BT Security Features
Product Reference Guide
291
Batch Features — cont.
Send Batch
Use this barcode to initiate sending of labels stored in batch memory.
Erase Batch Memory
Use this barcode to erase any labels stored in batch memory.
BT Security Features
These features enable/disable the BT system to require a configurable pin code to authen-
ticate/connect the BT devices, and encrypt the data.
BT Pin Code
This option specifies the 4-character pin code to be used for authentication of the BT
link. BT Security Mode on page 294 must be enabled in order to require the pin
code.
To set the pin code:
1. Determine the desired characters. For example, D254.
2. Convert the characters to hexidecimal using the ASCII Chart on the inside back cover
of this manual. In the case of the example, the hexidecimal equivalents would be:
D = 0x44, 2 = 0x32, 5 = 0x35, and 4 = 0x34
NOTE
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with
this barcode.
Send Batch
NOTE
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with
this barcode.
Erase Batch Memory