Strany 1 - Datalogic Jet™

Datalogic Jet™User’s Manual

Strany 2

SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection to the Datalogic Jet™ PDA. The user is responsible for

Strany 3

LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both La

Strany 4

ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your PDA

Strany 5 - CONTENTS

DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen

Strany 6

ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso cor

Strany 7

The following shows the correspondence between the Datalogic Jet™ models and the Radio modules:  Datalogic Jet™ 5XX-XXX-XXX 802.11b (Wi-Fi) radio c

Strany 8

GENERAL VIEW xiv A Figure A – General View A) Data capture/Laser output window B) Scan key(s) (3) C) Bluetooth® LED D) Charging

Strany 9 - REFERENCES

INTRODUCTION 1 1 INTRODUCTION 1.1 DATALOGIC JET™ PDA DESCRIPTION The Datalogic JET™, is the powerful Datalogic PDA. Thanks to the state-of the-art

Strany 10 - SAFETY REGULATIONS

DATALOGIC JET™ 1 1.2 AVAILABLE MODELS The brand new Datalogic Jet™ PDA is available in different models depending on the options it is equipped with.

Strany 11 - LASER SAFETY

INTRODUCTION 1 1.4 INSERTING MINI SD CARD With Datalogic JET™ PDA, it is possible to add a Mini SD Card for additional storage capacity. To access t

Strany 13 - ATTENTION

DATALOGIC JET™ 1 1.5 ACCESSORIES  Cradles 94A151096 Datalogic Jet™ Single Cradle Desk (includes slot for spare battery pack recharge; RS232 and USB

Strany 14 - RADIO COMPLIANCE

CONNECTIONS 2 2 CONNECTIONS 2.1 PDA CONNECTION TO THE HOST COMPUTER 2.1.1 RS232/USB Direct Connection You can use a cable to connect the Datalo

Strany 15 - INFORMATION FOR THE USER

DATALOGIC JET™ 2 2.1.2 WLAN Connection Datalogic Jet™ Wi-Fi models can communicate with the host using the on-board radio frequency module and an Acc

Strany 16 - GENERAL VIEW

CONNECTIONS 7 2 2.1.3 WPAN Connection Datalogic Jet™ PDAs can communicate with a Bluetooth® device, such as a printer, within a range of 10 m, using

Strany 17 - 1 INTRODUCTION

DATALOGIC JET™ 2 2.1.4 WWAN Connection Datalogic Jet™ GSM/GPRS models enhance your connectivity solutions giving you an opening to an international w

Strany 18 - 1.3 PACKAGE CONTENTS

CONNECTIONS 2 Installing the SIM Card To correctly insert the SIM Card, proceed as follows: 1- Turn off the Datalogic Jet™ PDA. 2- Press the latch

Strany 19 - 1.4 INSERTING MINI SD CARD

DATALOGIC JET™ 2 4- Open the Sim Card slot by pulling up the locking plate. 5- Pull up the cardholder and insert the Sim Card with its contacts

Strany 20 - 1.5 ACCESSORIES

CONNECTIONS 2 2.2 CONNECTION CABLES The following cables are listed with their order number.  RS232 Direct Connection: 94A051008 WIN-NET SERIAL CA

Strany 21 - 2 CONNECTIONS

DATALOGIC JET™ 3 3 USE AND FUNCTIONING The use of the Datalogic Jet™ PDA depends on the application software loaded. However there are several para

Strany 22 - 2.1.2 WLAN Connection

USE AND FUNCTIONING 3 When it is no longer used for more than a programmable timeout, which is defined in the POWER applet of the Control Panel, the P

Strany 23 - 2.1.3 WPAN Connection

Datalogic Jet™ USER'S MANUAL

Strany 24 - 2.1.4 WWAN Connection

DATALOGIC JET™ 3 3.3 DATA CAPTURE To configure and enable data capture parameters refer to par. 3.6. 3.3.1 Laser Data Capture To scan barcodes, p

Strany 25 - Installing the SIM Card

USE AND FUNCTIONING 3 3.3.2 Imager Data Capture To read a 1D or 2D code, simply point the Datalogic Jet™ Imager model onto the code from a distance

Strany 26 - Removing the SIM Card

DATALOGIC JET™ 3 Linear barcode 2D Matrix symbol ÌBX3ÉÎ Relative Size and Location of Aiming System Pattern The field of view changes its size as

Strany 27 - 2.2 CONNECTION CABLES

USE AND FUNCTIONING 17 3 3.4 DESCRIPTION OF THE KEYS The Datalogic Jet™ PDA provides a function-oriented keyboard having a total of 27 keys. The ke

Strany 28 - 3 USE AND FUNCTIONING

DATALOGIC JET™ 3 By pressing these keys simultaneously, a system software reset is performed. By pressing these keys simultaneousl

Strany 29 - 3.2 USING THE STYLUS

USE AND FUNCTIONING 3 Some of these keys carry extra symbols and are logically divided in up to 3 sections according to the following figure: A B

Strany 30 - 3.3.1 Laser Data Capture

DATALOGIC JET™ 3 Switches on/off the keyboard backlight. Both display and keyboard backlight automatically turn off after a timeout, depending on Con

Strany 31 - 3.3.2 Imager Data Capture

USE AND FUNCTIONING 3 3.5.2 Status Bar The Status Bar provides information about the time, the battery level, the keyboard function, and the decoding

Strany 32 - 3.3.3 RFID Data Capture

DATALOGIC JET™ 3 3.6 DATA CAPTURE CONFIGURATION From the Taskbar, tap the "Data Capture" icon to open a drop–down menu. Data Capture can a

Strany 33 - 3.4 DESCRIPTION OF THE KEYS

USE AND FUNCTIONING 3 Data Capture Configuration Window The screen format shows two columns where the left column indicates branches or parameters.

Strany 34 - .4.2 Key Selection

DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy Datalogic Jet™ - User's Manual Ed.: 03/2006

Strany 35 - USE AND FUNCTIONING

DATALOGIC JET™ 3 Alternatively using the stylus, you can tap once directly on the value on the right column; continue tapping until the desired value

Strany 36 - 3.5.1 LED Status

USE AND FUNCTIONING 3 Default Settings The following tables contain the default values for the major barcode setup parameters, according to the type

Strany 37 - 3.5.2 Status Bar

DATALOGIC JET™ 3 BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS HP Laser Imager RFID+Laser MSI Enabled Disabled Plessey Disabled Code 93 Disabled

Strany 38 - 3.6.1 Configure

USE AND FUNCTIONING 3 Data Capture can also be enabled through the Configuration applet by selecting File ->Scanner from the main menu, or by enabl

Strany 39

DATALOGIC JET™ 3 3.7.1 Buttons The BUTTONS Applet allows assigning desired applications to be launched by the Act button or one of the function keys

Strany 40 - Scan Parameters

USE AND FUNCTIONING 3 3.7.3 Files Admin The FILES ADMIN applet enables control of the permanence of files in the System Folder. Two functions are ava

Strany 41 - Default Settings

DATALOGIC JET™ 3 Safe Setup First Mask Then select \Windows or a relevant sub-directory in the path box. Then, Safe Setup will recognize the new fil

Strany 42 - 3.6.2 Capture

USE AND FUNCTIONING 3 3.7.4 Wireless Communications The WIRELESS COMMUNICATIONS applet provides management of the Wi-Fi Card and of the Bluetooth® an

Strany 43 - 3.7 CONTROL PANEL

DATALOGIC JET™ 3 3.8 WINDOWS CONNECTIONS From the Desktop, double tap on the "Connections" folder to open the following window: Windows C

Strany 44 - 3.7.2 Registry

USE AND FUNCTIONING 3 For example: Synchronize Microsoft Word and Microsoft Excel files between the Datalogic Jet™ PDA and the desktop computer. The f

Strany 45 - 3.7.3 Files Admin

CONTENTS DATALOGIC END USER LICENSE AGREEMENT... v REFERENCES ...

Strany 46 - Safe Setup Second Mask

DATALOGIC JET™ 3 3.8.2 Bluetooth® Manager Device Setup In order to enable a Bluetooth® device for communication with the Datalogic Jet™ PDA you must

Strany 47

USE AND FUNCTIONING 3 3. Tap on the “Me” button to enter the related window; then, tap on the “ON” button to activate the Bluetooth® module. The modu

Strany 48 - 3.8.1 Microsoft® ActiveSync®

DATALOGIC JET™ 3 Once the Discovery procedure has been completed, select the desired Bluetooth® device from the list. It is also possible to digit

Strany 49 - ActiveSync® Remote

USE AND FUNCTIONING 3 3.9 BACKUP DIRECTORY FILE MANAGEMENT All of the Windows CE .NET system files reside in RAM (volatile memory) except for the Ba

Strany 50

DATALOGIC JET™ 4 4 MAINTENANCE NOTE Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge the

Strany 51

MAINTENANCE 4 4.2 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Datalogic Jet™ PDA. 2. Pre

Strany 52

DATALOGIC JET™ 4 4. Replace the battery pack by pressing the latch release button and pulling the battery latch down, and then by inserting it toward

Strany 53

TECHNICAL FEATURES 5 5 TECHNICAL FEATURES 5.1 TECHNICAL DATA Datalogic Jet™ Common Features Electrical Features Power DC supply 12 to 14 V ± 5

Strany 54 - 4 MAINTENANCE

DATALOGIC JET™ 5 Mechanical Features Dimensions (LxWxH) 17.6 x 9 x 2.8 cm / 6.9 x 3.5 x 1.1 in Weight (depending on model) 424– 465 g / 14.9–16.4 oz

Strany 55 - MAINTENANCE

TECHNICAL FEATURES 5 Datalogic Jet™ Imager Optical Features Optical Features Max. resolution 1D Codes 0.10 mm / 4 mils 2D Codes 0.17 mm / 6.6 mils

Strany 56 - 4.3 CLEANING THE PDA

3.5.1 LED Status... 20 3.5.2 Status Bar ...

Strany 57 - 5 TECHNICAL FEATURES

DATALOGIC JET™ 5 5.2 READING DIAGRAMS Datalogic Jet™ HP Laser Reading Zones (10° skewl)100 200 400200 100 0 100 200 300 500600700 800 mm300 mm 300 1

Strany 58

TEST CODES 6 6 TEST CODES High Density Codes 0.25 mm (10 mils) Code 39 !17162H! 17162 2/5 Interleaved Ë"8NduÌ 0123456784

Strany 59

DATALOGIC JET™ 6 Medium Density Codes 0.38 mm (15 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code

Strany 60 - 5.2 READING DIAGRAMS

TEST CODES 6 Low Density Codes 0.50 mm (20 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code 128 ÌtestwÎ

Strany 61 - (6450*TRMN(

GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile

Strany 62 - Ë"8NduÌ

EEPROM Electrically Erasable Programmable Read-Only Memory. An on-board non-volatile memory chip. Flash Disk Non-volatile memory for storing applica

Strany 63

RFID (Radio frequency identification) A technology that incorporates the use of electromagnetic or electrostatic coupling in the radio frequency (RF)

Strany 64 - GLOSSARY

INDEX A Accessories; 4 Available Models; 2 B Backup Directory File Management; 37 Bluetooth® Manager Device Setup; 34 Buttons; 28 C Charging the Bat

Strany 65

System Control and Navigation Keys; 17 T Technical Features; 41 Test Codes; 45 U Using the Stylus; 13 W Wireless Communication; 31 52

Strany 66

DATALOGIC S.p.A., 05Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das

Strany 67

DATALOGIC END USER LICENSE AGREEMENT BY DOWNLOADING OR INSTALLING THE SOFTWARE, OR BY USING DATALOGIC EQUIPMENT THAT INCLUDES THIS SOFTWARE, YOU AR

Strany 68

ETSI EN 300 328 v1.6.1, November 2004: ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMI

Strany 69