Datalogic™ OPOS Service Objects
DataCount:
Returns the number of Data Events Queued.
DataEventEnabled:
Returns TRUE or FALSE depending on the previous SetProperty call.
DeviceEnabled:
Returns TRUE or FALSE depending on the previous SetProperty call.
FreezeEvents:
Returns TRUE or FALSE depending on the previous SetProperty call.
OpenResult:
Returns 0.
PowerNotify:
Returns OPOS_PN_DISABLED or OPOS_PN_ENABLED.
PowerState:
Returns OPOS_PS_ONLINE.
If the communication channel is having difficulties, an
OPOS_E_NOHARD-
WARE will be returned on calls that send and receive data from the scanner.
If PowerNotify is set to "OPOS_PN_ENABLED", then:
If the Scanner is Plugged and Enabled:
OPOS_PS_ONLINE
•otherwise:
OPOS_PS_OFF_OFFLINE
ResultCode:
Returns result of last operation.
ResultCodeExtended:
Returns 0
State:
Returns
OPOS_S_CLOSED
OPOS_S_IDLE
OPOS_S_ERROR
DeviceServiceDescription:
Returns a descriptive string depending on the interface and device type.
DeviceServiceVersion:
Returns 101200XX. where XX is the minor version.