Transmit Labels in Code 39 Format
Product Reference Guide
93
Transmit Labels in Code 39 Format
This feature enable/disables translation to Code 39 before transmitting label data to an
IBM-46XX or a USB-OEM host. Only the symbology identifier is modified for the
translation. The data is not converted to Code 39 or verified to be valid for Code 39.
Options are:
IBM Standard Format —
Send labels in standard IBM format.
Code 39 Format —
Translate the following symbologies to Code 39:
USB-OEM: Code128, Code 93, and Codabar
IBM-Port 5B: Code 128, Code 93, and Codabar
IBM-Port 9B: Code 93 and Codabar
ENTER/EXIT PROGRAMMING MODE
Transmit Labels in Code 39 Format = IBM Standard Format
Transmit Labels in Code 39 Format = Code 39 Format
DEFAULT