MATRIX-2000™Reference Manual

Strany 2

Matrix-2000™ Reference Manual 1 CAUTION If Matrix-2000™ is connected to a C-BOX 3x0/4x0 through its 25-pin connector, then the Matrix-2000™ 9-pin Au

Strany 3 - CONTENTS

RAPID CONFIGURATION 1STEP 3 – AUTOLEARNING CONFIGURATION An autolearning procedure is available to reduce installation time.Status and diagnostic inf

Strany 4

Matrix-2000™ Reference Manual 1 NOTE Autolearning configuration parameters can be saved to temporary memory only by selecting the "Autolearning

Strany 5 - REFERENCES

RAPID CONFIGURATION 1To cancel the Positioning function, press and hold the keypad button at any time during the procedure: the F1 LED will stop blink

Strany 6 - COMPLIANCE

Matrix-2000™ Reference Manual 1 STEP 4 – INSTALLING VISISET™ CONFIGURATION PROGRAM VisiSet™ is a Datalogic reader configuration tool providing sever

Strany 7 - GENERAL VIEW

RAPID CONFIGURATION 1The Autolearning Wizard option is advised for rapid configuration or for new users. It allows reader configuration in a few easy

Strany 8

Matrix-2000™ Reference Manual 1 The reader flashes once acquiring the image and auto determines the best exposure and gain settings. If the code symb

Strany 9 - 1 RAPID CONFIGURATION

RAPID CONFIGURATION 1ADVANCED READER CONFIGURATION For further details on advanced product configuration, refer to the VisiSet™ Help On-Line. The fo

Strany 10 -

Matrix-2000™ Reference Manual 2 2 GENERAL FEATURES 2.1 INTRODUCTION Matrix-2000™ is a Datalogic compact 2D reader designed and produced to be a hi

Strany 11 - Auto Learn

GENERAL FEATURES 22.2 DESCRIPTION Some of the main features of this reader are given below: • Decoding of most popular linear and stacked barcodes,

Strany 12 - Positioning (Optional)

Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Matrix-2000™ Reference Manual Ed.

Strany 13 - Restore Default (Optional)

Matrix-2000™ Reference Manual 2 The following indicators are located on the top of the reader: PWR red LED indicates that the reader is connected t

Strany 14

GENERAL FEATURES 22.3 MODEL DESCRIPTION The Matrix-2000™ reader is available in different versions according to the following characteristics: MATR

Strany 15 - RAPID CONFIGURATION

Matrix-2000™ Reference Manual 2 2.5 APPLICATION EXAMPLES Matrix-2000™ is profitably used in the omnidirectional reading of 2D, stacked, linear and p

Strany 16

GENERAL FEATURES 2Matrix-2000™ assures the reading of deformed and / or overprinted codes, even though damaged or printed on high reflective surfaces

Strany 17 - Alternative Layouts

Matrix-2000™ Reference Manual 2 Figure 17 - Dot Peening Marking on Metal Surface with Multi-dot per Code Element Figure 18 - Directly Marked Dot M

Strany 18 - 2 GENERAL FEATURES

GENERAL FEATURES 22.5.1 External Lighting Systems In some direct part marking applications best reading results are obtained by using an external li

Strany 19 - 2.2 DESCRIPTION

Matrix-2000™ Reference Manual 2 The LT-210 Spot Lighting System provides a high intensity light source designed for the following applications: • wi

Strany 20

GENERAL FEATURES 2The LT-314 45° Dark Field Ring Lighting System is designed for reading codes produced by Dot Peening or Laser Etching on flat, refle

Strany 21 - 2.4 ACCESSORIES

Matrix-2000™ Reference Manual 2 The LT-410 Coaxial Lighting System is an axial diffuse illuminator designed for reading codes produced by Dot Peening

Strany 22 - 2.5 APPLICATION EXAMPLES

GENERAL FEATURES 2The LT-511 Dome Lighting System is a diffuse dome light designed for reading printed label or Direct Marking codes on parts with a c

Strany 23 - GENERAL FEATURES

CONTENTS REFERENCES ...v Conventions...

Strany 24

Matrix-2000™ Reference Manual 3 3 INSTALLATION 3.1 PACKAGE CONTENTS Verify that the Matrix-2000™ reader and all the parts supplied with the equipm

Strany 25

INSTALLATION 33.2 MECHANICAL INSTALLATION Matrix-2000™ can be installed to operate in different positions. The eight screw holes (M4 x 5) on the body

Strany 26

Matrix-2000™ Reference Manual 3 73 [2.87]121 [4.76]57 [2.24]mm[inch] 73 [2.87]Ø4.2 [Ø0.17]15 [0.59]37 [1.46]4.2 [0.17]95 [3.74]47.5 [1.87]Ø8.2 [Ø0.3

Strany 27

INSTALLATION 33.2.1 Mounting Matrix-2000™ Using the Matrix-2000™ mounting bracket you can obtain vertical shift and rotation of the reader as shown i

Strany 28

Matrix-2000™ Reference Manual 3 3.3 ELECTRICAL CONNECTIONS The Matrix-2000™ reader is equipped with a 25-pin male D-Sub connector for connection to

Strany 29

INSTALLATION 3There is also a separate 9-pin female D-sub connector for the Auxiliary port connection with the following pinout: 5196 Figure 37 - 9-

Strany 30 - 3 INSTALLATION

Matrix-2000™ Reference Manual 3 C-BOX 100 Pinout for Matrix-2000™ The table below gives the pinout of the C-BOX 100 terminal block connectors. Use t

Strany 31 - 3.2 MECHANICAL INSTALLATION

INSTALLATION 33.3.1 Power Supply Power is supplied to the reader through the pins provided on the 25-pin connector (see Figure 39): MATRIX9/1323/2

Strany 32

Matrix-2000™ Reference Manual 3 3.3.2 Main Serial Interface The signals relative to the following serial interface types are available on the 25-pin

Strany 33 - 3.2.1 Mounting Matrix-2000™

INSTALLATION 3 MATRIX7 4 5 3 GND_ISORTS232CTS232RX232TX2322 USER INTERFACE Reference Ground HandshakingSignals TXD RXD Earth Ground 1 SHIELD Figure 40

Strany 34 - 3.3 ELECTRICAL CONNECTIONS

4.2 Installing VisiSet™...50 4.3 Startup ...

Strany 35

Matrix-2000™ Reference Manual 3 RS485 Full-Duplex Interface The opto-isolated RS485 full-duplex (5 wires + shield) interface can be used for non-pol

Strany 36

INSTALLATION 3RS485 Half-Duplex Interface The opto-isolated RS485 half-duplex (3 wires + shield) interface is available for polled communication prot

Strany 37 - 3.3.1 Power Supply

Matrix-2000™ Reference Manual 3 The figure below shows a multidrop configuration with Matrix-2000™ readers connected to a Multiplexer. # 1 # 0 max

Strany 38 - RS232 Interface

INSTALLATION 33.3.3 Auxiliary RS232 Interface The RS232 auxiliary interface is available for Point-to-Point, Pass Through or Master/Slave connections

Strany 39 - INSTALLATION

Matrix-2000™ Reference Manual 3 3.3.4 Ethernet Interface (Matrix-21XX models only) The Ethernet Interface can be used for TCP/IP communication with

Strany 40 - RS485 Full-Duplex Interface

INSTALLATION 33.3.5 Inputs Two opto-coupled and polarity insensitive inputs are available on the 25-pin connector. The pinout is the following: Pin

Strany 41 - RS485 Half-Duplex Interface

Matrix-2000™ Reference Manual 3 USER INTERFACEVSMATRIX AVext BV+VCC ~~+-GND OUT 30 Vdc Max. Figure 51 - Input NPN Command Using External Power USER

Strany 42 - RS485REF

INSTALLATION 3MATRIXUSER INTERFACEVext30 Vdc max+-I LoadV Out Figure 53 - Open Collector Output Connection The electrical features of the three outp

Strany 43

Matrix-2000™ Reference Manual 3 3.4 USER INTERFACE RS232 PC-side connections 15 9 6 9-pin male connector 13 25141 25-pin male connector Pin Nam

Strany 44 - Figure 48 - Crossover Cable

INSTALLATION 33.5 POSITIONING Position the reader so that the distance from the reading window to the code surface is that indicated in the figure be

Strany 45 - 3.3.5 Inputs

REFERENCES CONVENTIONS This manual uses the following conventions: "User" refers to anyone using a Matrix-2000™ reader. "Reader&qu

Strany 46 - 3.3.6 Outputs

Matrix-2000™ Reference Manual 3 (2.56 x 2.05 in)2X25 HD MP(5.31 in)focus distance135 mmcode surface65 x 52 mmFOV 2X45 LD MP(4.72 x 3.78 in)focus dis

Strany 47

INSTALLATION 3Matrix-2000™ is able to decode code labels at a variety of angles, however significant angular distortion may degrade reading performanc

Strany 48 - 3.4 USER INTERFACE

Matrix-2000™ Reference Manual 3 3.6 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. However, they also requir

Strany 49

INSTALLATION 33.6.2 Multiplexer Each reader is connected to a MX4000 through a multidrop network. Before proceeding with the connection it is necessa

Strany 50 - 2X45 LD MP

Matrix-2000™ Reference Manual 3 3.6.3 RS232 Master/Slave The RS232 Master/Slave connection is used to collect data from several readers to build eit

Strany 51

INSTALLATION 33.6.4 Pass Through Pass through mode allows two or more readers to be connected to a single external serial interface. Each reader tra

Strany 52 - 3.6.1 Point-to-Point

Matrix-2000™ Reference Manual 3 3.6.5 Ethernet Connection (Matrix-21XX models only) The Matrix-21XX Ethernet connection is possible in two differen

Strany 53 - 3.6.2 Multiplexer

INSTALLATION 3When using a Local Area Network (LAN), one or more Matrix-21XXs can be connected to the network by using straight through cables: P.S

Strany 54 - 3.6.3 RS232 Master/Slave

Matrix-2000™ Reference Manual 4 4 SOFTWARE CONFIGURATION Software configuration of your Matrix-2000™ for static reading or simple code reading appl

Strany 55 - 3.6.4 Pass Through

SOFTWARE CONFIGURATION 44.3 STARTUP After completing the mechanical and electrical connections to Matrix-2000™, you can begin software configuration a

Strany 56 - External Trigger

COMPLIANCE For installation, use and maintenance it is not necessary to open the reader. EMC COMPLIANCE In order to meet the EMC requirements: •

Strany 57

Matrix-2000™ Reference Manual 4 4.3.1 VisiSet™ Options The Options item from the VisiSet™ menu (see Figure 66) presents a window allowing you to con

Strany 58 - 4 SOFTWARE CONFIGURATION

SOFTWARE CONFIGURATION 4 Figure 69 - Options – Communication: Serial Port Figure 70 - Options – Communication: Ethernet 53

Strany 59 - 4.3 STARTUP

Matrix-2000™ Reference Manual 4 4.4 CONFIGURATION Once connected to Matrix-2000™ as described in par. 4.3, you can modify the configuration paramete

Strany 60 - 4.3.1 VisiSet™ Options

SOFTWARE CONFIGURATION 44.4.1 Edit Reader Parameters The Parameter Setup window displays the configuration parameters grouped in a series of folders

Strany 61 - SOFTWARE CONFIGURATION

Matrix-2000™ Reference Manual 4 Parameters to verify/modify:  Operating Mode Sets the parameters which customize the reader operating mode startin

Strany 62 - 4.4 CONFIGURATION

SOFTWARE CONFIGURATION 4When all the configuration parameters are set correctly, save them to the Matrix-2000™ reader by pressing the Send button. See

Strany 63

Matrix-2000™ Reference Manual 4 4.4.2 Calibration VisiSet™ provides a Calibration Tool to maximize the reading performance by tuning the acquisition

Strany 64

SOFTWARE CONFIGURATION 4The following examples show some of the typical conditions occurring during the installation: Under-exposure: To correct this

Strany 65

Matrix-2000™ Reference Manual 4 Over-exposure: To correct this result it is recommended to change the following parameters in their order of appearan

Strany 66 - 4.4.2 Calibration

SOFTWARE CONFIGURATION 4Moving code out of the Field of View: To correct this result and have the code completely visible in F.O.V., it is possible to

Strany 67

GENERAL VIEW Matrix-2000™ 1 6 7 8 2 345 9 121110 Figure A Reading Window F2 LED F1 LED Power On LED Keypad button 1 2 4 5 3 6 987Ex

Strany 68

Matrix-2000™ Reference Manual 4 4.5 IMAGE CAPTURE AND DECODING By using the Capture Image and Decode Last Image functions from the VisiSet™ Main me

Strany 69

MAINTENANCE 55 MAINTENANCE 5.1 CLEANING Clean the reading window (see Figure A, 1) periodically for continued correct operation of the reader. Dus

Strany 70 - 4.6 STATISTICS

Matrix-2000™ Reference Manual 6 6 TROUBLESHOOTING 6.1 GENERAL GUIDELINES • When wiring the device, pay careful attention to the pin number of the

Strany 71 - 5 MAINTENANCE

TROUBLESHOOTING 6TROUBLESHOOTING GUIDE Problem Suggestion One Shot or Phase Mode using the External Trigger input: the ”TRIG” LED is not blinking whi

Strany 72 - 6 TROUBLESHOOTING

Matrix-2000™ Reference Manual 6 TROUBLESHOOTING GUIDE Problem Suggestion Reading: the reader always transmits the No Read Message • Run the Auto Lea

Strany 73

TECHNICAL FEATURES 77 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply Voltage 10 to 30 Vdc Power Consumption 8 W max.; 5 W typical Communi

Strany 74

Matrix-2000™ Reference Manual 7 ENVIRONMENTAL FEATURES Operating Temperature 0 to 40 °C (32 to 104 °F) Storage Temperature -20 to 70 °C (-4 to 158 °

Strany 75 - 7 TECHNICAL FEATURES

GLOSSARY AS9132 Standard defining uniform quality and technical requirements for direct part marking (DPM) using Data Matrix symbologies. Barcodes

Strany 76

EEPROM Electrically Erasable Programmable Read-Only Memory. An on-board non-volatile memory chip. Element The basic unit of data encoding in a 1D or

Strany 77 - GLOSSARY

Multidrop A communication protocol for connecting two or more readers in a network with a concentrator (or controller) and characterized by the use o

Strany 79

INDEX A Accessories; 13 Application Examples; 14 Auto Learn; 3 Auxiliary RS232 Interface; 35 C Calibration; 58 C-BOX Pinout for Matrix-2000™; 28 Com

Strany 80

DECLARATION OF CONFORMITY 07Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that

Strany 81 - DECLARATION OF CONFORMITY

www.automation.datalogic.com

Strany 82

RAPID CONFIGURATION 11 RAPID CONFIGURATION STEP 1 – CONNECTING THE SYSTEM To connect the system in a Stand Alone configuration, you need the hardwa