connected to Matrix 410™ as described in par. 8.3, you can modify the configuration parameters

Strany 38

MATRIX 410™ REFERENCE MANUAL 122 8 8.4.1 Edit Reader Parameters The Parameter Setup window displays the configuration parameters grouped in a ser

Strany 39

SOFTWARE CONFIGURATION 123 8Parameters to verify/modify:  Operating Mode Sets the parameters which customize the reader operating mode starting fro

Strany 40 - VISISET™

MATRIX 410™ REFERENCE MANUAL 124 8 When all the configuration parameters are set correctly, save them to the Matrix 410™ reader by pre

Strany 41 - Restore

SOFTWARE CONFIGURATION 125 8 Environmental Parameters regard the device Identity and Position in a Network (ID-NET™, Master/Slave RS232, MUX 32,

Strany 42 - Replacement

MATRIX 410™ REFERENCE MANUAL 126 8 HOST INTERFACE - Host Interface Type CBX ETHERNET SYSTEM (CBX with Host Interface Modules) - Status - DHCP Clie

Strany 43

SOFTWARE CONFIGURATION 127 8 For device replacement it is necessary to send the previously saved configuration (both Configuration and E

Strany 44

MATRIX 410™ REFERENCE MANUAL 128 8 8.4.3 Calibration VisiSet™ provides a Calibration Tool to maximize the reading performance by tuning the

Strany 45 - 2.5.1 X-PRESS™ Functions

SOFTWARE CONFIGURATION 129 8 The Parameter Setup window works in Interactive Mode in order to cause each parameter setting to be immediately effecti

Strany 46 - Focus/Locate (Function 2)

MATRIX 410™ REFERENCE MANUAL 4 1 CBX100/CBX500 Pinout for Matrix 410™ The table below gives the pinout of the CBX100/CBX500 terminal block connect

Strany 47 - 2.5.2 Diagnostic Indication

MATRIX 410™ REFERENCE MANUAL 130 8 Over-exposure: To correct this result it is recommended to change the following parameters in their order of app

Strany 48 - 2.7 ACCESSORIES

SOFTWARE CONFIGURATION 131 8 Moving code out of the Field of View: To correct this result and have the code completely visible in F.O.V., it is poss

Strany 49

MATRIX 410™ REFERENCE MANUAL 132 8 8.4.4 Multi Image Acquisition Settings When controlled variable conditions occur in the application, Mu

Strany 50 - 2.7.1 Lighting System Notes

SOFTWARE CONFIGURATION 133 8 8.4.6 Region Of Interest Windowing In order to satisfy very high throughput applications, higher frame rates can be a

Strany 51 - 2.8.1 Document Handling

MATRIX 410™ REFERENCE MANUAL 134 8 8.4.7 Direct Part Marking Applications Decoding Method: Direct Marking For Data Matrix and QR code the

Strany 52

SOFTWARE CONFIGURATION 135 8 Image Filter Sets the filter to be applied to the image before being processed. This parameter can be used to successf

Strany 53 - 2.8.4 Direct Part Marking

MATRIX 410™ REFERENCE MANUAL 136 8 The Open filter eliminates white areas (defects) in the dark zones of the image. Before - No Read After - Re

Strany 54

SOFTWARE CONFIGURATION 137 8 The Histogram Equalization filter makes the gray level distribution uniform. Before - No Read After - Readable Hist

Strany 55

MATRIX 410™ REFERENCE MANUAL 138 8 The Deblurring filter improves blurred images. Before - No Read After - Readable Deblurring The Black

Strany 56

SOFTWARE CONFIGURATION 139 8 8.5 IMAGE CAPTURE AND DECODING By using the Capture Image and Decode Last Image functions from the VisiSet™ Mai

Strany 57 - 3 INSTALLATION

RAPID CONFIGURATION 5 1 STEP 3 – MOUNT AND POSITION THE READER 1. To mount the Matrix 410™, use the mounting brackets to obtain the mo

Strany 58 - 3.2 MECHANICAL DIMENSIONS

MATRIX 410™ REFERENCE MANUAL 140 9 9 MAINTENANCE 9.1 CLEANING Clean the reading window (see Figure A, 1) periodically for continued correct op

Strany 59 - INSTALLATION

TROUBLESHOOTING 141 10 10 TROUBLESHOOTING 10.1 GENERAL GUIDELINES When wiring the device, pay careful attention to the signal name

Strany 60 - [Ø0.32]

MATRIX 410™ REFERENCE MANUAL 142 10 TROUBLESHOOTING GUIDE Problem Suggestion One Shot or Phase Mode using serial trigger source: the ”TRIGGER”

Strany 61

TROUBLESHOOTING 143 10 TROUBLESHOOTING GUIDE Problem Suggestion Communication: data transferred to the host are incorrect, corrupted or inco

Strany 62 - Figure 45 - Tilt angle

MATRIX 410™ REFERENCE MANUAL 144 11 11 TECHNICAL FEATURES ELECTRICAL FEATURES Power all models except 655-0x0 655-0x0 models Supply Voltage 10 to

Strany 63 - CBX ELECTRICAL CONNECTIONS

TECHNICAL FEATURES 145 11 SOFTWARE FEATURES Readable Code Symbologies 1-D and stacked 2-D POSTAL PDF417 Standard and Micro PDF417 Code 128 (GS

Strany 64 - 4.1 POWER SUPPLY

146 GLOSSARY AIM (Association for Automatic Identification and Mobility): AIM Global is the international trade association representing automati

Strany 65 - 4.2 MAIN SERIAL INTERFACE

147 Depth of Field The difference between the minimum and the maximum distance of the object in the field of view that appears to be in focus. Dif

Strany 66 - 4.2.1 RS232 Interface

148 ISO (International Organization for Standardization): A network of the national standards institutes of several countries producing wo

Strany 67

149 INDEX A Accessories, 38 Application Examples, 41 Auxiliary RS232 Interface, 65, 85 C Calibration, 128 CBX Electrical Connections, 53 Complian

Strany 68

MATRIX 410™ REFERENCE MANUAL 6 1 3. Refer to the Reading Features table in chp. 7 for FOV calculation and minimum distance requireme

Strany 69

DECLARATION OF CONFORMITY EC-124 Rev.: 4 Pag.: 1 di 1 Datalogic Automation S.r.l. Via Lavino 2

Strany 71 - 4.3.2 ID-NET™ Response Time

RAPID CONFIGURATION 7 1 NOTE If necessary you can use the Fine Focusing Tool in the VisiSet™ Setup Wizard for fine focusing. See Step 8

Strany 72

MATRIX 410™ REFERENCE MANUAL 8 1 Setup 5. Enter the Setup function by pressing and holding the X-PRESS™ push button until the Setup LED is on. 6.

Strany 73

RAPID CONFIGURATION 9 1 STEP 6 – X-PRESS™ CONFIGURATION Once Matrix 410™ has calibrated image density, you can configure it for optimal

Strany 74

Datalogic Automation S.r.l. Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy Matrix 410™ Reference Manual Ed.: 03/2014

Strany 75

MATRIX 410™ REFERENCE MANUAL 10 1 Learn 8. Enter the Learn function by pressing and holding the X-PRESS™ push button until the Learn LED is on. 9.

Strany 76 - 4.5 INPUTS

RAPID CONFIGURATION 11 1 STEP 7 – INSTALLING VISISET™ CONFIGURATION PROGRAM VisiSet™ is a Datalogic reader configuration tool providing several imp

Strany 77

MATRIX 410™ REFERENCE MANUAL 12 1 CAUTION In order for VisiSet™ to correctly manage the illuminator parameters, in the VisiSet™ Tools menu click t

Strany 78

RAPID CONFIGURATION 13 1 3. Press the "Positioning" button. The reader continuously acquires images and gives visual feedback in the v

Strany 79

MATRIX 410™ REFERENCE MANUAL 14 1 5. Press the "Fine Focusing" button to activate the Fine Focusing Tool. The reader continuously acq

Strany 80

RAPID CONFIGURATION 15 1 Tighten the Locking Knobs on the lens and press the "Close" button to return to the Setup Wizard. 6. Select a

Strany 81

MATRIX 410™ REFERENCE MANUAL 16 1 8. Select a Saving Options choice and press the "Save" button. 9. Close the Setup Wizard.

Strany 82

RAPID CONFIGURATION 17 1 STEP 9 – TEST MODE Use a code suitable to your application to test the reading performance of the system. 1. Enter the T

Strany 83 - 5.1 M16 19-PIN CONNECTOR

MATRIX 410™ REFERENCE MANUAL 18 1 FOCUSING MATRIX 410 655-0X0 MODELS (OPTIONAL) Matrix 410 655-0x0 models are pre-assembled at the factory

Strany 84

RAPID CONFIGURATION 19 1 Figure 18 – Focus Function Using Blue Diamonds™ 7. Exit the Focus function by pressing the X-PRESS™ push button

Strany 85

iii CONTENTS REFERENCES ... vi Convention

Strany 86 - 5.4.1 RS232 Interface

MATRIX 410™ REFERENCE MANUAL 20 1 ADVANCED READER CONFIGURATION For further details on advanced product configuration, refer to the VisiSet™ Help

Strany 87

INTRODUCTION 21 2 2 INTRODUCTION 2.1 PRODUCT DESCRIPTION Matrix 410™ is a Datalogic industrial compact 2D imager designed and produc

Strany 88

MATRIX 410™ REFERENCE MANUAL 22 2 Standard Application Program A Standard Application Program is factory-loaded onto Matrix 410™. This program cont

Strany 89

INTRODUCTION 23 2 Ease of Setup Quick installation without PC by using X-PRESS™ interface for easy and intuitive setup Blue Diamonds™ aiming and

Strany 90 - 5.5.1 ID-NET™ Cables

MATRIX 410™ REFERENCE MANUAL 24 2 Industrial Strength Industrial compact 2D reader Rugged full metal construction Sealed circular connectors

Strany 91 - 5.5.2 ID-NET™ Response Time

INTRODUCTION 25 2 2.2 INDICATORS AND KEYPAD BUTTON Figure 20 - Indicators The following LED indicators are located on the reader: NET yellow L

Strany 92

MATRIX 410™ REFERENCE MANUAL 26 2 2.3 ID-NET™ The ID-NET™ network is a built-in high-speed interface dedicated for high-speed reader interconnec

Strany 93

INTRODUCTION 27 2  ID-NET™ M/S Multidata: Multiple stations – single reader ID-NET™ interface allows connection of readers reading objec

Strany 94

MATRIX 410™ REFERENCE MANUAL 28 2 7. Configure the other device parameters via VisiSet™ [Operating Mode, Calibration, Data Collection parameters,

Strany 95

INTRODUCTION 29 2 2.3.2 ID-NET™ Slave Management Through Master When an ID-NET™ layout has already been configured, it is possible to

Strany 96

iv 3 INSTALLATION ... 47 3.1 Package Conten

Strany 97 - 5.8 INPUTS

MATRIX 410™ REFERENCE MANUAL 30 2 2.4 EXTERNAL MEMORY BACKUP AND RESTORE THROUGH VISISET™ The "External Memory Backup" or "E

Strany 98 - Matrix 410™

INTRODUCTION 31 2 The VisiSet™ Main window shows information as the backup procedure is performed and a message indicating successful completion.

Strany 99 - INPUT DEVICE

MATRIX 410™ REFERENCE MANUAL 32 2 The VisiSet™ Main window shows information as the restore procedure is performed and a message indicating success

Strany 100 - 5.9 OUTPUTS

INTRODUCTION 33 2 Erase To Erase any previous Backup: 1. Select "External Memory Erase" from the VisiSet™ Device menu 2. You will be w

Strany 101 - USER INTERFACE

MATRIX 410™ REFERENCE MANUAL 34 2 List To see a List of the current Backup: 1. Select "External Memory Read Backup" from the VisiSet™

Strany 102 - MATRIX 410™ REFERENCE MANUAL

INTRODUCTION 35 2 2.5 X-PRESS™ HUMAN MACHINE INTERFACE X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of in

Strany 103 - 6 TYPICAL LAYOUTS

MATRIX 410™ REFERENCE MANUAL 36 2 READY green green yellow yellow red SETUP FOCUS TEST LEARN GOOD TRIGGER COM STATUS READY green green yellow ye

Strany 104

INTRODUCTION 37 2 Setup (Function 3) Once entered, the imager automatically performs Image Acquisition parameter calibration for the specific code

Strany 105

MATRIX 410™ REFERENCE MANUAL 38 2 2.6 MODEL DESCRIPTION The Matrix 410™ reader is available in different basic versions according to

Strany 106 - 6.2.1 Pass-Through on RS232

INTRODUCTION 39 2 Accessory Description Order No. CBL-1480-02 Thin M12/5P Male/Female (2M) 93A050050 CBL-1490 Term. Resist. Thin M12/5P/Male 93A050

Strany 107

v 7.2.2 1D (Linear) Codes ... 110 7.2.3 2D (Bi-d

Strany 108 - 6.3 ID-NET™

MATRIX 410™ REFERENCE MANUAL 40 2 2.7.1 Lighting System Notes The following table shows the correct lens/illuminator combinations to be used for

Strany 109 -  BA300 Service

INTRODUCTION 41 2 VisiSet™ Illuminator Management Procedure 1. Connect the reader to VisiSet™ as described in the Quick Reference Guide. 2. In th

Strany 110

MATRIX 410™ REFERENCE MANUAL 42 2 2.8.3 Deformed or Overprinted Code Reading Matrix 410™ assures the reading of deformed and / or overp

Strany 111

INTRODUCTION 43 2 2.8.4 Direct Part Marking Matrix 410™ is also very powerful in reading low-contrast direct part marked codes (see Figures 25, 26

Strany 112

MATRIX 410™ REFERENCE MANUAL 44 2 2.8.6 Laser Marking/Etching Technology Figure 30 - Data Matrix Code Directly Marked on PCB Surface by Using La

Strany 113 - Fieldbus Interface

INTRODUCTION 45 2 2.9 EXTERNAL LIGHTING SYSTEMS In some direct part marking applications best reading results are obtained by using a

Strany 114 - 6.4 RS232 MASTER/SLAVE

MATRIX 410™ REFERENCE MANUAL 46 2 The LT-630 Four Bar Lighting System is designed for Code verification applications according to ISO/IE

Strany 115 - 6.5 MULTIPLEXER

INSTALLATION 47 3 3 INSTALLATION 3.1 PACKAGE CONTENTS Verify that the Matrix 410™ reader and all the parts supplied with the equipment are pres

Strany 116 - 6.6 ETHERNET CONNECTION

MATRIX 410™ REFERENCE MANUAL 48 3 3.2 MECHANICAL DIMENSIONS Matrix 410™ can be installed to operate in different positions. The twelve screw hole

Strany 117 - TYPICAL LAYOUTS

INSTALLATION 49 3 60.5[2.38]30.3 [1.19]143 [5.62]109 [4.29]123.2[4.85]Ø100 [Ø3.94]87[3.41]41.5[1.63]18[0.71]8° Figure 38 - Matrix 410 655-0x0 Model

Strany 118 - 7 READING FEATURES

vi REFERENCES CONVENTIONS This manual uses the following conventions: "User" refers to anyone using a Matrix 410™ reader. "Reade

Strany 119 - READING FEATURES

MATRIX 410™ REFERENCE MANUAL 50 3 4 [0.16]M4 [0.16] N°77 [0.28]12.5 [0.49]12.5 [0.49]4.3 [0.17]4.3 [0.17]50 [1.97]61 [2.40]==72.5 [2.85]83.5 [3.29

Strany 120 - 7.2.2 1D (Linear) Codes

INSTALLATION 51 3 3.3 MOUNTING AND POSITIONING MATRIX 410™ Using the Matrix 410™ mounting brackets you can obtain rotation on the various axes of

Strany 121

MATRIX 410™ REFERENCE MANUAL 52 3 Matrix 410™ is able to decode code labels at a variety of angles, however significant angular distortion may degr

Strany 122

CBX ELECTRICAL CONNECTIONS 53 4 4 CBX ELECTRICAL CONNECTIONS All Matrix 410™ models can be connected to a CBX connection box through

Strany 123

MATRIX 410™ REFERENCE MANUAL 54 4 NOTE To avoid electromagnetic interference when the reader is connected to a CBX connection box, verify the jump

Strany 124

CBX ELECTRICAL CONNECTIONS 55 4 4.1.1 Ultra High Power Illuminator Models Matrix 410 655-0x0 models require 24 Vdc. Power must be supplied to both

Strany 125 - Line Speed

MATRIX 410™ REFERENCE MANUAL 56 4 4.2.1 RS232 Interface The RS232 interface can be used for Point-to-Point, Pass Through or Master/Sla

Strany 126

CBX ELECTRICAL CONNECTIONS 57 4 4.2.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled co

Strany 127 - 8 SOFTWARE CONFIGURATION

MATRIX 410™ REFERENCE MANUAL 58 4 4.2.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend usi

Strany 128 - 8.3 STARTUP

CBX ELECTRICAL CONNECTIONS 59 4 Figure 53 - Matrix 410™ Multidrop Connection to a Multiplexer * When using CBX500, the Main interface multi

Strany 129 - 8.3.1 VisiSet™ Options

vii COMPLIANCE For installation, use and maintenance it is not necessary to open the reader. Only connect Ethernet and dataport connections to a

Strany 130

MATRIX 410™ REFERENCE MANUAL 60 4 4.3 ID-NET™ INTERFACE CBX100/500 Function Shield Network Cable Shield ID+ ID-NET™ network + ID- ID-NET™ network

Strany 131 - 8.4 CONFIGURATION

CBX ELECTRICAL CONNECTIONS 61 4 4.3.2 ID-NET™ Response Time The following figure shows the response time of the ID-NET™ network. This time is def

Strany 132

MATRIX 410™ REFERENCE MANUAL 62 4 Figure 55 – ID-NET™ Network Connections with isolated power blocks

Strany 133 - Parameters to verify/modify:

CBX ELECTRICAL CONNECTIONS 63 4 Figure 56 - ID-NET™ Network Connections with Common Power Branch Network

Strany 134

MATRIX 410™ REFERENCE MANUAL 64 4 Figure 57 – ID-NET™ Network Connections with Common Power Star Network

Strany 135 - SOFTWARE CONFIGURATION

CBX ELECTRICAL CONNECTIONS 65 4 4.3.3 ID-NET™ Network Termination The network must be properly terminated in the first and last reader of the netw

Strany 136

MATRIX 410™ REFERENCE MANUAL 66 4 4.5 INPUTS There are two optocoupled polarity insensitive inputs available on the reader: Input 1 (

Strany 137

CBX ELECTRICAL CONNECTIONS 67 4 EXTERNAL TRIGGER INPUT CONNECTIONS USING MATRIX 410™ POWER CAUTION Power is available directly to the Input

Strany 138 - 8.4.3 Calibration

MATRIX 410™ REFERENCE MANUAL 68 4 CBX100/500 Function +V Power Source - Inputs I2A Input 2 A (polarity insensitive) I2B Input 2 B (polarity insens

Strany 139

CBX ELECTRICAL CONNECTIONS 69 4 Pulled up to External Input Device Power Input Signal Input Device Figure 65 - NPN Input 2 Using External Power

Strany 140

viii HANDLING The Matrix 410™ is designed to be used in an industrial environment and is built to withstand vibration and shock when correctl

Strany 141

MATRIX 410™ REFERENCE MANUAL 70 4 OUTPUT CONNECTIONS USING MATRIX 410™ POWER CAUTION Power is available directly to the Output Device, indepen

Strany 142

CBX ELECTRICAL CONNECTIONS 71 4 4.7 EXTERNAL LIGHTING SYSTEMS If an External Illuminator is used, it can be powered from the CBX connection box. I

Strany 143

MATRIX 410™ REFERENCE MANUAL 72 4 4.8 USER INTERFACE - HOST The following table contains the pinout for standard RS232 PC Host interface. For oth

Strany 144

MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 73 5 5 MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 5.1 M16 19-PIN CONNECTOR The Matrix 410™ re

Strany 145

MATRIX 410™ REFERENCE MANUAL 74 5 5.2 M12-D 4-PIN CONNECTOR (ETHERNET) In Matrix 410 xxx-x1x models, an M12 D-Coded connector is provid

Strany 146

MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 75 5 5.3.1 Ultra High Power Illuminator Models Matrix 410 655-0x0 models require 24 Vdc. Power must b

Strany 147

MATRIX 410™ REFERENCE MANUAL 76 5 5.4.1 RS232 Interface The RS232 interface can be used for Point-to-Point, Pass Through or Master/Sla

Strany 148

MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 77 5 5.4.2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used

Strany 149 - 8.6 STATISTICS

MATRIX 410™ REFERENCE MANUAL 78 5 5.4.3 RS485 Half-Duplex Interface NOTE This interface is provided for backward compatibility. We recommend usi

Strany 150 - 9 MAINTENANCE

MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 79 5 The figure below shows a multidrop configuration with Matrix 410™ readers connected to a Multiplex

Strany 151 - 10 TROUBLESHOOTING

ix do not weld the reader into position which can cause electrostatic, heat or reading window damage. do not spray paint near the reader w

Strany 152

MATRIX 410™ REFERENCE MANUAL 80 5 5.5 ID-NET™ INTERFACE Pin Name Function R ID+ ID-NET™ network + P ID- ID-NET™ network - L GND Ground 5.5.1 I

Strany 153

MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 81 5 5.5.2 ID-NET™ Response Time The following figure shows the response time of the ID-NET™ network

Strany 154 - 11 TECHNICAL FEATURES

MATRIX 410™ REFERENCE MANUAL 82 5 Figure 82 – ID-NET™ Network Connections with isolated power blocks

Strany 155 - TECHNICAL FEATURES

MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 83 5 Figure 83 - ID-NET™ Network Connections with Common Power Branch Network

Strany 156 - GLOSSARY

MATRIX 410™ REFERENCE MANUAL 84 5 Figure 84 – ID-NET™ Network Connections with Common Power Star Network

Strany 157

MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 85 5 5.5.3 ID-NET™ Network Termination The network must be properly terminated by a 120 Ohm resistor

Strany 158

MATRIX 410™ REFERENCE MANUAL 86 5 5.7 ETHERNET INTERFACE (MATRIX 410 XXX-010 MODELS ONLY) The Ethernet Interface can be used for TCP/IP communica

Strany 159

MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 87 5 5.8 INPUTS There are two optocoupled polarity insensitive inputs available on the M16 19-pin con

Strany 160 - UNI EN ISO 14001

MATRIX 410™ REFERENCE MANUAL 88 5 EXTERNAL TRIGGER INPUT PNP PH-1 Vdc GND I1A I1B PNP PH-1 wires Matrix 410™ B C L (brown) +10-30 Vdc (black) NO

Strany 161

MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 89 5 Matrix 410™ EXTERNAL TRIGGER Vext 30 Vdc max. A B Signal V VCC ~ ~ + - I1A I1B Figure 91 - Exte

Komentáře k této Příručce