SOFTWARE CONFIGURATION
109
8
8.4.3 Calibration
VisiSet™ provides a Calibration Tool to maximize the reading performance by tuning the
acquisition parameters and the time of the delayed triggers.
By selecting the Calibration Tool from the VisiSet™ Main Menu (F), the following window
appears together with the Parameter Setup window:
Figure 114 - Calibration OK
This tool provides a "real-time" image display while Matrix 210™ is reading. It also gives
immediate results on the performance of the installed Matrix 210™ reader.
If Self Tuning is enabled, the Calibration Tool window indicates the region where the
calibration algorithm is performed: it is within the central box delimited by four red dots.
NOTE
If using Region Of Interest windowing, some or all of the four red dots
delimiting the calibration algorithm area may be located outside the
VisiSet™ display area (not visible).