Strany 1 - Magellan

MagellanTM 1100iOn-Counter Presentation Omnidirectional Bar Code ReaderProduct Reference Guide

Strany 2

Getting Started2MagellanTM 1100iConnecting the ScannerThe scanner kit you ordered to match your interface should provide a compatible cable for your i

Strany 3 - Table of Contents

Symbologies92MagellanTM 1100iPrice Weight Check DigitEnables/disables calculation and verification of price/weight check digits.NOTEApplies to all UPC

Strany 4

Add-onsProduct Reference Guide 93Add-onsAdd-ons (or supplemental characters) are commonly added to the end of UPC/EAN barco

Strany 5 - Product Reference Guide iii

Symbologies94MagellanTM 1100iAdd-ons — continuedSTART / ENDPROGRAMMING BARCODESDisable Optional 2-Digit Add-onsDEFAULTEnable Optional 2-Digit Add-onsD

Strany 6

Add-onsProduct Reference Guide 95Add-ons — continued2-Digit Addons Minimum ReadsThis setting configures the minimum number

Strany 7

Symbologies96MagellanTM 1100iAdd-ons — continued5-Digit Addons Minimum ReadsThis setting configures the minimum number of times a 5-digit addon must d

Strany 8

GS1 DataBar Omnidirectional / Stacked OmnidirectionalProduct Reference Guide 97GS1 DataBar Omnidirectional / Stacked Omnidi

Strany 9 - Getting Started

Symbologies98MagellanTM 1100iGS1 DataBar Omnidirectional / Stacked Omnidirectional — continuedMinimum ReadsThis feature specifies the minimum number o

Strany 10 - Connecting the Scanner

GS1 DataBar Expanded / Expanded StackedProduct Reference Guide 99GS1 DataBar Expanded / Expanded StackedThe following optio

Strany 11 - Programming

Symbologies100MagellanTM 1100iGS1 DataBar Expanded / Expanded Stacked — continuedLength ControlFixed Length Decoding— When fixed length decoding is en

Strany 12 - LED and Beeper Indicators

GS1 DataBar Expanded / Expanded StackedProduct Reference Guide 101GS1 DataBar Expanded / Expanded Stacked — continuedGS1 Da

Strany 13 - Error Codes

ProgrammingProduct Reference Guide 3IBM Connection — Connect the scanner to the IBM port on the terminal/PC using the cor-r

Strany 14

Symbologies102MagellanTM 1100iGS1 DataBar Expanded / Expanded Stacked — continuedMinimum ReadsThis feature specifies the minimum number of consecutive

Strany 15 - General Features

GS1 DataBar Expanded / Expanded StackedProduct Reference Guide 103GS1 DataBar Expanded / Expanded Stacked — continuedCoupon

Strany 16

Symbologies104MagellanTM 1100iGS1 DataBar LimitedThe following options apply to the GS1 DataBar Limited symbology.Disable/Enable GS1 DataBar LimitedWh

Strany 17 - Aztec or Composite label

GS1 DataBar LimitedProduct Reference Guide 105GS1 DataBar Limited — continuedMinimum ReadsThis feature specifies the minimu

Strany 18 - Label Gone Timeout

Symbologies106MagellanTM 1100iCode 39The following options apply to the Code 39 symbology.Disable/Enable Code 39When this feature is disabled, the sca

Strany 19 - Sleep Mode

Code 39Product Reference Guide 107Check Character TransmitEnable this option to transmit the check character with scanned b

Strany 20 - Sleep Mode — cont

Symbologies108MagellanTM 1100iCode 39 Full ASCIIEnables/disables the translation of Code 39 characters to Code 39 full-ASCII charactersSTART / ENDPROG

Strany 21

Code 39Product Reference Guide 109Code 39 — continuedLength ControlFixed Length Decoding— When fixed length decoding is ena

Strany 22 - ERI Timeout

Symbologies110MagellanTM 1100iCode 39 Length 1, Length 2 Programming Instructions1. Scan the START/END barcode.2. Scan either the Set Length 1 or Set

Strany 23 - Good Read: When to Indicate

Code 39Product Reference Guide 111Code 39 — continuedCode 39 StitchingEnables/disables stitching for Code 39 labels. When p

Strany 24 - Good Read Beep Frequency

Getting Started4MagellanTM 1100iLED and Beeper IndicatorsThe scanner’s beeper sounds and its green LED illuminates to indicate various functions or er

Strany 25 - Good Read Beep Length

Symbologies112MagellanTM 1100iCode 32 Italian PharmacodeThe following options apply to the Code 32 Italian Pharmacode symbology.Disable/Enable Code 32

Strany 26 - Green Spot

Code 32 Italian PharmacodeProduct Reference Guide 113Code 32 Italian Pharmacode — continuedCheck Character TransmitEnable t

Strany 27 - Aiming Pointer Settings

Symbologies114MagellanTM 1100iCode 128The following options apply to the Code 128 symbology.Disable/Enable Code 128When this feature is disabled, the

Strany 28 - Scanning Features

Code 128Product Reference Guide 115Code 128 — continuedTransmit Function CharactersEnables/disables transmission of Code128

Strany 29 - Target Mode Linger Time

Symbologies116MagellanTM 1100iCode 128 — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will decode

Strany 30 - Wake Up Intensity

Code 128Product Reference Guide 117Code 128 — continuedCode 128 Length 1, Length 2 Programming Instructions1. Scan the STAR

Strany 31 - Image Capture

Symbologies118MagellanTM 1100iCode 128 — continuedCode 128 StitchingEnables/disables stitching for Code 128 labels. When parts of a Code 128 barcode a

Strany 32 - Image Size

Interleaved 2 of 5Product Reference Guide 119Interleaved 2 of 5The following options apply to the Interleaved 2 of 5 (I 2 o

Strany 33 - Image Contrast

Symbologies120MagellanTM 1100iInterleaved 2 of 5 — continuedCheck Digit TransmitEnable this option to transmit the check digit with scanned barcode da

Strany 34 - Cell Phone Mode

Interleaved 2 of 5Product Reference Guide 121Interleaved 2 of 5 — continuedLength ControlFixed Length Decoding— When fixed

Strany 35

Error CodesProduct Reference Guide 5Error CodesUpon startup, if the scanner flashes its indicator LED or sounds an unexpect

Strany 36

Symbologies122MagellanTM 1100iInterleaved 2 of 5 — continuedInterleaved 2 of 5 Length 1, Length 2 Programming Instructions1. Scan the START barcode.2.

Strany 37 - Cell Phone in Target Mode

Interleaved 2 of 5Product Reference Guide 123Interleaved 2 of 5 — continuedInterleaved 2 of 5 StitchingEnables/disables sti

Strany 38

Symbologies124MagellanTM 1100iInterleaved 2 of 5 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Interleaved

Strany 39 - Interface Related Features

CodabarProduct Reference Guide 125CodabarThe following options apply to the Codabar symbology.Disable/Enable CodabarWhen th

Strany 40 - Mappings

Symbologies126MagellanTM 1100iCheck Character TransmitEnable this option to transmit the check character with scanned barcode data.START / ENDPROGRAMM

Strany 41 - Interface Selection

CodabarProduct Reference Guide 127Codabar — continuedLength ControlFixed Length Decoding— When fixed length decoding is ena

Strany 42 - Interface Selection — cont

Symbologies128MagellanTM 1100iCodabar — continuedCodabar Length 1, Length 2 Programming Instructions1. Scan the START barcode.2. Scan either the Set L

Strany 43 - Interface Features

CodabarProduct Reference Guide 129Codabar — continuedStart/Stop Character TypeCodabar has four pairs of Start/Stop patterns

Strany 44 - Interface Features — cont

Symbologies130MagellanTM 1100iStart/Stop Character MatchThis feature enables/disables the requirement that start and stop characters match.START / END

Strany 45 - RS-232 Interface Features

CodabarProduct Reference Guide 131Codabar — continuedMinimum ReadsThis feature specifies the minimum number of consecutive

Strany 46

Getting Started6MagellanTM 1100iNOTES

Strany 47 - Hardware Flow Control

Symbologies132MagellanTM 1100iCode 93The following options apply to the Code 93 symbology.Disable/Enable Code 93When this feature is disabled, the sca

Strany 48 - Intercharacter Delay

Code 93Product Reference Guide 133Code 93 — continuedLength ControlFixed Length Decoding— When fixed length decoding is ena

Strany 49 - Software Flow Control

Symbologies134MagellanTM 1100iCode 93 — continuedCode 93 Length 1, Length 2 Programming Instructions1. Scan the START barcode.2. Scan either the Set L

Strany 50 - Host Echo Quiet Interval

Code 93Product Reference Guide 135Code 93 — continuedCode 93 StitchingEnables/disables stitching for Code 93 barcodes. When

Strany 51 - Signal Voltage: Normal/TTL

Symbologies136MagellanTM 1100i MSI/PlesseyThe following options apply to the MSI/Plessey symbology.Disable/Enable MSI/PlesseyWhen this feature is disa

Strany 52 - Beep on Not on File

MSI/PlesseyProduct Reference Guide 137MSI/Plessey — continuedCheck Digit TransmitWhen this option is enabled, the scanner w

Strany 53 - ACK NAK Options

Symbologies138MagellanTM 1100iMSI/Plessey — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will deco

Strany 54 - NAK Character

MSI/PlesseyProduct Reference Guide 139MSI/Plessey — continuedMSI/Plessey Length 1, Length 2 Programming Instructions1. Scan

Strany 55 - ACK NAK Timeout Value

Symbologies140MagellanTM 1100iMSI/Plessey — continuedMSI/Plessey StitchingEnables/disables stitching for MSI/Plessey barcodes. When parts of an MSI/Pl

Strany 56 - ACK NAK Retry Count

MSI/PlesseyProduct Reference Guide 141MSI/Plessey — continuedMinimum ReadsThis feature specifies the minimum number of cons

Strany 57 - ACK NAK Error Handling

Product Reference Guide7Chapter 2General FeaturesDouble Read Timeout for Linear LabelsThis Double Read Timeout feature sets a time limit that determin

Strany 58 - USB-OEM Interface Features

Symbologies142MagellanTM 1100iStandard 2 of 5The following options apply to the Standard 2 of 5 symbology.Disable/Enable Standard 2 of 5When this feat

Strany 59

Standard 2 of 5Product Reference Guide 143Standard 2 of 5 — continuedCheck Digit TransmitWhen this option is enabled, the s

Strany 60 - USB Keyboard

Symbologies144MagellanTM 1100iStandard 2 of 5 — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will

Strany 61 - Keyboard Wedge — cont

Standard 2 of 5Product Reference Guide 145Standard 2 of 5 — continuedStandard 2 of 5 Length 1, Length 2 Programming Instruc

Strany 62

Symbologies146MagellanTM 1100iStandard 2 of 5 — continuedStandard 2 of 5 StitchingEnables/disables stitching for Standard 2 of 5 barcodes. When parts

Strany 63

Standard 2 of 5Product Reference Guide 147Standard 2 of 5 — continuedMinimum ReadsThis feature specifies the minimum number

Strany 64

Symbologies148MagellanTM 1100iNOTES

Strany 65

Product Reference Guide1492D SymbologiesNOTEThe features in this section are available ONLY for models with 2D features activated.2D SymbologiesThe sc

Strany 66 - USB COM Interface Set-up

2D Symbologies150MagellanTM 1100iPDF 417Disable/Enable PDF 417When disabled, the scanner will not read PDF 417 barcodes.START / ENDPROGRAMMING BARCODE

Strany 67 - Data Editing

2D SymbologiesProduct Reference Guide 151PDF 417 — continuedLength ControlFixed Length Decoding— When fixed length decoding

Strany 68 - Global Prefix/Suffix

General Features8MagellanTM 1100iDouble Read Timeout for Linear Labels — cont.START / ENDPROGRAMMING BARCODES0.7 Second0.8 Second0.9 Second1 Second

Strany 69 - Global Prefix/Suffix — cont

2D Symbologies152MagellanTM 1100iPDF 417 — continuedPDF 417 Length 1, Length 2 Programming Instructions1. Scan the START barcode.2. Scan either the Se

Strany 70

2D SymbologiesProduct Reference Guide 153Micro PDF 417Disable/Enable Micro PDF 417When disabled, the scanner will not read

Strany 71 - Label ID

2D Symbologies154MagellanTM 1100iMicro PDF 417 — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will

Strany 72 - Label ID — cont

2D SymbologiesProduct Reference Guide 155Micro PDF 417 — continuedMicro PDF 417 Length 1, Length 2 Programming Instructions

Strany 73

2D Symbologies156MagellanTM 1100iDatamatrixDisable/Enable DatamatrixWhen disabled, the scanner will not read Datamatrix barcodes.START / ENDPROGRAMMIN

Strany 74

2D SymbologiesProduct Reference Guide 157Datamatrix — continuedLength ControlFixed Length Decoding— When fixed length decod

Strany 75

2D Symbologies158MagellanTM 1100iDatamatrix — continuedDatamatrix Length 1, Length 2 Programming Instructions1. Scan the START barcode.2. Scan either

Strany 76

2D SymbologiesProduct Reference Guide 159QR CodeDisable/Enable QR CodeWhen disabled, the scanner will not read QR Code labe

Strany 77

2D Symbologies160MagellanTM 1100iQR Code — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will decod

Strany 78 - Case Conversion

2D SymbologiesProduct Reference Guide 161QR Code — continuedQR Code Length 1, Length 2 Programming Instructions1. Scan the

Strany 79 - Character Conversion

Double Read Timeout for 2D LabelsProduct Reference Guide 9Double Read Timeout for 2D LabelsThis Double Read Timeout feature

Strany 80

2D Symbologies162MagellanTM 1100iMaxicodeDisable/Enable MaxicodeWhen disabled, the scanner will not read Maxicode labels.START / ENDPROGRAMMING BARCOD

Strany 81

2D SymbologiesProduct Reference Guide 163Maxicode — continuedLength ControlFixed Length Decoding— When fixed length decodin

Strany 82 - UPC-A — continued

2D Symbologies164MagellanTM 1100iMaxicode — continuedMaxicode Length 1, Length 2 Programming Instructions1. Scan the START barcode.2. Scan either the

Strany 83

2D SymbologiesProduct Reference Guide 165AztecDisable/Enable AztecWhen disabled, the scanner will not read Aztec labels.STA

Strany 84

2D Symbologies166MagellanTM 1100iAztec — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will decode

Strany 85 - Check Digit Transmission

2D SymbologiesProduct Reference Guide 167Aztec — continuedAztec Length 1, Length 2 Programming Instructions1. Scan the STAR

Strany 86 - UPC-E — continued

2D Symbologies168MagellanTM 1100iComposite LabelsDisable/Enable GS1 DataBar Omnidirectional 2D ComponentWhen enabled, if a GS1 DataBar Omnidirectional

Strany 87

2D SymbologiesProduct Reference Guide 169Disable/Enable GS1 DataBar Limited 2D ComponentWhen enabled, if a GS1 DataBar Limi

Strany 88 - Expand UPC/EAN to GTIN

2D Symbologies170MagellanTM 1100iNOTES

Strany 89 - Disable/Enable EAN-13

Product Reference Guide171Advanced Decoding FeaturesPharmacy PatternsEnables/disables using the pharmacy patterns.START / ENDPROGRAMMING BARCODES

Strany 90 - EAN-13 — continued

General Features10MagellanTM 1100iLabel Gone TimeoutThis feature sets the time after the last label segment is seen before the scanner prepares for a

Strany 91

Advanced Decoding Features172MagellanTM 1100iInverse Label ReadingThis controls the method of reading inverse labels (white label on black background)

Strany 92 - Disable/Enable EAN-8

Product Reference Guide173Chapter AProduct SpecificationsOptical and Read Performance ParametersParameter SpecificationScan Volume 70 cubic inchesScan

Strany 93 - EAN-8 — continued

174MagellanTM 1100iPhysical PropertiesParameter SpecificationDimensions (Scanner only):3.3” x2.8” x3.7”Dimensions (Scanner w/Base Station):5.5” x2.9”

Strany 94 - EAN Two-Label

Product Reference Guide175Chapter BCable PinoutsStandard Cable Pinouts (Primary Interface Cables)RS-23212CTS34RTS5RXD6TXD78 VCC IN9GND10Pin 1

Strany 95 - EAN Two-Label — continued

Cable Pinouts176MagellanTM 1100iUSB-OEM1 2 3 4D -56D +78VIN9GND10Pin 110 Position RJ(Scanner End)USB, USB Keyboard1 2 3 4D -56D +78 VB

Strany 96

ABCDEF Product Reference Guide177Chapter CAlpha-Numeric Pad

Strany 97

178MagellanTM 1100iAlpha-Numeric Pad1230987654

Strany 98

Product Reference Guide179Appendix DDefault SettingsDefaults by SymbologyCode TypeReadEnableChecksumVerificationEnableChecksumTransmissionEnableLabelI

Strany 99

180MagellanTM 1100iInterface Default ExceptionsThe factory default settings indicated in the programming sections (in bold text) reflect factory confi

Strany 100 - Price Weight Check Digit

Interface Default ExceptionsProduct Reference Guide 181Interface Default Exceptions — continuedRS-232 Wincor/NixdorfParamet

Strany 101 - Contact Customer Support for

Sleep ModeProduct Reference Guide 11Sleep ModeThis feature specifies the amount of time with no barcode reads before the sc

Strany 102 - Add-ons — continued

182MagellanTM 1100iInterface Default Exceptions — continuedKeyboardsKeyboard interfaces include USB Keyboard and Keyboard Wedge A-JParameter Default S

Strany 103

Product Reference Guide183Appendix EKeyboard Function Key MappingsKeyboard Model Cross ReferenceTable E-1 summarizes the keyboard models, their define

Strany 104

184MagellanTM 1100iTable E-2. USB Function Key Usage MapASCII Key value Usage Name Modifier/Scancode00 NUL ALT right Make 40h 00h01 SOH ALT right

Strany 105 - UCC/EAN 128 Emulation

Keyboard Model Cross ReferenceProduct Reference Guide 185Table E-3ASCII (hex)ASCII code Key Scancode00 NULALT right Make

Strany 106 - Minimum Reads

186MagellanTM 1100iTable E-5ASCII (hex) ASCII code Key Scancode00 NULALT right Make 39h01 SOH ALT right Break F0h 39h02 STX ALT left Make 19h 03 ETX A

Strany 107 - GS1-128 Emulation

Keyboard Model Cross ReferenceProduct Reference Guide 187Table E-6. ASCII (hex) ASCII code Key Scancode00 NULALT Right Make

Strany 108 - Length Control

188MagellanTM 1100iTable E-7. ASCII value ASCII code Key Scancode00h NULALT right Make31h01h SOH ALT right BreakB1h02h STX ALT left Make31h03h ETX ALT

Strany 109

Keyboard Model Cross ReferenceProduct Reference Guide 189Table E-8. NEC 9801-Key Function Key MapASCII value ASCII code Key

Strany 110

190MagellanTM 1100iNOTES

Strany 111 - Coupon Read Control

Product Reference Guide191Chapter FHost CommandsAccepting RS-232 CommandsThe scanner responds to the following RS-232 commands:COMMAND ASCII HEX COMME

Strany 112 - GS1 DataBar Limited

Datalogic ADC, Inc.959 Terry StreetEugene, OR 97402USATelephone: (541) 683-5700Fax: (541) 345-7140© 2005-2014 Datalogic ADC, Inc.An Unpublished Work -

Strany 113

General Features12MagellanTM 1100iSleep Mode — cont.START / ENDPROGRAMMING BARCODES6 Minutes7 Minutes8 Minutes9 Minutes10 MinutesDEFAULT12 Minutes15 M

Strany 115 - Start/Stop Characters

Product Reference Guide193Chapter GSample Symbols1D Symbol Samples0 1234567890UPC-A051234567890Interleaved 2 of 5Code 128Code 1289 780330 290951EAN

Strany 116 - Code 39 Full ASCII

194MagellanTM 1100i1D Symbol Samples — continued0100123456789050GS1 DataBar Expanded(01)00123456789012GS1 DataBar Omnidirectional123456Code 2 of 5

Strany 117 - Code 39 — continued

2D Sample SymbolsProduct Reference Guide 1952D Sample Symbols

Strany 118 - Quiet Zones

196MagellanTM 1100iComposite Sample SymbolsGS1 DataBar Limited CompositeGS1 DataBar Truncated Composite

Strany 119

Composite Sample SymbolsProduct Reference Guide 197NOTES

Strany 121

ASCII ChartASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.HexNo.NULSOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSIDLEDC1DC2DC3DC4NAKSYNETBCANE

Strany 122 - Code 128

820034314 (Rev.F) November 2013www.datalogic.com© 2005-2013 Datalogic ADC, Inc. • All rights reserved. • Datalogic and the Datalogic logo are registe

Strany 123 - Code 128 — continued

LED and Beeper IndicatorsProduct Reference Guide 13LED and Beeper IndicatorsPower On AlertDisables or enables the indicatio

Strany 124

General Features14MagellanTM 1100iERI TimeoutSpecifies the amount of time the External Read Indicator (ERI) signal is held active for a good read.STAR

Strany 125

LED and Beeper IndicatorsProduct Reference Guide 15Good Read: When to IndicateThis feature specifies when the scanner will

Strany 126

General Features16MagellanTM 1100iGood Read Beep ControlThis feature enables/disables the scanner’s ability to beep upon a successful decode of a bar-

Strany 127 - Interleaved 2 of 5

LED and Beeper IndicatorsProduct Reference Guide 17Good Read Beep LengthSpecifies the duration of a good read beep.START /

Strany 128 - Check Digit Transmit

General Features18MagellanTM 1100iGood Read Beep VolumeSelects the beeper volume (loudness) upon a good read beep. There are three selectable vol-ume

Strany 129

LED and Beeper IndicatorsProduct Reference Guide 19Aiming Pointer SettingsEnabes/disables Aiming Pointer for all symbologie

Strany 130 - Symbologies

General Features20MagellanTM 1100iScanning FeaturesTargeted Scanning ModeUpon pressing the button, the scanner will project an aiming pattern to assis

Strany 131 - Interleaved 2 of 5 Stitching

Scanning FeaturesProduct Reference Guide 21Target Mode Linger Time Specifies the time duration the scanner remains in the t

Strany 132

Product Reference Guide iTable of ContentsChapter 1. Getting Started...

Strany 133 - Check Character Verification

General Features22MagellanTM 1100iWake Up IntensityThis feature indicates the percentage of ambient light change which will trigger the scanner to wak

Strany 134

Image CaptureProduct Reference Guide 23Wake Up Intensity — cont.Image CaptureNOTEThis function is ONLY available for scanne

Strany 135 - Codabar — continued

General Features24MagellanTM 1100iImage CompressionSpecifies the starting image compression factor for JPEG images. A higher number specifies a higher

Strany 136

Image CaptureProduct Reference Guide 25Image BrightnessThis feature sets the image brightness value. Follow these instructi

Strany 137

General Features26MagellanTM 1100iCell Phone ModeCell Phone Mode enables the scanner to read barcodes on a cell phone display.Cell Phone Mode EnableEn

Strany 138 - Codabar Stitching

Cell Phone ModeProduct Reference Guide 27Cell Phone Detection SensitivityThese settings control various pixel characteristi

Strany 139

START / ENDPROGRAMMING BARCODESCell Phone Detection Sensitivity = MEDIUM[This is the DEFAULT setting]MEDIUM #1MEDIUM #2 MEDIUM #3Cell Phone Detection

Strany 140 - Disable/Enable Code 93

Cell Phone ModeProduct Reference Guide 29Cell Phone in Target ModeThis feature sets the reader’s Cell Phone Mode when it is

Strany 141 - Code 93 — continued

General Features30MagellanTM 1100iCell Phone in Target Mode — continuedSTART / ENDPROGRAMMING BARCODESCell Phone in Target Mode = Auto Detection Cell

Strany 142

Product Reference Guide31Chapter 3Interface Related FeaturesAt the time of this writing, the reader supports the interfaces listed in Table 3-1. Selec

Strany 143

iiMagellanTM 1100iACK NAK Options ...

Strany 144 - MSI/Plessey

Interface Related Features32MagellanTM 1100iTable 3-2I/F TypePCs SupportedA PC/XT w/Alternate Key EncodingBAT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 8

Strany 145 - MSI/Plessey — continued

Interface SelectionProduct Reference Guide 33Interface SelectionSTART / ENDPROGRAMMING BARCODESRS-232 StandardRS-232 Wincor

Strany 146

Interface Related Features34MagellanTM 1100iInterface Selection — cont.START / ENDPROGRAMMING BARCODESKeyboard Wedge AKeyboard Wedge BKeyboard Wedge C

Strany 147

Interface FeaturesProduct Reference Guide 35Interface FeaturesObey/Ignore Host CommandsWhen set to ignore host commands, th

Strany 148

Interface Related Features36MagellanTM 1100iInterface Features — cont.Host Transmission BuffersSpecifies the number of host transmission(s) that may b

Strany 149

Interface FeaturesProduct Reference Guide 37RS-232 Interface FeaturesSTART / ENDPROGRAMMING BARCODES 1200 Baud2400 Baud 48

Strany 150 - Standard 2 of 5

Interface Related Features38MagellanTM 1100iRS-232 Interface Features — cont.START / ENDPROGRAMMING BARCODES7 Data Bits8 Data BitsDEFAULT1 Stop BitDEF

Strany 151 - Standard 2 of 5 — continued

Interface FeaturesProduct Reference Guide 39RS-232 Interface Features — cont.Hardware Flow ControlDisable Hardware Control—

Strany 152

Interface Related Features40MagellanTM 1100iRS-232 Interface Features — cont.Intercharacter DelayThis delay is inserted after each data character tran

Strany 153

Interface FeaturesProduct Reference Guide 41Intercharacter Delay — cont.Software Flow ControlDisables/Enables software cont

Strany 154

Product Reference Guide iii2-Digit Addons Minimum Reads ...

Strany 155

Interface Related Features42MagellanTM 1100iRS-232 Interface Features — cont.Host Echo Quiet IntervalThis setting specifies the time interval of RS-23

Strany 156

Interface FeaturesProduct Reference Guide 43Host Echo Quiet Interval — cont.Signal Voltage: Normal/TTLSpecifies whether the

Strany 157 - 2D Symbologies

Interface Related Features44MagellanTM 1100iBeep on ASCII BELEnables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCI

Strany 158 - Disable/Enable PDF 417

Interface FeaturesProduct Reference Guide 45ACK NAK OptionsThis enables/disables the ability of the scanner to support the

Strany 159 - PDF 417 — continued

Interface Related Features46MagellanTM 1100iRS-232 Interface Features — cont. — cont.ACK CharacterSTART / ENDPROGRAMMING BARCODESSets the ACK characte

Strany 160

Interface FeaturesProduct Reference Guide 47RS-232 Interface Features — cont.Retry on ACK NAK TimeoutEnables/disables retry

Strany 161 - Micro PDF 417

Interface Related Features48MagellanTM 1100iRS-232 Interface Features — cont.ACK NAK Retry CountSTART / ENDPROGRAMMING BARCODESThis feature sets the n

Strany 162 - Micro PDF 417 — continued

Interface FeaturesProduct Reference Guide 49RS-232 Interface Features — cont.ACK NAK Error HandlingThis item specifies the

Strany 163

Interface Related Features50MagellanTM 1100iRS-232 Interface Features — cont.Transmission Failure IndicationEnables/disables bad-label indication upon

Strany 164 - Datamatrix

Interface FeaturesProduct Reference Guide 51IBMIBM Transmit Labels in Code 39 FormatThis feature enables/disables scanner&a

Strany 165 - Datamatrix — continued

ivMagellanTM 1100iCode 93 ...

Strany 166

Interface Related Features52MagellanTM 1100iKeyboard WedgeandUSB KeyboardAs a keyboard interface, the scanner supports most popular PCs and IBM termin

Strany 167 - Disable/Enable QR Code

Interface FeaturesProduct Reference Guide 53Keyboard Wedge — cont.START / ENDPROGRAMMING BARCODESItalyNorwayPortugalSpainSw

Strany 168 - QR Code — continued

Interface Related Features54MagellanTM 1100iKeyboard Wedge — cont.Caps Lock StateSpecifies the format in which the scanner sends character data.START

Strany 169

Interface FeaturesProduct Reference Guide 55Keyboard Wedge — cont.Power-On SimulationNOTEThis feature does not apply to the

Strany 170 - Maxicode

Interface Related Features56MagellanTM 1100iControl CharactersSpecifies how the scanner transmits ASCII control characters to the host. Choices are:•

Strany 171 - Maxicode — continued

Interface FeaturesProduct Reference Guide 57Keyboard Wedge — cont.Wedge Quiet IntervalNOTEThis feature does not apply to th

Strany 172

Interface Related Features58MagellanTM 1100iKeyboard Wedge — cont.Intercharacter DelaySTART / ENDPROGRAMMING BARCODESOne-half of the delay specified b

Strany 173 - Disable/Enable Aztec

Product Reference Guide59Chapter 4Data EditingData Editing OverviewCAUTIONIt is not recommended to use these features with IBM interfaces.When a barc

Strany 174 - Aztec — continued

Data Editing60MagellanTM 1100iGlobal Prefix/SuffixUp to 20 ASCII characters may be added as a prefix (in a position before the barcode data) and/or as

Strany 175

Global Prefix/SuffixProduct Reference Guide 61Global Prefix/Suffix — cont.START / ENDPROGRAMMING BARCODESSets up to 20 char

Strany 176 - Composite Labels

Product Reference Guide vScanner Dimensions ...

Strany 177

Data Editing62MagellanTM 1100iAIM IDAIM (Automatic Identification Manufacturers) label identifiers are assigned from a globally standardized list — as

Strany 178

Label IDProduct Reference Guide 63Label IDA Label ID is used to identify a barcode (symbology) type. See Appendix D, Defaul

Strany 179 - Advanced Decoding Features

Data Editing64MagellanTM 1100iLabel ID — cont.START / ENDPROGRAMMING BARCODESLabel ID Transmission: DisableLabel ID Position: Before Barcode DataDEFAU

Strany 180 - Inverse Label Reading

Label IDProduct Reference Guide 65Label ID — cont.START / ENDPROGRAMMING BARCODESDEFAULT SETTING FOR THIS FEATURE: E (45 he

Strany 181 - Product Specifications

Data Editing66MagellanTM 1100iLabel ID — cont.START / ENDPROGRAMMING BARCODESDEFAULT SETTING FOR THIS FEATURE: F (46 hex)Set EAN-13 w/P2 Addon Label I

Strany 182 - Other Parameters

Label IDProduct Reference Guide 67Label ID — cont.START / ENDPROGRAMMING BARCODESDEFAULT SETTING FOR THIS FEATURE: G8 (4738

Strany 183 - Cable Pinouts

Data Editing68MagellanTM 1100iLabel ID — cont.START / ENDPROGRAMMING BARCODESDEFAULT SETTING FOR THIS FEATURE: % (25 hex)Set Codabar Label ID Characte

Strany 184 - Keyboard Wedge

Label IDProduct Reference Guide 69Label ID — cont.NOTEFor the 2D symbologies on this page, the Label ID is 4 bytes. The fi

Strany 185 - Alpha-Numeric Pad

Data Editing70MagellanTM 1100iCase ConversionThis feature can convert scanned barcode data to either all lower case (a through z) or all upper case (A

Strany 186

Character ConversionProduct Reference Guide 71Character ConversionCharacter conversion is an eight byte configuration item.

Strany 187 - Default Settings

viMagellanTM 1100iNOTES

Strany 188 - Interface Default Exceptions

Data Editing72MagellanTM 1100iNOTES

Strany 189 - RS-232 Wincor/Nixdorf

Product Reference Guide73Chapter 5SymbologiesThe scanner supports the following symbologies (barcode types). Options for each symbology are included i

Strany 190 - Keyboards

Symbologies74MagellanTM 1100iUPC-A — continuedCheck Digit TransmissionEnable this option to transmit the check digit along with UPC-A barcode data.STA

Strany 191 - Appendix E

UPC-AProduct Reference Guide 75UPC-A — continuedNumber System TransmissionThis feature enables/disables transmission of UPC

Strany 192

Symbologies76MagellanTM 1100iUPC-A — continuedUPC-A In-store Minimum ReadsThis feature specifies the minimum number of consecutive times an in-store p

Strany 193

UPC-EProduct Reference Guide 77UPC-EThe following options apply to the UPC-E symbology.Disable/Enable UPC-EWhen disabled, t

Strany 194

Symbologies78MagellanTM 1100iUPC-E — continuedNumber System DigitThe Number System Digit (NSD) which is always a zero (0) in the leading position can

Strany 195

UPC-EProduct Reference Guide 79UPC-E — continuedExpand UPC-E to EAN13Enables/disables expansion of UPC-E labels to EAN-13.

Strany 196

Symbologies80MagellanTM 1100iGTINThe following options apply to the GTIN label data format.Expand UPC/EAN to GTINWhen this feature is enabled, the sca

Strany 197

EAN-13Product Reference Guide 81EAN-13The following options apply to the EAN-13 symbology.Disable/Enable EAN-13When disable

Strany 198

Product Reference Guide1Chapter 1Getting StartedThe MagellanTM 1100i Omni-Directional Imaging Scanner offers hands-free scanning for small, easily han

Strany 199 - Host Commands

Symbologies82MagellanTM 1100iEAN-13 — continuedEAN-13 Flag 1 CharacterEnables/disables transmission of an EAN/JAN13 Flag1 character.START / ENDPROGRAM

Strany 200

EAN-13Product Reference Guide 83EAN-13 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive tim

Strany 201 - Sample Symbols

Symbologies84MagellanTM 1100iEAN-8The following options apply to the EAN-8 symbology.Disable/Enable EAN-8When disabled, the scanner will not read EAN-

Strany 202 - 1D Symbol Samples — continued

EAN-8Product Reference Guide 85EAN-8 — continuedExpand EAN-8 to EAN-13— Expands EAN-8 data to the EAN-13 data format. Selec

Strany 203 - 2D Sample Symbols

Symbologies86MagellanTM 1100iEAN Two-LabelEnables/disables the ability of the scanner to decode EAN two-label pairs.START / ENDPROGRAMMING BARCODES Di

Strany 204 - Composite Sample Symbols

EAN Two-LabelProduct Reference Guide 87EAN Two-Label — continuedEAN Two-Label Type 2Specifies label types and number of fla

Strany 205 - 197

Symbologies88MagellanTM 1100iEAN Two-Label — continuedEAN Two-Label Type 3Specifies label types and number of flag digits for EAN/JAN two-label pair 3

Strany 206

EAN Two-LabelProduct Reference Guide 89EAN Two-Label — continuedEAN Two-Label Type 4Specifies label types and number of fla

Strany 207 - ASCII Chart

Symbologies90MagellanTM 1100iEAN Two-Label — continuedEAN Two-Label Combined TransmissionEnables/disables the transmitting of an EAN two label pair as

Strany 208 - Datalogic ADC, Inc

EAN Two-Label Combined TransmissionProduct Reference Guide 91EAN Two-Label — continuedEAN Two-Label Minimum ReadsThis featu

Komentáře k této Příručce