Datalogic QLM700 Manuál s instrukcemi Strana 152

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 160
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 151
MATRIX 300™ REFERENCE MANUAL
140
A
OUTPUTS
Three general purpose non opto-isolated but short circuit protected outputs are available on
the M12 17-pin connector. See par. 4.6 for more details.
The pinout is the following:
Pin
Name
Function
9
O1
Configurable digital output 1
8
O2
Configurable digital output 2
16
O3
Configurable digital output 3
2
GND
Ouptut reference signal
The electrical features of the three outputs are the following:
Reverse-Polarity and Short-Circuit Protected
V
OUT
(I
LOAD
= 0 mA) max = 30 Vdc
V
OUT
(I
LOAD
= 100 mA) max = 3 Vdc
I
LOAD
max = 100 mA
The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the two. Refer to
the Digital I/O folder in the VisiSet™ Help On Line for further details.
PNP
Matrix 300™
USER INTERFACE
9/8/16
2
Vdc
Figure 95 - PNP Output Connection
Matrix 300™
USER INTERFACE
Vext
9/8/16
2
Vdc
Figure 96 - NPN Output Connection
Zobrazit stránku 151

Komentáře k této Příručce

Žádné komentáře