Datalogic Controller SC6000 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Síťové přepínače Datalogic Controller SC6000. SC6000 Host Mode Programming (, 580249 byte) Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Host Mode Programming

SC6000Host Mode Programming

Strany 2

SC6000 HOST MODE PROGRAMMING 6 2 HOST DEVICE <ESC> d M <B0H> 0 (Exit Programming Mode)<ESC> d <CR><LF> <ESC>

Strany 3 - CONTENTS

PROGRAMMING STRINGS 7 33 PROGRAMMING STRINGS 3.1 DEFINITIONS Common definitions for each parameter are: Path The complete parameter path must hav

Strany 4

SC6000 HOST MODE PROGRAMMING 8 3 Type (Parameter Type) Parameter type is essential in order to decide the parameter VALUE format used in the progra

Strany 5 - 1 HOST MODE PROGRAMMING

PROGRAMMING STRINGS 9 3String (Type = 2) Length Minimum and maximum number of characters allowed for this parameter. Example: Device Name parameter

Strany 6 - 2 PROGRAMMING COMMANDS

SC6000 HOST MODE PROGRAMMING 10 3 Floating Point (Type = 4) The Floating Point parameter value has the following format: XXX.YYY Range Minimum a

Strany 7 - PROGRAMMING COMMANDS

PROGRAMMING STRINGS 11 33.2 HOW TO SEND SINGLE PARAMETER TO THE READER NOTE To guarantee the complete compatibility with future software releases,

Strany 8 - 2.3 SELF DISCONNECTION

SC6000 HOST MODE PROGRAMMING 12 3 Using Short Parameter Description (Shortcut) The 'Set Shortcut' programming string (based on the short

Strany 9

PROGRAMMING STRINGS 13 33.3 HOW TO GET SINGLE PARAMETER FROM THE READER NOTE To guarantee the complete compatibility with future software releases

Strany 10 - SC6000 HOST MODE PROGRAMMING

SC6000 HOST MODE PROGRAMMING 14 3 Using Short Parameter Description (Shortcut) The 'Get Shortcut' programming string (based on the short

Strany 11 - 3 PROGRAMMING STRINGS

PROGRAMMING STRINGS 15 33.4 HOW TO ACCESS INSTALLER PARAMETERS Set Right Parameter Description The 'Set Right' programming string allow

Strany 12 - Enumeration (Type = 1)

Datalogic Automation Srl Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy SC6000 Host Mode Programming Ed.: 10/2012 This manu

Strany 13 - Binary String (Type = 3)

SC6000 HOST MODE PROGRAMMING 16 3 3.5 SAVE AND RESTORE COMMANDS The 'Data Storage' programming command must have the following format:

Strany 14 - Floating Point (Type = 4)

PROGRAMMING STRINGS 17 3The 'Restore Default Configuration' programming command must have the following format: SD<space>DEFNUM<C

Strany 15 - PROGRAMMING STRINGS

SC6000 HOST MODE PROGRAMMING 18 3 HOST DEVICE SP<space>PATH1:VALUE1<CR><LF>(Set parameter 1) Y<space>VALUE1<CR><

Strany 16

PROGRAMMING STRINGS 19 33.6 EXAMPLES - 1 - Set Minimum Label Length parameter in CODE LABEL SETTING #2 folder: Path: /Codes/Code#2/MinLength Shortc

Strany 17

SC6000 HOST MODE PROGRAMMING 20 3 - 3 - Set Device Name parameter in USER INFORMATION SECTION folder: Path: /UserInfo/Name Shortcut: 522 Type: 2 (

Strany 18

PROGRAMMING STRINGS 21 3- 5 - Get value of Digital Output 3 Activation Event parameter in DIGITAL OUTPUT LINES folder: Path: /IO/Out/Out2/Active Sho

Strany 19

SC6000 HOST MODE PROGRAMMING 22 4 4 PARAMETERS LIST 4.1 CODE DEFINITION PARAMETER COMPLETE PATH SHC PT VALUE CODE DEFINITION Code Combination /

Strany 20

PARAMETERS LIST 23 4PARAMETER COMPLETE PATH SHC PT VALUE Max Number of Different Characters /Codes/Filters /ContainedFilter NumberOfChar - 0 Range:

Strany 21

SC6000 HOST MODE PROGRAMMING 24 4 PARAMETER COMPLETE PATH SHC PT VALUE Code Symbology /Codes /Code#N /Type 2 1 0 = Code 128 1 = Interleaved 2 of

Strany 22

PARAMETERS LIST 25 4PARAMETER COMPLETE PATH SHC PT VALUE Max Code Position /Codes /Code#N /MaxCodePos 263 0 Range: 0 to 255 Check Digit /Codes /C

Strany 23 - 3.6 EXAMPLES

iii CONTENTS 1 HOST MODE PROGRAMMING...1 2 PROGRAMMING COMMANDS

Strany 24

SC6000 HOST MODE PROGRAMMING 26 4 PARAMETER COMPLETE PATH SHC PT VALUE Serial Stop String /Operating /SerialStop 87 3 Length: 1 to 32 Stop Inpu

Strany 25

PARAMETERS LIST 27 4PARAMETER COMPLETE PATH SHC PT VALUE Minimum Pack Length (mm) /Operating /PktrMinLen 209 0 Range: 50 to 1000 Window Dimension

Strany 26 - 4 PARAMETERS LIST

SC6000 HOST MODE PROGRAMMING 28 4 PARAMETER COMPLETE PATH SHC PT VALUE Max. Consecutive Delayed Codes For Node /Operating /ContEncMaxDelayOf Code

Strany 27 - PARAMETERS LIST

PARAMETERS LIST 29 4PARAMETER COMPLETE PATH SHC PT VALUE Use Aux Serial Port /Operating /ProtocolIndexParameters /AuxPar/AuxEn - 1 0 = Disable 1

Strany 28

SC6000 HOST MODE PROGRAMMING 30 4 PARAMETER COMPLETE PATH SHC PT VALUE Protocol Index Request Message /Operating /ProtocolIndexParameters /MainPar

Strany 29 - 4.2 OPERATING MODES

PARAMETERS LIST 31 4PARAMETER COMPLETE PATH SHC PT VALUE Terminator /Operating /ProtocolIndexParameters /Eth1/PIUserSocket#N /StpSock - 3 Length:

Strany 30

SC6000 HOST MODE PROGRAMMING 32 4 PARAMETER COMPLETE PATH SHC PT VALUE Protocol Index Request Message /Operating /ProtocolIndexParameters /Eth2/PI

Strany 31

PARAMETERS LIST 33 4PARAMETER COMPLETE PATH SHC PT VALUE Field Separator /Operating/NVSHS/NVSRI /NVSFS - 3 Length: 0 to 1 Global Header /Operati

Strany 32

SC6000 HOST MODE PROGRAMMING 34 4 PARAMETER COMPLETE PATH SHC PT VALUE Number of RFID Antennas /Operating/RBSHS /RBSNBSlaves - 0 Range: 0 to 4 S

Strany 33

PARAMETERS LIST 35 44.3 READING SYSTEM LAYOUT PARAMETER COMPLETE PATH SHC PT VALUE READING SYSTEM LAYOUT Device Assignment /Layout/DevAssO 196 1

Strany 35

SC6000 HOST MODE PROGRAMMING 36 4 PARAMETER COMPLETE PATH SHC PT VALUE EAN/UPC ADD ON 5 /Layout/SlvPar/CodPar /AddOn5 149 1 0 = Disable 1 = Enabl

Strany 36

PARAMETERS LIST 37 4PARAMETER COMPLETE PATH SHC PT VALUE Decoding Severity /Layout/SlvPar/CodPar /Code93Par/DecSev 172 0 Range: 1 to 5 Ink Spread

Strany 37

SC6000 HOST MODE PROGRAMMING 38 4 PARAMETER COMPLETE PATH SHC PT VALUE LONWORKS SINGLE SLAVES PARAMETERS (for backward compatibility) SLAVE NUMBER

Strany 38

PARAMETERS LIST 39 44.4 DATA COMMUNICATION SETTING PARAMETER COMPLETE PATH SHC PT VALUE DATA COMMUNICATION SETTING Host Application Protocol Type /

Strany 39 - 4.3 READING SYSTEM LAYOUT

SC6000 HOST MODE PROGRAMMING 40 4 PARAMETER COMPLETE PATH SHC PT VALUE Code EAN 13 Identifier String Comms/OutForm /codIDStr/codEAN13 404 3 Leng

Strany 40

PARAMETERS LIST 41 4PARAMETER COMPLETE PATH SHC PT VALUE Termination String /Comms/OutForm /Standard/Terminator 7 3 Length: 0 to 128 Data Packet

Strany 41

SC6000 HOST MODE PROGRAMMING 42 4 PARAMETER COMPLETE PATH SHC PT VALUE Termination String /Comms/CargoPar /Terminator - 3 Length: 0 to 128 S/W

Strany 42 - /Layout/SngSlv/Slave#N

PARAMETERS LIST 43 4PARAMETER COMPLETE PATH SHC PT VALUE Diagnostic Data On Modem Serial Channel /Comms/CargoPar /OutMsg/DiagSerModem - 1 0 = Disa

Strany 43

SC6000 HOST MODE PROGRAMMING 44 4 PARAMETER COMPLETE PATH SHC PT VALUE Including codes that start with '421…' /Comms/CargoPar /CarCodes

Strany 44

PARAMETERS LIST 45 4PARAMETER COMPLETE PATH SHC PT VALUE MAIN SERIAL PORT Data Tx /Comms/SerMain /SerMain 510 1 0 = Disable 1 = Enable Heartbeat

Strany 45

HOST MODE PROGRAMMING 1 11 HOST MODE PROGRAMMING An alternative method of programming the SC6000 Controller is by sending programming strings. Th

Strany 46

SC6000 HOST MODE PROGRAMMING 46 4 PARAMETER COMPLETE PATH SHC PT VALUE Header n. 10 (Siemens RK512) /Comms/SerMain /Line/SRKHead10 - 3 Length: 1 F

Strany 47

PARAMETERS LIST 47 4PARAMETER COMPLETE PATH SHC PT VALUE SW Release (Read-only) /Comms/Ethernet /System/Sw_release 91 2 Length: 0 to 10 MAC Addres

Strany 48

SC6000 HOST MODE PROGRAMMING 48 4 PARAMETER COMPLETE PATH SHC PT VALUE Phase Echo /Comms/Ethernet /Services/EthernetIP /IO/In/PhaseEcho 295 1 0

Strany 49

PARAMETERS LIST 49 4PARAMETER COMPLETE PATH SHC PT VALUE Max Conveyor Speed Percent Error (%) /Comms/Ethernet /Services/SentinelClient /ConvSpeedChe

Strany 50

SC6000 HOST MODE PROGRAMMING 50 4 PARAMETER COMPLETE PATH SHC PT VALUE Protocol /Comms/Ethernet /Services/UserSocket#N /Protocol 137 1 0 = TCP 1

Strany 51

PARAMETERS LIST 51 4PARAMETER COMPLETE PATH SHC PT VALUE Heartbeat /Comms/ProfiBus /Heartbeat - 1 0 = Disable 1 = Enable Unconditioned 2 = Enable

Strany 52

SC6000 HOST MODE PROGRAMMING 52 4 PARAMETER COMPLETE PATH SHC PT VALUE ADDITIONAL ETHERNET / LINE PARAMETERS (Only -1230 Models) Status /Comms/Eth

Strany 53

PARAMETERS LIST 53 4PARAMETER COMPLETE PATH SHC PT VALUE ADDITIONAL ETHERNET / SERVICES / WEBSENTINEL CLIENT Enable /Comms/Ethernet1 /Services/Sent

Strany 54

SC6000 HOST MODE PROGRAMMING 54 4 PARAMETER COMPLETE PATH SHC PT VALUE Heartbeat Terminator String /Comms/Ethernet1 /Services/UserSocket#N /Heartb

Strany 55

PARAMETERS LIST 55 4PARAMETER COMPLETE PATH SHC PT VALUE 5 = Australia 6 = Bolivia 7 = Bosnia-Herzegovina 8 = Brazil 9 = Brunei 10 = Bulgaria 11 = C

Strany 56

SC6000 HOST MODE PROGRAMMING 2 2 2 PROGRAMMING COMMANDS 2.1 CONNECTION TO DEVICE DESCRIPTION HOST COMMAND REPLY MESSAGE 1 Enter Host Mode

Strany 57

SC6000 HOST MODE PROGRAMMING 56 4 PARAMETER COMPLETE PATH SHC PT VALUE 58 = Senegal 59 = Serbia 60 = Singapore 61 = SlovakRep 62 = Slovenia 63 = S

Strany 58

PARAMETERS LIST 57 4PARAMETER COMPLETE PATH SHC PT VALUE DIGITAL OUTPUT LINES / OUTPUT 1 Use /IO/Out/Out0/Use - 1 1 = Local 2 = Built-in Ethernet

Strany 59

SC6000 HOST MODE PROGRAMMING 58 4 PARAMETER COMPLETE PATH SHC PT VALUE Activation Event /IO/Out/Out1/Active 24 1 0 = None 1 = Complete Read 2 =

Strany 60 - 4.5 DIGITAL I/O SETTING

PARAMETERS LIST 59 4PARAMETER COMPLETE PATH SHC PT VALUE Alternative Activation Event /IO/Out/Out2/Active1 1 0 = None 1 = Complete Read 2 = Parti

Strany 61

SC6000 HOST MODE PROGRAMMING 60 4 PARAMETER COMPLETE PATH SHC PT VALUE Deactivation Event /IO/Out/Out3/Deactive - 1 0 = None 7 = Timeout 5 = Ph

Strany 62

PARAMETERS LIST 61 4PARAMETER COMPLETE PATH SHC PT VALUE Activate On Error /IO/Out/Out4 /ActiveDiagnoErr - 1 0 = Disable 1 = Any Diagnostic Error

Strany 63

SC6000 HOST MODE PROGRAMMING 62 4 PARAMETER COMPLETE PATH SHC PT VALUE Deactivation Timeout (ms) /IO/Out/Out5/Timeout - 0 Range: 40 to 15000 RE

Strany 64

PARAMETERS LIST 63 4PARAMETER COMPLETE PATH SHC PT VALUE Alternative Activation Event /IO/Relays/Relay1 /Active1 - 1 0 = None 1 = Complete Read 2 =

Strany 65

SC6000 HOST MODE PROGRAMMING 64 4 PARAMETER COMPLETE PATH SHC PT VALUE Activate On Error /IO/Relays/Relay2 /ActiveDiagnoErr - 1 0 = Disable 1 =

Strany 66

PARAMETERS LIST 65 4PARAMETER COMPLETE PATH SHC PT VALUE PackTrack Debug Message Digital Input /Diagno/PkTrDbg_Input - 1 0 = None 1 = PS 3 = PSAU

Strany 67

PROGRAMMING COMMANDS 3 22.2 DISCONNECTION FROM DEVICE DESCRIPTION HOST COMMAND REPLY MESSAGE 1 Exit Programming Mode <ESC> d M <B0H&g

Strany 68 - 4.7 DIAGNOSTICS

SC6000 HOST MODE PROGRAMMING 66 4 PARAMETER COMPLETE PATH SHC PT VALUE Presence Sensor Stuck Timeout /Diagno/PSStuck - 1 0 = Disable 1 = 1 sec

Strany 69

PARAMETERS LIST 67 4PARAMETER COMPLETE PATH SHC PT VALUE Message Position /Diagno/Actions /SyncOpt - 1 0 = Append to Code 1 = Replace Code Aux /Di

Strany 70

SC6000 HOST MODE PROGRAMMING 68 4 PARAMETER COMPLETE PATH SHC PT VALUE DIAGNOSTICS / SIMATIC RBS HYBRID SYSTEM ALARMS RFID System Connection Alarm

Strany 71

PARAMETERS LIST 69 4Encoder Event Failure Filter /RedsPar/SwitchPar /EncoderFilterValue - 0 Range: 1 to 10 Check Max Consecutive Lost Parcels /Reds

Strany 72 - 4.8 REDUNDANCY

SC6000 HOST MODE PROGRAMMING 70 4 PARAMETER COMPLETE PATH SHC PT VALUE Header /ES/ESAD/MainPar /ADStrMain - 3 Length: 0 to 1 Terminator /ES/ESAD/

Strany 73 - 4.9 ENERGY SAVING

PARAMETERS LIST 71 4PARAMETER COMPLETE PATH SHC PT VALUE Activation String ES/ESAD/ADAddEth /ADUserSocket#N /ADActStringAddSock - 2 Length: 0 to 1

Strany 74

SC6000 HOST MODE PROGRAMMING 72 A A SPECIAL COMMANDS AND TABLES CONTROL RULES TABLE This paragraph provides a list of the most important contro

Strany 75

SPECIAL COMMANDS AND TABLES 73 APARAMETER CONTROL RULES DATA COMMUNICATION SETTING Host Application Protocol Type Must be  Crisplant if Operating

Strany 76 - CONTROL RULES TABLE

SC6000 HOST MODE PROGRAMMING 74 A ERROR CODES TABLE This paragraph provides a list of the most important error codes. CODE INTERPRETATION COMMA

Strany 77 - SPECIAL COMMANDS AND TABLES

SPECIAL COMMANDS AND TABLES 75 AASCII TABLE CHARACTER TO HEX CONVERSION TABLE CHAR HEX CHAR HEX CHAR HEX NUL 00 * 2A U 55 SOH 01 + 2B V 56 STX 02

Strany 78 - ERROR CODES TABLE

SC6000 HOST MODE PROGRAMMING 4 2 2.3 SELF DISCONNECTION Specific situations exist where the device is automatically disconnected from the Host and

Strany 79 - ASCII TABLE

www.automation.datalogic.com

Strany 80

PROGRAMMING COMMANDS 5 2 HOST DEVICE <ESC> [ C (Enter Host Mode) <ESC> H <CR><LF> <ESC> ] B (Enter Terminal Mode)<E

Komentáře k této Příručce

Žádné komentáře