Data Editing
104 PowerScan® PBT7100 Cordless
Label ID — continued
Table 18. Label ID Examples
STEP ACTION EXAMPLES
1. Scan the ENTER/EXIT barcode (Scanner enters Programming Mode)
2.
Determine placement of the Label
ID characters BEFORE or AFTER
with regard to scanned data using
Label ID Control on
page 105
Enable as Prefix Enable as Suffix Enable as Prefix Enable as Suffix
3.
Scan the barcode selecting the
symbology type you wish to
designate label ID characters for
using
Label ID Symbology
Selection, starting on page
106
.
GS1 DataBar
Omnidirectional
Code 39 Interleaved 2 of 5 Code 32
4.
Custom Label ID example (desired
characters):
D B * = C 3 +P H
5.
Find hex equivalents from the
ASCII table (inside back cover),
then scan in these digits/
characters using the barcodes in
the section:
Keypad, starting
on page 323
. f you make a
mistake before the last character,
scan the CANCEL barcode to
abort and not save the entry
string. You can then start again at
the beginning.
44 42 2A 3D 43 33 2B 50 48
6. Scan theENTER/EXIT barcode (Scanner exits Label ID entry)
7.
Scan the ENTER/EXIT barcode
once again
(Scanner exits Programming Mode)
Result:
DB*[barcode data] [barcode data]=C3 +[barcode data] [barcode data]PH
Zobrazit stránku 113