ALTERNATIVE LAYOUTS
117
A
PASS THROUGH
When Pass Through is activated on the Auxiliary interface, the DS8100A reader can be
integrated in a network consisting of different scanners not provided with a Lonworks
interface.
This connection mode allows two or more devices to be connected to a single external serial
interface. The DS8100A transmits the messages received by its auxiliary interface onto its
main interface. The received data is transmitted "as is", (passed-through), and therefore any
data formatting requirements must be made at each individual reader.
In this configuration a series of scanners can be connected together using RS232 on the
main interface and all messages will be passed through this chain to the host. The reading
phase of each scanner is independent from the others. In Pass Through connections each
scanner is provided with its relative External Trigger (multi P.S.).
Applications can be implemented to connect a device such as a hand-held reader to the
Auxiliary port for manual code reading capability.
For the RS232 connections the maximum cable length is 15 m (50 ft).
The scanners represented in the following figures are configured in Pass Through mode.
1
2
Main Serial Interface
A
uxiliary Serial Interface
* P.S. (Presence Sensor) connected to Input 1 (External Trigger/PS) input.
Figure 106 – Pass Through Connection for DS8100A Standard Models
P.S.* P.S.* P.S.*
DS8100A
Power
CBX100
DS2100N
Gryphon
Host
CBX100
CBX100
DS2100N
1 21
2
CAB-F0x
2
1
Zobrazit stránku 130