PARAMETERS LIST
53
4
PARAMETER COMPLETE PATH SHC PT VALUE
ADDITIONAL ETHERNET / SERVICES / WEBSENTINEL CLIENT
Enable /Comms/Ethernet1
/Services/SentinelClient
/Enable
- 1 0 = Disable
1 = Enable
WebSentinel Socket /Comms/Ethernet1
/Services/SentinelClient
/SentinelSocket
- 1 0 = Socket 1
1 = Socket 2
2 = Socket 3
Conveyor Speed
Check Type
/Comms/Ethernet1
/Services/SentinelClient
/ConvSpeedCheck
/ConvSpeedCheckType
- 1 0 = Percent
1 = Absolute
Max Conveyor Speed
Percent Error (%)
/Comms/Ethernet1
/Services/SentinelClient
/ConvSpeedCheck
/MaxConvSpeed
PercentError
- 0 Range: 0 to 20
Max Conveyor Speed
Absolute Error (mm/s)
/Comms/Ethernet1
/Services/SentinelClient
/ConvSpeedCheck
/MaxConvSpeedAbs
Error
- 0 Range: 0 to 3000
Input timeout (secs) /Comms/Ethernet1
/Services/SentinelClient
/InputCheck
/InputTimeOut
- 0 Range: 3 to 10
Send
Autoconfiguration
Message
/Comms/Ethernet1
/Services/SentinelClient
/SentineAuto
configurationMessage1
- 1 0 = Disable
1 = Enable
Send Extended
Parcel Message
/Comms/Ethernet1
/Services/SentinelClient
/SentinelExteNded
Parcel1
- 1 0 = Disable
1 = Enable
ADDITIONAL ETHERNET / SERVICES / USER SOCKET #N (DEPTH: N = 1 to 3)
Status /Comms/Ethernet1
/Services/UserSocket#N
/Status
656 1 0 = Disable
1 = Enable
Data Tx /Comms/Ethernet1
/Services/UserSocket#N
/Sock
- 1 0 = Disable
1 = Enable
Heartbeat /Comms/Ethernet1
/Services/UserSocket#N
/Heartbeat
- 1 0 = Disable
1 = Enable Unconditioned
2 = Enable Conditioned
Heartbeat Timeout /Comms/Ethernet1
/Services/UserSocket#N
/HeartbeatTimeOut
- 0 Range: 5 to 3600
Heartbeat Header
String
/Comms/Ethernet1
/Services/UserSocket#N
/heartbeatStart
- 3 Length: 0 to 32