SC6000 HOST MODE PROGRAMMING
16
3
3.5 SAVE AND RESTORE COMMANDS
The 'Data Storage' programming command must have the following format:
E<space>MODE<CR><LF>
Where:
E:
Data Storage command.
MODE:
Data Storage mode. The possible values are:
V = Storage in temporary (volatile) memory only.
P = Storage in temporary and permanent memory.
If the programming is correct, the device updates the configuration and confirms with the
following message:
Y<space>MODE<CR><LF>
Where:
MODE:
Data Storage mode.
CAUTION
Restart of the device is now forced. If no disconnection commands are sent
within a minimum timeout of 300 ms, the device will transmit the Self
Disconnection message (refer to the Paragraph 2.3).
If programming contents are wrong (i.e. a typing error in the file) or due to a transmission
error, the device replies with the following message and programming data will not be
updated in this case:
N<space>ERRCODE<CR><LF>
Where:
ERRCODE:
Error Code (signed DEC value).
For information on Error Codes see the "Error Codes Table" in the Appendix.