PROGRAMMING STRINGS
17
3
The 'Restore Default Configuration' programming command must have the following
format:
SD<space>DEFNUM<CR><LF>
Where:
SD:
Restore Default configuration command
DEFNUM:
Default configuration number. The only possible value is currently:
0 = Factory Default
After entering this command, the device responds with the proper reply message and then
waits for one or more programming strings.
If the programming is correct, the device updates the configuration and confirms with the
following message:
Y<space>DEFNUM<CR><LF>
Where:
DEFNUM:
Default
If programming contents are wrong (i.e. a typing error in the file) or due to a transmission
error, the device replies with the following message:
N<space>ERRCODE<CR><LF>
Where:
ERRCODE:
Error Code (signed DEC value)
For information on Error Codes see the "Error Codes Table" in the Appendix.
CAUTION
This programming command will be applied to all Configuration and
Environmental parameters. Refer to the Genius
Help On Line of the
selected device for further details.