Technical Specifications
26 QuickScan™ QD2430
User Environment
Operating Temperature 0° to 50° C (32° to 122° F)
Storage Temperature -40° to 70 °C (-40° to 158° F)
Humidity
Operating: 0% to 95% relative humidity,
non-condensing
Drop Specifications
Scanner withstands 18 drops from 1.5 meters (5.0 feet) to
concrete
Ambient Light Immunity Up to 86,000 Lux
Contaminants Spray/rain Dust/
particulates
IEC 529-IP42
ESD Level 16 KV
Regulatory
Electrical Safety UL 60950, CSA C22.2 No. 60950, IEC 60950
EMI/RFI
North America (FCC) : Part 15 Class B; Canada ( IC) : ICES-
003 Class B; Russia ( Gost); European Union EMC Directive;
VCCI-Japan; Korean KCC; Taiwan EMC (BSMI);
Australia (ACMA); Mexico (NOM)