Strany 1 - MATRIX 400™

MATRIX 400™Code Quality Verifier Solution Manual

Strany 2

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 AS9132A AND AIM DPM VERIFICATION: To install the Matrix 400™ reader in an AS9132A or AIM DPM symbol ve

Strany 3 - CONTENTS

RAPID CONFIGURATION 1 REQUIRED ACCESSORIES: Item Accessory Description Order No. Matrix 400-x00-0x0 Reader 1 LNS-1116 16 mm C-Mount Lens (Recomm

Strany 4

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 STEP 2 – CONNECT THE SYSTEM To install the Matrix 400™ reader in a symbol verifier system configuration

Strany 5 - REFERENCES

RAPID CONFIGURATION 1 AS9132A AND AIM DPM VERIFICATION: PG 6000 CAB-MS01 CBXMain InterfaceHost Matrix 400™ BK-4410 LT-410 Code Surface Figure 4 –

Strany 6 - COMPLIANCE

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 CBX100/CBX500 PINOUT FOR MATRIX 400™ The table below gives the pinout of the CBX100/CBX500 terminal bl

Strany 7 - GENERAL VIEW

RAPID CONFIGURATION 1STEP 3 – MOUNT AND POSITION THE SYSTEM 1. To mount the Matrix 400™, use the mounting brackets to obtain the most suitable posit

Strany 8

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 3. The BK-4990 bracket comes already partially mounted (D+A) with 2 M4 screws. 4. Mount the bracket A

Strany 9 - 1 RAPID CONFIGURATION

RAPID CONFIGURATION 1 Steps 3 to 10 can be repeated to mount the LT-410 Coaxial Lighting System: C D BA 3. The BK-4410 bracket comes already part

Strany 10

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 9. After Focusing, tighten the Focus and Diaphragm Locking Knobs. 10. Swing the bracket D 90° as previ

Strany 11

RAPID CONFIGURATION 1STEP 4 – INSTALLING VISISET™ CONFIGURATION PROGRAM VisiSet™ is a Datalogic reader configuration tool providing several important

Strany 12 - STEP 2 – CONNECT THE SYSTEM

Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Matrix 400™ Code Quality Verifier

Strany 13

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 STEP 5 – FOCUS THE READER AND CALIBRATE IMAGE DENSITY The Autolearning Wizard option is advised for rap

Strany 14

RAPID CONFIGURATION 1 4. Press the "Positioning" button. The reader continuously acquires images and gives visual feedback in the view imag

Strany 15 - RAPID CONFIGURATION

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 8. Rotate the Focusing ring on the lens to obtain the maximum value for the Focus Quality Index and th

Strany 16

RAPID CONFIGURATION 1STEP 6 – SETTING VERIFICATION PARAMETERS Before to calibrate and validate your verifier system, you need to set the parameters f

Strany 17

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 5. Select the “Options” button from the Symbol Verification window. 2 The Symbol Verification Optio

Strany 18

RAPID CONFIGURATION 1STEP 7 – CALIBRATE VERIFIER SYSTEM The Verifier Setup option allows system configuration and calibration in a few easy steps. 1

Strany 19

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 4. Press the “Positioning” button. The reader continuously acquires images and gives visual feedback i

Strany 20

RAPID CONFIGURATION 1 6. Use the spin boxes in the Reflectance Calibration Options section to set the Minimum and Maximum Reflectance (%) values prov

Strany 21

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 4. Press the "Positioning" button. The reader continuously acquires images and gives visual

Strany 22

RAPID CONFIGURATION 1STEP 8 – VALIDATE VERIFIER SYSTEM Once the verifier system is calibrated, the Verifier Setup option can be used to evaluate its

Strany 23

CONTENTS REFERENCES ...v Conventions...

Strany 24

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 4. Press the "Positioning" button. The reader continuously acquires images and gives visual

Strany 25

RAPID CONFIGURATION 1 Repeat steps 3 and 4 rotating clockwise the symbol of approximately 72°, 144°, 216° and 288° in order to achieve a full 360° rot

Strany 26

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 STEP 9 – VERIFY SYMBOL When the system is configured and calibrated, you can move again to the Symbol V

Strany 27

RAPID CONFIGURATION 1 Press the “Positioning” button again to stop positioning. 2 9. Press the “Capture Image” button. The reader flashes once to a

Strany 28

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 1 STEP 10 – SAVE VERIFICATION REPORT The Symbol Verification window allows to generate and save a report

Strany 29

RAPID CONFIGURATION 1 Code data and symbology Non-graded parameters (Pixelsper Element, Print Growth, ..) Acquired code image Reference Data (Reader

Strany 30

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 2 2 SYMBOL VERIFICATION OVERVIEW 2.1 INTRODUCTION Matrix 400™ can be used to evaluate printed or mark

Strany 31

SYMBOL VERIFICATION OVERVIEW 22.2 ISO/IEC 15415 2D STANDARD The ISO-IEC 15415 Standard specifies the methodologies for the measurement of specific a

Strany 32 - STEP 9 – VERIFY SYMBOL

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 2 Axial Non-Uniformity (ANU) Measures and grades the squareness of all modules in the direction of each

Strany 33

SYMBOL VERIFICATION OVERVIEW 2 Modulation (MOD) Modulation is a measure of the uniformity of reflectance of the dark and light modules respectively. S

Strany 34

5.4 Configuration ...59 5.4.1 ISO/IEC 15

Strany 35

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 2 Unused Error Correction (UEC) This parameter tests and grade the extent to which regional or spot dama

Strany 36 - 2.1 INTRODUCTION

SYMBOL VERIFICATION OVERVIEW 22.3 AS9132 2D STANDARD This SAE Aerospace Standard (AS) defines uniform Quality and Technical requirements relative to

Strany 37 - SYMBOL VERIFICATION OVERVIEW

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 2 Dot Ovality Evaluate the ovality of each dot by measuring the difference between its height (D) and wi

Strany 38

SYMBOL VERIFICATION OVERVIEW 22.4 AIM DPM QUALITY GUIDELINE The AIM DPM Quality Guideline is applicable to the symbol quality assessment of direct p

Strany 39

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 2 Axial Non-Uniformity (ANU) Measures and grades the squareness of all modules in the direction of each

Strany 40

SYMBOL VERIFICATION OVERVIEW 2 Grid Non-Uniformity (GNU) qualifies the module placement by comparing to a nominal evenly spaced grid.

Strany 41 - 2.3 AS9132 2D STANDARD

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 2 2.5 ISO/IEC 15416 1D STANDARD The ISO-IEC 15416 Standard specifies the methodologies for the measurem

Strany 42

SYMBOL VERIFICATION OVERVIEW 2 Decode The symbology reference decode algorithm shall be used to decode the symbol using the element e

Strany 43

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 2 Defects are irregularities found within elements and quiet zones, and are measured in terms of element

Strany 44

SYMBOL VERIFICATION OVERVIEW 2 ISO/IEC 16022-18004ISO/IEC 15415 AIM DPM AS9132A Angle Of Distortion 3 Axial Non Uniformity 3 3 3 Cell Co

Strany 45

REFERENCES CONVENTIONS This manual uses the following conventions: "User" refers to anyone using a Matrix 400™ reader. "Reader&quo

Strany 46

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 3 3 READING FEATURES 3.1 OPTICAL ACCESSORY SELECTION Referring to Figure 12 and the formula below, use

Strany 47

READING FEATURES 3Example: The FOV for a Matrix 400 600-0x0 base using the 16 mm lens at a focus distance of 200 mm is: FOVH = 2 [(200 mm + 35 mm) t

Strany 48

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 3 3.2.2 1D (Linear) Codes 1D Codes – Matrix 400 400-0x0 (SXGA) 16 mm 010203040506070809010050 60 70 80

Strany 49

READING FEATURES 33.2.3 2D (Bi-dimensional) Codes 2D Codes – Matrix 400 400-0x0 (SXGA) 16 mm 010203040506070809010050 60 70 80 90 100 110 120 130 14

Strany 50 - 3 READING FEATURES

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 4 EXTERNAL LIGHTING SYSTEMS 4.1 INTRODUCTION A series of accessory illuminators are available which

Strany 51 - READING FEATURES

SOFTWARE CONFIGURATION 46 The LT-210 Mini Spot Lighting System provides a high intensity light source designed for the following applications: • wi

Strany 52 - 3.2.2 1D (Linear) Codes

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 The LT-316 60° Dark Field Ring Lighting System is designed for reading codes produced by Dot Peening (e

Strany 53 - Horizontal FOV (mm)

SOFTWARE CONFIGURATION 46 The LT-511 Dome Lighting System is a diffuse dome light designed for reading printed label or Direct Marking codes on parts

Strany 54 - 4 EXTERNAL LIGHTING SYSTEMS

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 4.2 HOW TO SELECT THE RIGHT EXTERNAL LIGHTING SYSTEM 50

Strany 55 - SOFTWARE CONFIGURATION

SOFTWARE CONFIGURATION 465 SOFTWARE CONFIGURATION Software configuration of your Matrix 400™ for code quality verification applications can be acco

Strany 56

COMPLIANCE For installation, use and maintenance it is not necessary to open the reader. EMC COMPLIANCE In order to meet the EMC requirements: •

Strany 57

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 5.3 STARTUP After completing the mechanical and electrical connections to Matrix 400™, you can begin s

Strany 58

SOFTWARE CONFIGURATION 465.3.1 VisiSet™ Options The Options item from the VisiSet™ menu (see Figure 23) presents a window allowing you to configure:

Strany 59 - 5 SOFTWARE CONFIGURATION

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 The Communication folder allows choosing between Serial ports or Ethernet as communication channels.

Strany 60 - 5.3 STARTUP

SOFTWARE CONFIGURATION 465.3.2 Edit Reader Parameters The Parameter Setup window displays the configuration parameters grouped in a series of folde

Strany 61 - 5.3.1 VisiSet™ Options

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 Parameters to verify/modify:  Operating Mode Sets the parameters which customize the reader operati

Strany 62

SOFTWARE CONFIGURATION 465.3.3 Send Configuration Options The device parameters are divided into two main classes, Configuration and Environmental

Strany 63

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 For device replacement it is necessary to send the previously saved configuration (both Configuration

Strany 64

SOFTWARE CONFIGURATION 465.4 CONFIGURATION Once connected to Matrix 400™ as described in paragraph 5.3, you can modify the configuration parameters

Strany 65

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 5.4.2 ISO/IEC 15416 Verification Setup Allows to configure lighting and camera settings to comply wit

Strany 66

SOFTWARE CONFIGURATION 465.4.3 AS9132A Verification Setup Allows to configure camera settings to comply with AS9132A requirements for 2D symbol veri

Strany 67 - 5.4 CONFIGURATION

GENERAL VIEW Matrix 400™ Figure A 2 7 10 9 8 6 1 2 3 4 5 2 1 2 3 4 987Device Class Label Mounting Holes (12) Lens Cover Lens (separate ac

Strany 68

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 5.4.4 AIM DPM Verification Setup Allows to configure lighting and camera settings to comply with AIM

Strany 69

SOFTWARE CONFIGURATION 465.4.5 Digital Outputs Activation Matrix 400™ digital outputs can be used to indicate if one or more grades of the decoded

Strany 70

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 The valid Activation Events for this standard are: • ISO-IEC Symbol Contrast • ISO-IEC Modulation •

Strany 71

SOFTWARE CONFIGURATION 465.4.6 Code Filtering Matrix 400™ digital outputs allows ordering read codes and filtering them according to their symbology

Strany 72 - • AS9132 Dot Ovality

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 • ISO-IEC Modulation • ISO-IEC Min Edge Contrast • ISO-IEC Decodability • ISO-IEC / AIM DPM Minimu

Strany 73 - 5.4.6 Code Filtering

SOFTWARE CONFIGURATION 465.4.7 Output Message Format Matrix 400™ allows to include in the output data string information about the code quality para

Strany 74

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 You can also include information about the code quality parameters calculated according to the followi

Strany 75 - 5.4.7 Output Message Format

SOFTWARE CONFIGURATION 46 Example: to have a Data Packet composed of Code Data followed by the ISO/IEC 15415 code quality parameters (grade only) in

Strany 76

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 4 When ISO/IEC 15416 Status parameter is enabled, the following code quality parameters can be included

Strany 77

SOFTWARE CONFIGURATION 46 • %t AS9132 Angle Of Distortion (grade) • %y AS9132 Angle Of Distortion (value) • %z AS9132 Quiet Zone (grade) • %0 AS9

Strany 79

MATRIX 400™ CODE QUALITY VERIFIER SOLUTION 6 6 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply Voltage 10 to 30 Vdc Power Consumption 0.8 t

Strany 80 - 6 TECHNICAL FEATURES

TECHNICAL FEATURES 6 SOFTWARE FEATURES Readable Code Symbologies 1-D and stacked 2-D POSTAL • PDF417 Standard • Micro PDF417 • Code 128 (EAN 128

Strany 81 - TECHNICAL FEATURES

GLOSSARY AIM (Association for Automatic Identification and Mobility): AIM Global is the international trade association representing automatic iden

Strany 82 - GLOSSARY

Depth of Field The difference between the minimum and the maximum distance of the object in the field of view that appears to be in focus. Diffused

Strany 83

LED (Light Emitting Diode) A low power electronic light source commonly used as an indicator light. It uses less power than an incandescent light bu

Strany 84

DECLARATION OF CONFORMITY 07Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that

Strany 85 - DECLARATION OF CONFORMITY

www.automation.datalogic.com

Strany 86

RAPID CONFIGURATION 11 RAPID CONFIGURATION STEP 1 – CHECK REQUIRED HARDWARE ISO/IEC 15415 AND ISO/IEC 15416 VERIFICATION To install the Matrix 400

Komentáře k této Příručce

Žádné komentáře