INSTALLATION
39
2
2.5.6 Fieldbus Network
The Fieldbus models offer connectivity without any converter or adapter needed.
The DX8200A master Fieldbus communicates with a remote host (for ex. remote PC
connected via Internet) by means of a cable connected to the Fieldbus connector provided. It
can be activated by a signal generated by the remote Host or by a physical presence sensor.
The external signals (trigger, encoder) are connected to the master through the C-BOX 100.
The system is powered by the PWR-240 where:
the master is connected through CAB-860X, which also provides bus termination
the last slave is connected through CAB-830X, which also provides bus return.
the master and all slaves are connected together through the CAB-810X cables
The same network layouts are available as for the DX8200A standard model.
CAB810X
CAB810X
PWR-240
Slave 3
Slave 4
CAB830X
CAB860X
C-BOX 100**
CAB601X
P.S.*
CAB810X
CAB810X
Encoder***
Fieldbus
Network
Maste
r
Slave 2 Slave 1
Remote Host
* P.S. (Presence Sensor) connected to External Trigger/PS input.
** C-BOX 100 modified to accept scanner power.
*** Encoder connected to IN2/ENC input.
Figure 44 – Fieldbus Small Synchronized Network