Programming Guide 9
IBM 4683/84 • 4693/94 Port 5B Interface Selection
Scan this label to enable the IBM 468x Port 5B interface.
IBM 4683/84 • 4693/94 Port 5B Settings
Data Format: Send As Code 39 — converts bar code data (UPC/EAN,
add-ons, Code 93, Codabar, MSI/Plessey and Code 128) into Code 39
format before sending the data to the host.
These settings are for IBM 4683/84 • 4693/94 Port 5B interface ONLY.
Limit Command Set — is an option that causes the scanner to ignore
'enable scanner' and 'disable scanner' commands sent from the host.
Transmit Unsolicited Status
1
— when enabled, this option causes the
scanner to transmit a status message to the host upon receipt of an "SNRM".
SET ----------------------------------------------
SEND AS CODE 39 ----------------
DON'T SEND AS CODE 39 --------
ENABLE LIMIT COMMAND SET -----
DISABLE LIMIT COMMAND SET -----
TRANSMIT UNSOLICITED STATUS ---
DON'T TRANSMIT UNSOLICITED STATUS ---
END ----------------------------------------------
1 For this IBM interface, the setting for Unsolicited Status is normally Enabled.