DX8200A REFERENCE MANUAL
16
3
3 CBX ELECTRICAL CONNECTIONS
Each scanner model has the following connectors:
Scanner Model Connectors
Standard 26-pin male serial interface and I/O connector
17-pin male Lonworks connector
17-pin female Lonworks connector
Ethernet 26-pin male serial interface and I/O connector
17-pin male Lonworks connector
17-pin female Lonworks connector
M12 4-pin D-coded connector for Ethernet *
Profibus 26-pin male serial interface and I/O connector
17-pin male Lonworks connector
17-pin female Lonworks connector
Profibus 9-pin female connector
DeviceNet 26-pin male serial interface and I/O connector
17-pin male Lonworks connector
17-pin female Lonworks connector
DeviceNet 5-pin male connector
* older models have RJ45 Industrial modular connector
All DX8200A models can connect their 26-pin male D-sub connector for connection to the
power supply, serial interface and input/output signals to a CBX connection box by using the
dedicated cables (CAB-F0x).
We recommend making system connections through one of the CBX connection boxes since
they offer the advantages of easy connection, easy device replacement and filtered
reference signals.
NOTE
If you require direct wiring to the scanner the details of the connector pins
and relative connections are indicated in Chaper 4.
For Lonworks network connections see chapters 5 and 7.
For Fieldbus connection
s see chapters 6 and 7.
For ID-NET
™ Fixed Baudrate connections see the Application Note on the CD-ROM.