DS8100A REFERENCE MANUAL
78
8
Parameter
Default Setting
Main Serial Port Parameters
Main Port Communication Mode Standard
Main Port Electrical Interface RS232
Handshake None
Baud Rate 9600
Parity None
Data Bits 8
Stop Bits 1
Auxiliary Serial Port
Search for CBX BM100 at Device Startup Enabled (checked)
Data Tx Enabled (checked)
Heartbeat Disable
Pass Through Disabled (unchecked)
Auxiliary Serial Port Parameters
Baud Rate 115200
Parity None
Data Bits 8
Stop Bits 1
Digital I/O Setting
Digital Input Lines Setting
Debouncing For Input 1, 3 and 4 5ms
Debouncing For Input 2 500 µs
Input 1 Active Level Overridden by Op. Mode Active Closed
Input 2 Active Level Overridden by Op. Mode Active Closed
Input 3 Active Level Overridden by Op. Mode Active Closed
Input 4 Active Level Overridden by Op. Mode Active Closed
Output 1
Line State Normally Open
Activation Event Complete Read
Alternative Activation Event Wrong
Deactivation Event Timeout
Alternative Deactivation Event None
Activate on any Diagnostic Error Disabled (unchecked)
Deactivate when all Diagnostic Errors
Recovered
Disabled (unchecked)
Deactivation Timeout (ms) 50
Output 2
Line State Normally Open
Activation Event No Read
Alternative Activation Event Partial Read
Deactivation Event Timeout
Alternative Deactivation Event None
Activate on any Diagnostic Error Disabled (unchecked)
Deactivate when all Diagnostic Errors
Recovered
Disabled (unchecked)
Deactivation Timeout (ms) 50