Datalogic POWERSCAN PBT7100 guide Manuál s instrukcemi Strana 173

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 272
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 172
Interleaved 2 of 5
Product Reference Guide 6-57
Interleaved 2 of 5 — continued
Interleaved 2 of 5 Length 1, Length 2 Pro-
gramming Instructions
1. Scan the START/END bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
3. Turn to
Appendix C, Alpha-Numeric Pad and scan the three digits
(zero padded) representing the length in decimal notation
.
4. Scan the START/END bar code.
NOTE
For Interleaved 2 of 5 bar codes, lengths must
be an even number. Additionally, all check and
data characters are included in the length calcu-
lations.
START/END
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 006
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
050 decimal
Zobrazit stránku 172