MATRIX 300™ REFERENCE MANUAL
74
5
5.3 ID-NET™ MULTIDATA NETWORK
For a Master/Slave Multidata layout each reader has its own reading phase independent
from the others; each single message is sent from the master reader to the Host computer.
Figure 67 ID-NET™ M/S Multidata
NOTE: The auxiliary serial interface of the slave readers can be used in
Local Echo communication mode to control any single reader (visualize
collected data) or to configure it using the VisiSet™ utility.
The ID-NET™ termination resistor switches must be set to ON only in the first
and last CBX connection box.
Terminal
Main Serial Interface (RS232 or RS485/422 Full-Duplex)
Auxiliary Serial Interface (Local Echo) (RS232)
External Trigger (for One Shot or Phase Mode)
ID-NET™ (up to 32 devices, max network extension of 1000 m)
Host
1
4
3
2
Master
Slave#1
Slave#n
Power