Datalogic™ OPOS Service Objects
RTSControl – defaulted to active. Service will set CTS line active at the
host port and leave it set high.
StopBits – defaulted to 1, same caveat as for baud rate.
RS232Scanner = QS6000
Common fields as above; in addition the following field is:
IncludeCR – This will add a {0x0D} to the end of barcodes. Default
off.
TransmitUnknown - when set to 0, the service will not send barcodes
to the application if the symbology is unknown. When set to 1, all bar-
code data will be sent to the application, regardl
ess of the value of
ScanDataLabel (symbology type). Default is 0.
WarholParsing – defaults to not active. When using a QD21xx,
QD23xx, PD71xx, or GD41xx handheld scanner, the user should set
this to active and select the “
RS232 OPOS” interface in the scanner
programming guide. This setting enables correct identification of Label
Ids from the scanner through the Service Object.