LT-300 RING
LIGHTING SYSTEM
FOR MATRIX FAMILY READERS
DESCRIPTION
The LT-300 Ring Lighting System is designed for reading codes
produced by Dot Peening or Laser Etching on flat, reflective parts and
particularly in applications where reading is performed from
underneath. It provides a very uniform light source on a wide area.
MECHANICAL DIMENSIONS
149
[5.87]
15
[0.59]
27.7
[1.09]
Ø99
[Ø3.90]
WIRING
Wire Color CBX/Matrix Signal Meaning
Brown Vdc 10 to 30 Vdc
Black GND Ground
Yellow Green Earth Earth Ground
Blue O1-, O2-, (O3-) Control Signal -
White O1+, O2+, (O3+) Control Signal +
CAUTION
The LT-300 control signals must always be
connected to one of the Matrix Digital Output
signals. In VisiSet™, set the relative Output Line
Function parameter to "External Lighting System" and
the Matrix Output x External Lighting System Mode
parameter to "Triggered".
PACKAGE CONTENTS
The LT-300 package contains the following items:
LT-300 Ring Lighting System with adapter bracket
(2) Mounting brackets (for Matrix-2000 90º Reading Window
models only)
(4) M2.5 countersunk screws for Matrix-1000/2000™ Direct
Window bracket mounting to ring
(4) M4 screws for bracket mounting to reader
(4+4) M2.5 locking and flat washers for bracket mounting to LT-
300 Ring
LT-300 Ring – CBX connecting Cable
Instruction Manual
90° READING WINDOW MOUNTING Matrix-1000/2000™
NOTE
For this application, the adapter bracket must be
removed from the LT-300 Ring before mounting the
90° brackets. Reuse the 4 M2.5 screws for mounting.
1. Mount the two brackets A onto the LT-300 lighting ring B re-using
the 4 M2.5 screws and the washers in the package.
2. Mount the reader C onto the lighting ring assembly aligning it
correctly to the holes. Use the 4 M4 screws in the package.
3. Insert the cable plug into the ring’s connector, correctly observing
the positioning key, and then lock it safely by tightening the
threaded locking ring.
4. Wire the LT-300 to the CBX according to the Wiring table.
5. Position the Matrix assembly over the code reading area at the
correct Focus Distance for your model, (described in the Matrix
Reference Manual under "Reading Features").
DIRECT READING WINDOW MOUNTING Matrix-1000/2000™
The following parts are required for mounting:
LT-300 Ring Lighting System
BK-510 Bracket
1. Mount the BK-510 bracket A onto the LT-300 Ring adapter bracket
B using the 4 M2.5 screws and the washers in the package.
2. Mount the reader C onto the lighting ring assembly through the
positioning slots on the brackets. Use the 4 M4 screws in the
package.
3. Insert the cable plug into the ring’s connector, correctly observing
the positioning key, and then lock it safely by tightening the
threaded locking ring.
4. Wire the LT-300 to the CBX according to the Wiring table.
5. Position the Matrix assembly over the code reading area at the
correct Focus Distance for your model, (described in the Matrix
Reference Manual under "Reading Features").
mm
[inch]
C
A
B
C
A
B
Zobrazit stránku 0
1 2

Shrnutí obsahu

Strany 1 - FOR MATRIX FAMILY READERS

LT-300 RING LIGHTING SYSTEM FOR MATRIX FAMILY READERS DESCRIPTION The LT-300 Ring Lighting System is designed for reading codes produced by Dot

Strany 2

POSITIONING Matrix-1000/2000™ code surface Focus distance = α + β For 90° reading window applications, position the Matrix assembly over the co

Komentáře k této Příručce

Žádné komentáře