Interface Related Features
3-48 PowerScan® 7000 SRI
Keyboard Wedge/USB Keyboard — cont.
Wedge Quiet Interval
Quiet Interval is the amount of time to look for keyboard activity before
the scanner breaks the keyboard connection in order to transmit data to
the host..
NOTE
This feature does not apply to the USB Keyboard
interface.
START
MODE BAR CODE
Selectable from 000 (no interval) to 255 in 10 msec
increments. To configure this feature, scan the
“START” bar code above to place the unit in Pro-
gramming Mode, then the
Set Wedge Quiet Inter-
val
bar code followed by the three digits (zero
padded) from the Alphanumeric table in
Appendix C, Alpha-Numeric Pad representing
your desired length. Exit programming mode by
scanning the “END” BAR CODE below
DEFAULT SETTING FOR THIS FEATURE:
010 (100 msec)
Set Wedge
Quiet Interval
END